Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 5521 - 5540 of 41651
PDF[9419059-7C] K8AB-VS measuring & monitoring relay ...

...Load (P Level) DC5V, 10mA *Reference value Mechanical Life 10 million times minimum Recommended Cable Diameter Recommended Crimp Terminal AI 1,5-8BK (Phoenix Contact product) AWG#16 AI 1-8RD ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k8ab-vs(oldtype)_inst-9419059-7c.pdf

PDF[9419059-7E] K8AB-VS Measuring & Monitoring Relay ...

...5 min × 10 scanning Input Range Terminals V1, V2, V3 ALM Recommended Crimp Terminal Recommended Cable Diameter AI 1,5-8BK (Phoenix Contact product) AWG#16 AI 1-8RD (Phoenix Contact product) A...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k8ab-vs_inst-9419059-7e.pdf

PDFInstructions Manual Model 61F-D21T-V1

...ft the unit from the bottom. ●Recommended Crimp Terminal Recommended Crimp Terminal Recommended Cable Diameter AWG#16 AWG#18 AWG#18 AI 1,5-8BK (Phoenix Contact product) AI 1-8RD (Phoenix Cont...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/61f-d21t-v1_inst-0943893-3c.pdf

PDFInstructions Manual Model 61F-D21T-V1

...ft the unit from the bottom. ●Recommended Crimp Terminal Recommended Crimp Terminal Recommended Cable Diameter AWG#16 AWG#18 AWG#18 AI 1,5-8BK (Phoenix Contact product) AI 1-8RD (Phoenix Cont...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/61f-d21t-v1_inst-9419049-0b.pdf

PDFINSTRUCTION SHEET Precaution for Compliance with U...

... Compliance with UL Standards Notice to Users of the components in USA and Canada Communication cable Wire range Wire size 26AWG 1 Amp 2 Amp 3 Amp 5 Amp 7 Amp 8 Amp 24AWG 22AWG 20AWG 18AWG 16...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/grt1-drt(precautionsforulcsastandards)_inst-0675654-3b.pdf

PDFINSTRUCTION SHEET Precaution for Compliance with U...

...for Compliance with UL Standards Notice to Users of the components in USA and Canada Connection cable (GCN2-100) Model Wire size 26 AWG 1 Amp 2 Amp 3 Amp 5 Amp 7 Amp 8 Amp 24 AWG 22 AWG 20 AW...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/grt1series(precautionsforulcsastandards)_inst-0675843-0c.pdf

Safety Precautions of Solid-state Relays Cautions ...

...han the must release voltage of the SSR. Twisted-pair wires: For electromagnetic noise Shielded cable: For static noise A filter consisting of a combination of capacitor and resistor will eff...

https://www.ia.omron.com/product/cautions/18/safety_precautions.html

Safety Precautions of Timers Cautions for Timers |...

... the top and bottom sides. When using the US08, be sure to use 10.5-mm-dia. max. multiconductor cable or 3-mm-dia. max. insulated stranded wire for wiring. When the Y92F-40, Y92F-70, Y92F-71,...

https://www.ia.omron.com/product/cautions/19/safety_precautions.html

Safety Precautions of Power Supplies Cautions for ...

...l diagrams for each model for specific dimensions. Wiring Use caution when connecting the input cable to the Power Supply. The Power Supply Unit may be destroyed if the input cable i...

https://www.ia.omron.com/product/cautions/22/safety_precautions.html

Safety Precautions of Photomicro Sensors Cautions ...

...odels that begin with EE-SP), the design must take into account the effects of power source and cable length. Photomicrosensors with Modulated Light are more easily affected than Photomicrose...

https://www.ia.omron.com/product/cautions/24/safety_precautions.html

Safety Precautions of Limit Switches Cautions for ...

...etrate into the Switch through the conduit opening. Be sure to attach a connector suited to the cable thickness and tighten the connector securely to the rated torque. Do not impose shock or ...

https://www.ia.omron.com/product/cautions/30/safety_precautions.html

Safety Precautions of Rotary Encoders Cautions for...

...in the following graphs (theoretical value). E6B2-C E6C2-C[] E6C3-C[]H Wiring If connecting the cable after securing the Encoder, do not pull on the cable with a force of 29.4 N or g...

https://www.ia.omron.com/product/cautions/34/safety_precautions.html

Safety Precautions of Proximity Sensors Cautions f...

...ample: E2E-X[]D[]-U) Table 3: AC 2-wire Table 4: DC 3-wire NPN Table 5: DC 3-wire PNP Extending Cable Length The cable of a Built-in Amplifier Sensor can be extended to a maximum len...

https://www.ia.omron.com/product/cautions/41/safety_precautions.html

Safety Precautions of Photoelectric Sensors Cautio...

...oise filter (e.g.,ferrite core or insulated transformer), or varistor in the power line. Wiring Cable Unless otherwise indicated, the maximum length of cable extension is 100 m using...

https://www.ia.omron.com/product/cautions/43/safety_precautions.html

Safety Precautions of Axial Fans Cautions for Axia...

...ct label. 7. When using the following model, ensure EMC conformity by using a power supply line cable no longer than 30 m. In addition, do not connect to a DC distribution network. Applicable...

https://www.ia.omron.com/product/cautions/45/safety_precautions.html

Safety Precautions of Digital Panel Indicators Cau...

...rom power lines carrying high voltages or currents. Do not wire in parallel with or in the same cable as power lines. Other measures for reducing noise include running lines along separate du...

https://www.ia.omron.com/product/cautions/62/safety_precautions.html

Safety Precautions of Signal Converters Cautions f...

...rom power lines carrying high voltages or currents. Do not wire in parallel with or in the same cable as power lines. Other measures for reducing noise include running lines along separate du...

https://www.ia.omron.com/product/cautions/63/safety_precautions.html

E32 Series Fiber Sensors/Features | OMRON Industri...

...le drilled in a bracket and secured with nuts. • The Right-angle Model prevents snagging on the cable because the cable runs along the mounting surface. Hex-shaped Models • You can e...

https://www.ia.omron.com/products/family/1532/application.html

ZX2 Smart Sensors Laser Displacement Sensors CMOS ...

...t for Various Environments/Space-Saving Reliable measurements in harsh environments IP67, robot cable & temperature characteristic 0.02% F.S./°C IP67 protection class enables to use the senso...

https://www.ia.omron.com/products/family/2979/application.html

E3AS-HF Series TOF Laser Sensor with Built-in Ampl...

...do not obstruct their movement. Thus remove failure risks such as optical axis displacement and cable disconnection due to collision with a workpiece, and ensure stable sensing when the targe...

https://www.omron.com.tw/products/family/3926/

Results 5521 - 5540 of 41651

Select Country in