Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 6201 - 6220 of 12242
PDF[N194-E1-03] K8DS-PZ Catalog

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.co.jp/data_pdf/cat/k8ds-pz_n194-e1_2_6_csm1020924.pdf

PDF[N201-E1-02] K8DT-AS Data Sheet

...etting range (T) 0.1 to 30 s Startup lock time setting range (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-as_n201-e1_1_9_csm1050137.pdf

PDF[N202-E1-02] K8DT-AW Data Sheet

...etting range (T) 0.1 to 30 s Startup lock time setting range (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-aw_n202-e1_2_2_csm1050138.pdf

PDF[N205-E1-02] K8DT-LS Data Sheet

...t Conductive Level Controller K8DT-LS Ideal for water level control. Sensitivity adjustment and timer for easy usage. • Sensitivity adjustment from 10 k to 100 kΩ. • Enables easy onsite adjus...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-ls_n205-e1_1_8_csm1050141.pdf

PDF[N207-E1-02] K8DT-PM Data Sheet

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-pm_n207-e1_1_9_csm1050143.pdf

PDF[N208-E1-02] K8DT-PZ Data Sheet

...ed ON. There is no voltage becomes very low, the indicator will turn OFF. contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-pz_n208-e1_1_9_csm1050144.pdf

PDF[N203-E1-02] K8DT-VS Data Sheet

...during the instable period when the power is first turned on. There is no contact output during timer operation. t: Operating time (0.1 to 30 s) t t1: Power ON lock (1 or 5 s) Note: The power...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-vs_n203-e1_1_8_csm1050139.pdf

PDF[N204-E1-02] K8DT-VW Data Sheet

...d during the instable period when the power is first turned on. There is no relay output during timer operation. Overvoltage and Overvoltage Operation Diagram Lit t Contacts 11-14 or transist...

https://www.fa.omron.co.jp/data_pdf/cat/k8dt-vw_n204-e1_1_10_csm1050140.pdf

PDF[-] NE1A-SCPU0[]-EIP Data Sheet

...ring RS Flip-flop RS-FF Two Hand Controller Two Hand Controller Comparator Comparator Off-Delay Timer Off-Delay Timer On-Delay Timer On-Delay Timer User Mode Switch...

https://www.fa.omron.co.jp/data_pdf/cat/ne1a-scpu0_-eip_ds_e_5_4_csm2129.pdf

PDF[-] NE1A-SCPU Series Data Sheet

...onitoring Safety Gate Monitoring Two-hand Controller Two Hand Controller 1.0 or later Off-Delay Timer Off-Delay Timer On-Delay Timer On-Delay Timer User Mode Switch...

https://www.fa.omron.co.jp/data_pdf/cat/ne1a-scpu_series_ds_e_6_5_csm1273.pdf

PDF[-] S3D2 Data Sheet

...er S3D2 CSM_S3D2_DS_E_7_2 Offers High-speed Input Response of 0.1 ms and Equipped with Built-in Timer • High-speed response of 0.1 ms. • Ideal as a two-input Controller. • Lineup includes the...

https://www.fa.omron.co.jp/data_pdf/cat/s3d2_ds_e_7_2_csm511.pdf

PDFセンサコントローラ S3D2 CSM_S3D2_DS_J_7_5

....1s:設定時間が0.01∼0.1sの範囲となります。 1s :設定時間が0.1∼1sの範囲となります。 O. S :ワンショットタイマ TIMER MODE ⑪ ON. D :ONディレイタイマ (タイマ動作切替スイッチ) OFF. D:OFFディレ...

https://www.fa.omron.co.jp/data_pdf/cat/s3d2_ds_j_7_5.pdf

PDF[T234-E1-04] S8T-DCBU-02 Data Sheet

...ting and Removing the Bus Line Connector Operation Check and Periodic Inspection H5CX-A Digital Timer Pay attention to the following points to maintain electric characteristics. • Do not inse...

https://www.fa.omron.co.jp/data_pdf/cat/s8t-dcbu-02_t234-e1_10_3_csm138.pdf

PDF[-] SAO Data Sheet

...e SV may occur. Motor M Note: To prevent the buzzer sounding when power is turned ON, install a timer so that the buzzer sounds only when the timer’s contacts are closed. 5 SAO Opera...

https://www.fa.omron.co.jp/data_pdf/cat/sao_ds_e_5_4_csm390.pdf

PDF[-] SDV Data Sheet

...C SDV-FH71T OFF-delay Startup lock Note: Only SDV-FH voltage sensors can be manufactured with a timer. Specifications Single-function Models Overvoltage or Undervoltage Detection (Switch Sele...

https://www.fa.omron.co.jp/data_pdf/cat/sdv_ds_e_6_6_csm392.pdf

PDFボルティジ・センサ SDV  CSM_SDV_DS_J_6_15

...INPUT DC ○ ×10V ○ ○ ○ MULTIPLY- ×25V ● ○ ○ ING ×50V ○ ● ○ FACTOR ×100V ○ ○ ● ON DELAY OFF DELAY TIMER LOCK TIMER TIMER OFF OVER FUNCTION INPUT AC NO USE UNDER NO USE INPUT D...

https://www.fa.omron.co.jp/data_pdf/cat/sdv_ds_j_6_15.pdf

PDFRFID System V680 Series RFID Systems with ISO/IEC ...

...* Data transfer quantity 2,048 bytes max. (160 bytes/scan) Diagnostic function (1) CPU watchdog timer (2) Communications error detection with RF Tag (3) Antenna power supply error Monitoring/...

https://www.fa.omron.co.jp/data_pdf/cat/v680 series_q267-e1_1_23_csm1003322.pdf

PDFWatertight Cover Y92A-@@N CSM_Y92A-__N_DS_E_6_6

...r Counter E5@C, E5@N , E5@R , E5@S, E5C2, E5CB H7CX*5, H7CZ*4, H8PS, H7BX, H8BM, H7AN*5, H7CN*4 Timer Digital Panel Meter H3CR, H3CA*3, H5CX*7, H5CZ*6, H5CN*6, H5AN*6 K3HB-X, K3HB-S, K3HB-V, ...

https://www.fa.omron.co.jp/data_pdf/cat/y92a-__n_ds_e_6_6_csm226.pdf

PDFLaser Displacement Sensor ZP- L

...k hold), the bottom value (bottom hold), the range of change (peak-to-peak hold), and so forth. Timer mode Allows you to delay upon changes in judgment output, or turn PASS output ON for a gi...

https://www.fa.omron.co.jp/data_pdf/cat/zp-l_q362-e1_3_1_csm1130069.pdf

PDFSmart Sensor 2D Measurement Type

...aling, various hold values, and zero reset Linear (focus/correction), judgments (hysteresis and timer), non-measurement, and bank (switching and clear) Save, initialization, measurement infor...

https://www.fa.omron.co.jp/data_pdf/cat/zs-n_ds_e_7_2_csm1012042.pdf

Results 6201 - 6220 of 12242

Select Country in