Site Search | Product Search | IA Global Search |
...ng of process value in industrial units, process value alarm setting (L, H), inrush input upper limit, inrush input upper limit time, zero/span adjustment value, Square root function...
https://www.omron-ap.co.th/products/family/1665/specification.html
...words/Unit CPU Unit to Analog Output Unit: Output hold for when CPU Unit error occurs, high/low limit values, rate-of-change limit values (positive and negative directions), number o...
https://www.omron-ap.co.th/products/family/1669/specification.html
... sensors that are the pulse sources. Output voltage: 12 V DC ± 15% Current capacity: 30 mA max. Limit current when short-circuited: 31 to 55 mA Allowable short-circuit time: No limit...
https://www.omron-ap.co.th/products/family/1671/specification.html
...CPU Unit's I/O memory, the collected values can be scaled with a linear equation or upper/lower limit range before storage (unit version 1.2 or later). File size 2 GB per file Record size Spe...
https://www.omron-ap.co.th/products/family/1732/specification.html
..., display reverse, scaling, peak and bottom hold, distance compensation, present value display, limit number of display digits, monitor focus, mask hold, sensing area compensation, output val...
https://www.omron-ap.co.th/products/family/1736/specification.html
...fier sets the resistance for detection within the setting range. It is factory-set to the upper limit. (Normally, the K7L can be used with the adjuster at this setting.) Disconnection detecti...
https://www.omron-ap.co.th/products/family/1819/specification.html
...20A ZX-XGC20R Note: Up to two extension cables can be connected. However, be sure to limit the total extension cable length between the receiver and the Controller to 30 meters ...
...Transmission distance 100 m (distance between hub and node) No. of cascade-connectable Units No limit when a switching hub is used. last update: December 1, 2020...
https://www.omron-ap.co.th/products/family/1922/specification.html
...C Transistor (Photocoupler) 24 to 48 VAC (50/60 Hz)/ 12 to 48 VDC 0.05 s to 300 h H3CR-A8S Time-limit contact and instantaneous contact 100 to 240 VAC (50/60 Hz)/ 100 to 125 VDC H3CR-A8E 24 t...
...t (power supply start) Pin type 11-pin 8-pin Input type No-voltage input Voltage input --- Time-limit output type H3CR-A/-A8/-AP/-A-301/-A8-301: Relay output (DPDT) H3CR-AS/-A8S: Transistor o...
https://www.omron-ap.co.th/products/family/193/specification.html
... modes --- Input mode: Not 2-input independent measurement: Upper and lower limits, area, upper limit, lower limit. 2-input independent measurement: Upper limit, lower ...
https://www.omron-ap.co.th/products/family/1931/specification.html
...icker OFF start Flicker ON start Pin type 11-pin 8-pin 11-pin 8-pin Operating/Reset method Time-limit operation/Time-limit reset or self-reset Output type Relay output (DPDT) Mountin...
https://www.omron-ap.co.th/products/family/194/specification.html
...hing Supported (number of banks: 8) Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.) Other functions Manual output, heating/cooling control, l...
https://www.omron-ap.co.th/products/family/1946/specification.html
...hing Supported (number of banks: 8) Local SP, alarm settings, PID sets (PID constants, MV upper limit, MV lower limit, etc.) Other functions Manual output, heating/cooling control, l...
https://www.omron-ap.co.th/products/family/1947/specification.html
...o 5 V, 0 to 10 V) Detection level Temperature input: If the temperature exceeds the high or low limit of the sensor range by 20°C or 20°F. +1 to +5 V: input signal ...
https://www.omron-ap.co.th/products/family/1988/specification.html
...setting 0.0% to 100% Base-up value 0.0% to 100% (Default: 0.0%) Upper/lower limits Output upper limit: 0.0% to 100% (Default: 100%) Output lower limit: 0.0% to 100% (Default: 0.0%) D...
https://www.omron-ap.co.th/products/family/2011/specification.html
...D / Software last update: May 8, 2018 Operation/ resetting system Operation mode Terminal Time- limit contact Instan- taneous contact Mounting Surface mounting/ track mounting Flush mounting ...
...present command position, but also the present position from the feedback pulse counter. Torque limit output An output signal is available for operating the torque limit switch input...
https://www.omron-ap.co.th/products/family/2051/specification.html
...: Flicker ON Start 2 Screw terminals Signal, Reset, Gate (NPN/ PNP inputs) Contact output (time-limit SPDT) 100 to 240 VAC H5CX-A-N 12 to 24 VDC/ 24 VAC H5CX-AD-N Transistor output (SPST) 100...
...rad/s 2 30,000 max. (Speed of 2,800 r/min or more must not be changed in less than 10 ms) Brake limit - 10 million times min. Rating - Continuous Insulation class - Type F *1. These are the v...
https://www.omron-ap.co.th/products/family/2611/specification.html