| Site Search | Product Search | IA Global Search |
...to 3736 FJ-SC5MGR: 0 to 12487 FJ-S5MGR: 0 to 12487 (Unit: Tick, FJ-S£ £££ Camera: 1 [Tick] = 8 [ns]) Set the delay time of packets between. Set for preventing packet-loss because of connectin...
https://www.omron-ap.co.th/data_pdf/mnu/z428-e1-03_fj-s__g_fj-sc__g.pdf
...d behind/left and right Fast Transient Burst • DC power: Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...
...on IP20 (IEC60529) Noise immunity 1,500 V peak-to-peak, pulse width 0.1 µs/1 µs, rising edge: 1 ns pulse Vibration resistance (destructive) 10 to 150 Hz, 0.7-mm double amplitude, 80 min each ...
https://www.omron-ap.co.th/data_pdf/mnu/z470-e1-01_zs-hl-n.pdf
...g data links are operating normally. Below is the LED status in normal operation. MS: Lit Green NS: Lit Green COMM: Lit Yellow 100M or 10M: Lit Yellow 2 Check the LED indicators on the code r...
https://www.omron-ap.co.th/data_pdf/mnu/z478-e1-01_v460-h.pdf
...ction Error Green/Red Flashing Initializing --- Not lit The Unit/input power is not supplied. l NS Indicator The network status indicator. This indicator shows the status of the EtherNet/IP n...
https://www.omron-ap.co.th/data_pdf/mnu/z496-e1-02_zp-eip.pdf
...LED indicators in normal status are as follows: U/IN PWN: Green lit MS: Green lit SS: Green lit NS: Green lit L/A ETH1: Green lit / Green flashing (Flashing while packets are being sent and r...
https://www.omron-ap.co.th/data_pdf/mnu/z501-e1-01_zp-eip.pdf
...ft/right) Noise immunity Fast transient burst • DC power Direct infusion: 2 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst continuation time: 15 ms/0.75 ms, Period: 300 ms, Applic...
https://www.omron-ap.co.th/data_pdf/mnu/z507-e1-02_fhv7x-c016-s__-w-01.pdf
...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.35-mm amplitude, 80 min each in X, Y, and Z directions 150m/s2 3 times...
https://www.omron-ap.co.th/data_pdf/mnu/zg2-dsu___inst-1668182-7c.pdf
...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300m/s2 3...
https://www.omron-ap.co.th/data_pdf/mnu/zs-dsu___inst-7934186-4g.pdf
...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300 m/s2 ...
https://www.omron-ap.co.th/data_pdf/mnu/zs-hldc__-n_inst-5727458-6b.pdf
...er case, 1000 VAC, 50/60 Hz, 1 min 1500 V peak-to-peak, pulse width 0.1 μs/1 μs, rising edge: 1 ns pulse 10 to 150 Hz, 0.7-mm double amplitude, 80 min each in X, Y, and Z directions 300 m/s2 ...
https://www.omron-ap.co.th/data_pdf/mnu/zs-hldc___inst-7978908-3g.pdf
...he Master Unit does not required communications power. 5 CJ1W-CRM21 External Interface CRM21 MS NS +100 789 23 1 2 3 01 4 NETWORKPS 789 01 X100 23 MODE 789 BS- Display Section Shows the Maste...
https://www.omron-ap.com.my/data_pdf/cat/cj1w-crm21_ds_e_11_10_csm1634.pdf
...dCmd instruction with NJ-series controller) 4 CJ1W-DRM21 External Interface Indicators DRM21 MS NS 789A F 012 3456 D BC E 9 01 78 9 01 23 456 456 23 Unit No. switch This switch sets the unit ...
https://www.omron-ap.com.my/data_pdf/cat/cj1w-drm21_ds_e_8_12_csm1635.pdf
...ting of linked operation between axes. 1 CJ1W-NC@71 System Configuration Programmable Terminals NS-series * * Product no longer available to order. Using the CX-Motion-NCF allows all paramete...
https://www.omron-ap.com.my/data_pdf/cat/cj1w-nc_71_ds_e_9_8_csm1697.pdf
...if you use a reduction gear. 1 CJ1W-NC@@4 System Configuration CJ Series Programmable Terminals NS Series * * Product no longer available to order. XW2Z@@@J-G@ Support Software CX-Programmer ...
https://www.omron-ap.com.my/data_pdf/cat/cj1w-nc__4_ds_e_8_8_csm2080.pdf
...rmat Network communications Record contents Indices (record number), time stamps (hh:mm:ss:ms), ns, sampling indices (serial numbers starting at 0 when sampling is started), data for each sym...
https://www.omron-ap.com.my/data_pdf/cat/cj1w-spu01-v2_ds_e_7_8_csm2167.pdf
...emory and data memory. Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 μs. The more advanced motion control by the lower cost: Synchrono...
https://www.omron-ap.com.my/data_pdf/cat/cj2h-cpu-eip_ds_e_11_4_csm1780.pdf
...emory and data memory. Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0.59 μs. Maximum throughputs with High-speed interrupt function Effici...
https://www.omron-ap.com.my/data_pdf/cat/cj2h-cpu_ds_e_10_3_csm2011.pdf
... to your application needs. • Faster processors; LD instruction execution time is reduced to 40 ns, floating point trigonometrics in less than 1 μs. • Optional Pulse I/O Modules can be mounte...
https://www.omron-ap.com.my/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf
...d circuits) Noise immunity Power supply normal: ±600 V for 10 minutes with a pulse width of 100 ns to 1 µs Power supply common: ±1,500 V for 10 minutes with a pulse width of 100 ns t...