PDFCat. No. W486-E1-02 SYSMAC CJ Series

...onnect pin 6 (5-V power supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 Link Adapter, CJ1W-CIF11 Converter, and Programmable Terminals (NV3WM@20L). The extern...

https://www.omron-ap.com/data_pdf/mnu/w486-e1-02_cj2m-cpu_-md21_.pdf

PDFProgrammable Controller CS1D Duplex System

...*1 --- *1. These values include the current consumption of a connected Programming Console. *2. NT-AL001 Link Adapters consume an additional 0.15 A each when used. Programmable Controllers CS...

https://www.omron.co.id/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_22_csm1004122.pdf

PDFProgrammable Controllers CS Series PLC-based Proce...

...urrent consumption (supplied from Power Supply Unit) 220 mA at 5 V DC (Increased by 150 mA when NT-AL001-E Link Adapter is used.) Dimensions 34.5 × 130 × 100.5 mm (W × H × D) Weight 100g max....

https://www.omron.co.id/data_pdf/cat/plc-based_process_control_p051-e1_9_15_csm2684.pdf

PDF在进行直流电源配线的时候,请注意+/-极性。 ●客户程序、参数区域的数据备份在内置闪存中。备份过程中...

...考手册的指示进行。 ●千万不要将 CPU 单元上 RS-232 口上的引脚 6(5V 电源)与其它设备连接,除非设备上用了转换适配器 CJ1W-CIF11/NT-AL001、可编程终端 NV3W-M□20L。 否则会损坏外部设备或 CPU 单元。 ●...

https://www.omron.co.id/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4029655-1a.pdf

PDFAC 㟁※ࡢ➃Ꮚࡡࡌࡣཧ↷࣐ࢽࣗ࢔࡛ࣝᣦᐃࡋࡓつᐃࢺࣝࢡ࡛⥾ࡵ࡚ࡃ ‫&ە‬38 ࣘࢽࢵࢺ࡟⿦╔ࡋࡓ...

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...

https://www.omron.co.id/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4031560-2b.pdf

PDFP r ogr ammable Contr oller C200H-ser ies

...53/BC052 CS1W-BC083/BC082 CS1W-BC103/BC102 Description UM 10K steps *To replace C120-LK202, use NT-AL001 to convert RS-232C into RS-422. To use RUN output, prepare an Output Unit separately. ...

https://www.omron.co.id/data_pdf/mnu/p069-e1-06_c200h_cs1_replace.pdf

PDFCat. No. W344-E1-18 SYSMAC CX-Protocol Ver. 2.0

...re/4-wire selection switch on the port 2 of RS422A/485 does not match with the wiring. Adapter (NT-AL001, etc.) wiring is faulty. Section 4-7 Errors at the Protocol Execution Serial communica...

https://www.omron.co.id/data_pdf/mnu/w344-e1-18_cx-protocol.pdf

PDFCat. No. W406-E1-10 SYSMAC CS/CJ Series

...he RS-232C port on the CPU Unit to any external device except the CJ1W-CIF11 RS-422A Adapter or NT-AL001 RS-232C/RS-422A Adapter. Doing so may damage the external device or Loop Control Board...

https://www.omron.co.id/data_pdf/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf

PDFCat. No. W486-E1-02 SYSMAC CJ Series

...onnect pin 6 (5-V power supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 Link Adapter, CJ1W-CIF11 Converter, and Programmable Terminals (NV3WM@20L). The extern...

https://www.omron.co.id/data_pdf/mnu/w486-e1-02_cj2m-cpu_-md21_.pdf

PDFProgrammable Controller CS1D Duplex System

...*1 --- *1. These values include the current consumption of a connected Programming Console. *2. NT-AL001 Link Adapters consume an additional 0.15 A each when used. Programmable Controllers CS...

https://www.omron.com.au/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_22_csm1004122.pdf

PDFProgrammable Controllers CS Series PLC-based Proce...

...urrent consumption (supplied from Power Supply Unit) 220 mA at 5 V DC (Increased by 150 mA when NT-AL001-E Link Adapter is used.) Dimensions 34.5 × 130 × 100.5 mm (W × H × D) Weight 100g max....

https://www.omron.com.au/data_pdf/cat/plc-based_process_control_p051-e1_9_15_csm2684.pdf

PDF在进行直流电源配线的时候,请注意+/-极性。 ●客户程序、参数区域的数据备份在内置闪存中。备份过程中...

