Site Search | Product Search | IA Global Search |
...munication port 1 Communications port 1 (RS-232C) S To connect to communication port 2 I/O port selector switch RS-232C This is a 9-pin RS-232C/RS-422A connector. Use a connector cab...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v022-04_nt600s-st121(b)-ev_.pdf
...25-pin connector at one end and a 9 pin connector at the other end. Set the communications path selector to the RS-232C side (upper side) before using this port. I/O port selector...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v026-01_nt600m-lk201_202.pdf
... (SW4) Set this switch to “2”. ⋅ Communications speed (SW3) Set this switch to “4” to select 4800 bps. Set this switch to “5” to select 9600 bps. Set this switch to...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v054-01_nth25_nth25c.pdf
... to 2. • Communications speed (SW3) Set this switch to 5 to select 9600 bps. Set this switch to 6 to select 19200 bps. Setting the Rear Switches • 1-to-1/1-to-N selection (DIP ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v062-e1-06_nt31_31c_setup.pdf
.... Set this switch to 6 to select 19200 bps. 50 Section 4-1 Connecting to the RS-232C Port at the Host Setting the Rear Switches • 1-to-1/1-to-N selection (DIP switch) Set #3 to ON. O...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v063-e1-05_nt631_631c_setup.pdf
... reset KM1 Advantages • Reset mode can be selected individually. • Operation of each switch can be monitored. Disadvantages • There are many Safety Relay Units used. KM2 M KM2 Reset SW KM1 Do...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v090-e1-11_nsh5-sq_10b-v2.pdf
... Command level, parity, and transfer code (SW4) Set this switch to 2. SW4 • Baud rate (SW3) Set this switch to 5 to select 9,600 bps. Set this switch to 6 to select 19,200 b...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v091-e1-01_nt20.pdf
... this switch to 2. • Communications speed (SW3) Set this switch to 5 to select 9600 bps. Set this switch to 6 to select 19200 bps. Setting the Rear Switches • 1-to-1/1-to-N ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v098-e1-05_ns15_12_10_8_5.pdf
... Gray/ Write data input bit 7 ID7 Black Verification data input bit 7 (VERIFY) Gray/ Read/Write selector input R/W White Not used Not used Not used Shielded FG Note1: In the table, (AUTO), (S...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v600-ham81_inst-1123482-2e.pdf
...e data input bit 7 21 ID7 Black Verification data input bit 7 (VERIFY) 22 Gray/White Read/Write selector input R/W Not used 23 − − Not used 24 − − Not used 25 − − Shielded 26 − FG Note 1 : In...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v600-ham91_inst-1124676-6e.pdf
...t : Lower digit (right digit) setting Example : When setting the address to 002AH, set the left selector to 2 and the right selector to A. Access mode switch Used to select ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/v600-har92_inst-1122965-9e.pdf
... power is supplied to Power Supply Power fuse 2 A 250 V (5.2-dia. x 20) MF51NR AC Input Voltage selector terminals Short: 100 to 120 VAC Open: 200 to 240 VAC LG Terminals for external connect...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w111-10_c200h-cpu01-e_03-e_11-e.pdf
... switch, causing PC operation to begin if the mode is set to RUN or MONITOR. The mode can be changed to RUN or MONITOR with the mode switch after entering the password. ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w130-e1-05_c200h-cpu01-e_03-e_11-e.pdf
...use (3 A, 250 V, 6.35-dia. x32) POWER indicator Lights when power is supplied. AC input Voltage selector Short: 100 to 120 V Open: 200 to 240 V LG Terminals for external connections GR + + 0....
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w132-04_c500.pdf
... in the Subsystem increases, the number of LR bits assigned to each PC Link Unit must decrease. Switch 5: Transmission Line Selector Set switch 5 to the right if only wire c...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w135-03_c200h-lk401_c500-lk009-v1.pdf
...use (3 A, 250 V, 6.35-dia. x32) POWER indicator Lights when power is supplied. AC input Voltage selector Short: 100 to 120 V Open: 200 to 240 V Ground this terminal at a resistance of less th...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w139-e1-04_c1000h_c2000h.pdf
... switch, causing PC operation to begin if the mode is set to RUN or MONITOR. The mode can be changed to RUN or MONITOR with the mode switch after entering the password. ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w140-04_c1000h_c2000h.pdf
...x1 SW3 Baud rate SW4 Command level, parity, and transmission code DIP switch 1 and 2 not used. 3: Link type (see p 27) 4: 5-V power supply (see later) RS-232C cable connector 24 CTS ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w143-07_c200h-lk_c500-lk_3g2a6-lk.pdf
...ergency stop pushbutton (PB2): 00005 Manual bin-return pushbutton (PB3): 00006 Manual/automatic selector for bin return (CS): 00007 The GJ instruction is used to jump to the group program. Th...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w149-02_c1000hf.pdf
...Nomenclature and Functions Switches, Controls, and Jacks Switches and controls MACHINE No. Mode Selector Function Sets the Voice Unit system configuration unit number to any integer between 0...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w172-02_c200h-ov001.pdf