Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 6601 - 6620 of 12242
PDF1 New Product Single-phase Voltage Relay

...d during the instable period when the power is first turned on. There is no relay output during timer operation. Undervoltage Operation Diagram (Output Relay Drive Method: Normally Open) DIP ...

https://www.fa.omron.com.cn/data_pdf/cat/k8ab-vs_ca_e_1_1_csm1994.pdf

PDF1 New Product Single-phase Voltage Relay

...d during the instable period when the power is first turned on. There is no relay output during timer operation. Overvoltage and Overvoltage Operation Diagram (Overvoltage Pre-alarm Mode) DIP...

https://www.fa.omron.com.cn/data_pdf/cat/k8ab-vw_ca_e_1_1_csm1995.pdf

PDFCSM_K8AB_series_Outline_DS_E_3_3

...m indicator Lit Lit Flashing Flashing T: Operation time (0.1 to 30 s) T1: 1 s or 5 s selection (Timer when the control power supply is turned ON.) Communications bases must be carefully monit...

https://www.fa.omron.com.cn/data_pdf/cat/k8ab_series_outline_ds_e_3_3_csm378.pdf

PDF1 Digital Heater Element Burnout Detector

...ircuit detection, SSR open circuit detection, voltage fluctuation compensation, output ON-delay timer, energy-saving mode, key protection, and power supply voltage measurement Ambient tempera...

https://www.fa.omron.com.cn/data_pdf/cat/k8ac-h_n137-e1_10_1_csm1991.pdf

PDF1 Single-phase Current Relay K8AK-AS

... setting range (LOCK) Note: Enabled only for overcurrent operation. 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-as_n179-e1_4_7_csm1020909.pdf

PDF1 Single-phase Overcurrent/Undercurrent Relay

... setting range (LOCK) Note: Enabled only for overcurrent operation. 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-aw_n180-e1_4_8_csm1020910.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...

...d during the instable period when the power is first turned on. There is no relay output during timer operation. 3. Phase loss is detected by L1, L2, and L3 voltage drops. A phase loss will e...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...

...d during the instable period when the power is first turned on. There is no relay output during timer operation. 3. Phase loss is detected by L1, L2, and L3 voltage drops. A phase loss will e...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf

PDF1 Three-phase Voltage Relay K8AK-PW

...d during the unstable period when the power is first turned ON. There is no relay output during timer operation. 3. L1 and L2 use the same power supply and will not operate due to an undervol...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf

PDF1 Single-phase Voltage Relay K8AK-VS

...d during the instable period when the power is first turned on. There is no relay output during timer operation. Undervoltage Operation Diagram (Output Relay Drive Method: Normally Open) DIP...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-vs_n181-e1_2_9_csm1020911.pdf

PDF1 Single-phase Overvoltage/Undervoltage Relay

...d during the instable period when the power is first turned on. There is no relay output during timer operation. Overvoltage and Overvoltage Operation Diagram (Overvoltage Pre-alarm Mode) DI...

https://www.fa.omron.com.cn/data_pdf/cat/k8ak-vw_n182-e1_2_8_csm1020912.pdf

PDF1 Three-phase Asymmetry and Phase-sequence Phase-l...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8ds-pa_n193-e1_2_5_csm1020923.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8ds-pm_n192-e1_2_5_csm1020922.pdf

PDF1 Three-phase Undervoltage and Phase-sequence Phas...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8ds-pu_n191-e1_2_6_csm1020921.pdf

PDF1 Three-phase Voltage, Asymmetry, and Phase-sequen...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8ds-pz_n194-e1_2_6_csm1020924.pdf

PDF1 Single-phase Current Relay K8DT-AS

...etting range (T) 0.1 to 30 s Startup lock time setting range (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.com.cn/data_pdf/cat/k8dt-as_n201-e1_1_9_csm1050137.pdf

PDF1 Single-phase Overcurrent/Undercurrent Relay

...etting range (T) 0.1 to 30 s Startup lock time setting range (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enab...

https://www.fa.omron.com.cn/data_pdf/cat/k8dt-aw_n202-e1_2_2_csm1050138.pdf

PDF1 New Product Conductive Level Controller

...t Conductive Level Controller K8DT-LS Ideal for water level control. Sensitivity adjustment and timer for easy usage. •Sensitivity adjustment from 10 k to 100 kΩ. •Enables easy onsite adjustm...

https://www.fa.omron.com.cn/data_pdf/cat/k8dt-ls_n205-e1_1_8_csm1050141.pdf

PDF1 Three-phase Voltage and Phase-sequence Phase-los...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8dt-pm_n207-e1_1_9_csm1050143.pdf

PDF1 Three-phase Voltage, Asymmetry, and Phase-sequen...

...during the unstable period when the power is first turned ON. There is no contact output during timer operation. 3. Phase loss is detected by a drop in the L1, L2, or L3 voltage. A phase loss...

https://www.fa.omron.com.cn/data_pdf/cat/k8dt-pz_n208-e1_1_9_csm1050144.pdf

Results 6601 - 6620 of 12242

Select Country in