Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 601 - 620 of 1264
PDFN227-E1-07 User's Manual K7TM Troubleshooting

... •Variations in CTs are not included. Repeat accuracy of resistance value (reference value):±1% rdg±1 digit Conditions: •When sine waves are input continuously •Variations in CTs are not incl...

https://www.fa.omron.com.cn/data_pdf/mnu/n227-e1-07_k7tm.pdf

PDFN233-E1-04 User's Manual K7DD Power Line Data Gene...

...y (Ambient temperature: 10 to 30°C) Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy:±1%rdg±1digit •Not including accuracy variation of CTs •The power frequency must be within the rat...

https://www.fa.omron.com.cn/data_pdf/mnu/n233-e1-04_k7dd.pdf

PDF电机状态监视器用户手册 用户手册 K6CM 电机状态监视器 通过支持EtherNet/IP的设备

...61010-030) EMC:EN61326-1(EMI:ClassA EMS:Indutrial Location) 加速度:±0.1G、速度±2.25mm/s、温度±6℃、绝缘电阻±35%rdg、电流 ±10%F.S. 安全标准:UL61010-2-030(Listing)、韩国电波法、RCM 安...

https://www.fa.omron.com.cn/data_pdf/mnu/sgte-cn5-720p.pdf

PDFSGTE-CN5-724B 用户手册 K7TM 加热器状态监视器

...流测量精度:相对于输入范围±0.5 %FS±1 digit [条件] •正弦波连续输入时 •不包含CT的精度偏差电阻值重复精度(参考值):±1 %rdg±1 digit [条件] •正弦波连续输入时 •不包含CT的精度偏差测量对象电阻加...

https://www.fa.omron.com.cn/data_pdf/mnu/sgte-cn5-724b.pdf

PDFSGTE-CN5-726A 用户手册 K7DD 电力线数据生成器

... V范围:300.0~600.0 V 驱动频率45~245 Hz对于正弦波测量精度 (环境温度10~30℃) 电流绝对精度:±0.5 %FS±1 digit 重复精度:±1 %rdg±1 digit •不包含CT的精度偏差 •驱动频率在额定范围内电压绝对精度...

https://www.fa.omron.com.cn/data_pdf/mnu/sgte-cn5-726a.pdf

PDFS8AS Smart Power Supply USER'S MANUAL

.... Display func- tions Output voltage display Display range: 17.0 to 30.0 V Display accuracy: 2% rdg±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output c...

https://www.fa.omron.com.cn/data_pdf/mnu/z269-e1-07_s8as.pdf

PDFInfrared Thermosensor ES1-N Measure Workpieces wit...

...mption 30 mA max. (24 VDC) Cable length 2 m ±5 cm Measurement accuracy USB output • Within ±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) • Within ±1°C (0 to 200°C) • Within ±0.5%...

https://www.omron-ap.co.in/data_pdf/cat/es1-n_h227-e1_4_4_csm1059198.pdf

PDFWeighing Indicator K3HB-V CSM_K3HB-V_DS_E_11_6

...nge Input impedance 1 MΩ min. Accuracy A a lc 0.00 to 199.99 mV B b lc 0.000 to 19.999 mV ±0.1% rdg ±1 digit max. ±0.1% rdg ±5 digits max. C c lc ±100.00 mV ±0.1% rdg ±3 dig...

https://www.omron-ap.co.in/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf

PDFProcess Indicator K3HB-X CSM_K3HB-X_DS_E_12_6

...to 19.999 mA 0.000 to 21.999m A 10 Ω max. K3HB-XAD DC current K3HB-XAA AC current Accuracy ±0.1%rdg ± 1 digit max. ±0.1%rdg ± 1 digit max. Allowable instantaneous overload (30 s) ±40...

https://www.omron-ap.co.in/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf

PDFMotor Condition Monitoring Device

...etting value Hysteresis Reset method LCD display Conforming standards Applicable standards ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩ max.), when a 200-V/7.5-kW max. motor is ...

https://www.omron-ap.co.in/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf

PDFMotor Condition Monitoring Device

...etting value Hysteresis Reset method LCD display Conforming standards Applicable standards ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩ max.), when a 200-V/7.5-kW max. motor is ...

https://www.omron-ap.co.in/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf

PDFAdvanced Motor Condition Monitoring Device

... frequency 45 to 245 Hz Since wave Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...

https://www.omron-ap.co.in/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDFInsulation Resistance Monitoring Device

...fications Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger volta...

https://www.omron-ap.co.in/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf

PDFHeater Condition Monitoring Device

...e not included. Measurement accuracy Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...

https://www.omron-ap.co.in/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDFDigital Multicircuit Protector

...dual voltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current ...

https://www.omron-ap.co.in/data_pdf/cat/s8m_t232-e1_3_4_csm2006.pdf

PDF:arQLQJ6\PEROV Precautions fRU6DfH8VH 6SHFLILFDWLR...

... 1O7 86E + 4 transfer output 5 - 5 Event Inputs and Transfer output EV EV + 4-20 mADC transfer /RDGŸPD[ output 4 5 - 4-20 mADC /RDGŸPD[ ‡ $KHDWHUEXUQRXWDODUPKHDWHUVKRUWDODUPKHDWHURYH...

https://www.omron-ap.co.in/data_pdf/mnu/e5cn-h_inst-5639658-0a.pdf

PDF●仕様 形 ES1-L-N 注意 形式 形ES1-LP3-N/形ES1-LP10-N

...す。 パソコンと接続するためのマイクロUSBケーブルは、お客様でご準備ください。 取付金具 2m アルミニウム rdg:読み取り値 *1:電流出力4∼20mAは、 すべて0∼500℃でスケーリングしています。 出荷時のス...

https://www.omron-ap.co.in/data_pdf/mnu/es1-l_(l)-n_inst-gz0000492904.pdf

PDF(16)フロントシートの剥がれ・破れが生じた状態で使用しないで 取り付け方法

...イン Plus 黒(マンセル N1.5) DIN レールメインユニット:約 156g プローブユニット:約 63g 0.1 ∼ 99.9MΩ(0.1MΩ未満は 0.0MΩ) ±5%rdg±1digit (周囲温度 -10 ∼ 55℃、周囲湿度 25 ∼ 65%RH) 操作電源:...

https://www.omron-ap.co.in/data_pdf/mnu/k7ge-mg_inst-5641253-5a.pdf

PDF1 Overview 2 Device Components Motor Condition 3

... Acceleration: ± 0.1 G, velocity: ± 2.25 mm/s, temperature: ± 6°C, insulation resistance: ± 35% rdg., current: ± 10% F. S. Safety standards: UL 61010-2-030 (Listing), CSA*1, Korean Radio Law,...

https://www.omron-ap.co.in/data_pdf/mnu/n219-e1-16_k6cm.pdf

PDF1 Overview 2 Procedure Insulation Resistance 3

....9 MΩ. 0.1 0.0 0.1 M 1M 10 M 99.9 M Measurement value The measuring accuracy is as follows: ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) "...

https://www.omron-ap.co.in/data_pdf/mnu/n224-e1-07_k7ge-mg.pdf

Results 601 - 620 of 1264