...考手册的指示进行。 ●千万不要将 CPU 单元上 RS-232 口上的引脚 6(5V 电源)与其它设备连接,除非设备上用了转换适配器 CJ1W-CIF11/NT-AL001、可编程终端 NV3W-M□20L。 否则会损坏外部设备或 CPU 单元。 ●...

https://www.omron.com.au/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4029655-1a.pdf

PDFAC 㟁※ࡢ➃Ꮚࡡࡌࡣཧ↷࣐ࢽࣗ࢔࡛ࣝᣦᐃࡋࡓつᐃࢺࣝࢡ࡛⥾ࡵ࡚ࡃ ‫&ە‬38 ࣘࢽࢵࢺ࡟⿦╔ࡋࡓ...

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...

https://www.omron.com.au/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4031560-2b.pdf

PDFP r ogr ammable Contr oller C200H-ser ies

...53/BC052 CS1W-BC083/BC082 CS1W-BC103/BC102 Description UM 10K steps *To replace C120-LK202, use NT-AL001 to convert RS-232C into RS-422. To use RUN output, prepare an Output Unit separately. ...

https://www.omron.com.au/data_pdf/mnu/p069-e1-06_c200h_cs1_replace.pdf

PDFCat. No. W344-E1-18 SYSMAC CX-Protocol Ver. 2.0

...re/4-wire selection switch on the port 2 of RS422A/485 does not match with the wiring. Adapter (NT-AL001, etc.) wiring is faulty. Section 4-7 Errors at the Protocol Execution Serial communica...

https://www.omron.com.au/data_pdf/mnu/w344-e1-18_cx-protocol.pdf

PDFCat. No. W406-E1-10 SYSMAC CS/CJ Series

...he RS-232C port on the CPU Unit to any external device except the CJ1W-CIF11 RS-422A Adapter or NT-AL001 RS-232C/RS-422A Adapter. Doing so may damage the external device or Loop Control Board...

https://www.omron.com.au/data_pdf/mnu/w406-e1-10_cs1w-lcb_cs1d-cpu_cs1g-cpu.pdf

PDFCat. No. W486-E1-02 SYSMAC CJ Series

...onnect pin 6 (5-V power supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 Link Adapter, CJ1W-CIF11 Converter, and Programmable Terminals (NV3WM@20L). The extern...

https://www.omron.com.au/data_pdf/mnu/w486-e1-02_cj2m-cpu_-md21_.pdf

PDF可程式控制器 CS1D備援系統 簡化CPU、電源、通訊、I/O增設的備援化,

...槽)均為 :505(W)×132(H)×123(D)*2 32可程式控制器CS1D CPU模組型號一覽表 *1.此值包含程序設計模組的消耗電流。 *2.連接NT-AL001型時,1埠加計0.15A CS1D CPU模組 (CPU雙重化系統用) 程序CPU...

https://www.omron.com.tw/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_sbca-014_tw_9_18.pdf

PDFSYSMAC CP系列 安全上的注意事项 感谢您购买本公司的可编程序控制器(PLC)。

...考手册的指示进行。 ●千万不要将CPU单元上RS-232口上的引脚6(5V电源)与其它设备连接,除非设备上用了转换适配器CJ1W-CIF11/NT-AL001、可编程终端NV3W-M□20L。 否则会损坏外部设备或CPU单元。 ●请使用各单...

https://www.omron.com.tw/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4029655-1a.pdf

PDFSYSMAC CPࢩ࣮ࣜࢬ Ᏻ඲ୖࡢࡈὀព ࡇࡢࡓࡧࡣᙜ♫ࡢࣉࣟࢢ࣐ࣛࣈࣝࢥࣥࢺ࣮ࣟࣛ㸦PLC㸧ࢆ࠾...

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...

https://www.omron.com.tw/data_pdf/mnu/cp1w-adb21_-dab21v_-mab221(safetyprecautions)_inst-4031560-2b.pdf