Site Search | Product Search | IA Global Search |
...CSM_G3NA_DS_C_12_19 400-820-4535 www.fa.omron.com.cn咨询电话最新信息电话1 固态继电器G3NA 适用负载5~90A、种类丰富的通用型固态继电器 •尺寸小巧,且全系列产品拥有相同的安装尺寸,便于内...
https://www.fa.omron.com.cn/data_pdf/cat/g3na_ds_c_12_19.pdf
...1 Solid State Relays G3NA The reliable choice for Hockey-puck-style Solid State Relays. Available in a Wide Range of Currents. •All models feature the same compact dimensions to provide a uni...
https://www.fa.omron.com.cn/data_pdf/cat/g3na_j166-e1_2_8_csm1057968.pdf
...24V AC24~220V下75A(40℃时)G3NB-275B-1 DC5~24V AC24~220V下90A(40℃时)G3NB-290B-1 DC5~24V 型号 R99-12 FOR G3NA 型号 R99-11 型号可用的SSR Y92B-N50 G3NB-205B-1 G3NB-210B-1 Y92B-N100 G3NB-22...
https://www.fa.omron.com.cn/data_pdf/cat/g3nb-1_j164-cn5_4_2.pdf
...3NB-275B-1 5 to 24 VDC 90 A at 24 to 220 VAC (at 40°C) G3NB-290B-1 5 to 24 VDC Model R99-12 FOR G3NA Model Applicable SSR Y92B-N50 G3NB-205B-1 G3NB-210B-1 Y92B-N100 G3NB-220B-1 Y92B-N150 G3NB...
https://www.fa.omron.com.cn/data_pdf/cat/g3nb-1_j164-e1_4_3_csm1013815.pdf
...傀扵颂 G3NB塟香颂苝轰嘚乐癌DC5-24V蔼蛟鋂菍晖煜践郝穿塟敦龄嘚乐。 咕对赤缼刀竞枫尽 150A 90A 75A 60A 45A 15A 5A G3NB灿 G3NA剥G3NB竞褒催藐尽灿接繠剑疯棺程刀 E5CSL/E5CWL 悼晇来茎刀 G3NB 剑疯棺程...
https://www.fa.omron.com.cn/data_pdf/cat/g3nb_j192-cn5_2_1.pdf
...20A AC100~240V DC5V G3NE-220TL-US DC5 DC12V G3NE-220TL-US DC12 DC24V G3NE-220TL-US DC24 适用SSR型号 G3NA、G3NE用R99-12 FOR G3NA 适用SSR型号 G3NA-205B-UTU、 G3NA-21...
...E-220TL-2-US DC12 24VDC G3NE-220TL-US DC24 G3NE-220TL-2-US DC24 Model Applicable SSR R99-12 FOR G3NA G3NE Model Applicable SSR Y92B-N50 G3NE-205T(L)(-2)-US/-210T(L)(-2)-US Y92B-N100 G3NE-220T...
https://www.fa.omron.com.cn/data_pdf/cat/g3ne_ds_e_5_1_csm166.pdf
...启动和控制使用 EST2-2C-MV3 CX-Thermo支持软件的系统。 •使用EST2-2C-MV3 CX-Thermo支持软件可以通过电脑设定EJ1的参数。 EJ1 TC2 EDU G3NA ᗕ㒻⬉఼ E58-CIFQ1 ⏽ᑺ Ӵᛳ఼ ࡴ⛁఼ ᇣൟ⬉ᄤ⚸ㆅ 䅵ㅫᴎ ষA䖲఼ 35 控制...
https://www.fa.omron.com.cn/data_pdf/mnu/ej1_operation_manual.pdf
...推奨ヒューズ容量適合SSRヒューズ(IEC60269-4) G3NA定格出力電流下記用途に使用される場合、当社営業担当者までご相談のうえ仕様書などによりご確認いただくとともに、定格・性能に対し余裕を持った使い方...
https://www.fa.omron.com.cn/data_pdf/mnu/g3na_inst-9447124-3a.pdf
...设定工具对小型电炉进行设定、控制时的构成示例和步骤如下所示。 EJ1 TC2 EDU 1 2 24-240VAC~ 40A LOAD INPUT 3 + - 4 5 24VDC- G3NA-240B G3NA 固态继电器 E58-CIFQ1 温度传感器加热器小型电炉 P...
...は、0.78~0.98N・mにて締めつけてください。 ・次の機種をご使用の際は、放熱器の金属部をアースに接続してください。 (G3NA-D210B、G3NA-4□□B) ●放熱器の盤への取りつけについて・DINレール取り...
https://www.fa.omron.com.cn/data_pdf/mnu/y92b-p250nf_inst-0631650-0b.pdf
...drive SSRs) for the Temperature Controller is 21 mA. (B): The input impedance for SSRs is 7 mA (G3NA). In this case, the number of SSRs that can be connected in parallel is (A) ÷ (B), therefo...
https://www.omron-ap.co.in/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf
...drive SSRs) for the Temperature Controller is 21 mA. (B): The input impedance for SSRs is 7 mA (G3NA). In this case, the number of SSRs that can be connected in parallel is (A) y (B), therefo...
https://www.omron-ap.co.in/data_pdf/cat/ej1_h236-e1_4_1_csm1121137.pdf
...Solid State Relays G3NA The reliable choice for Hockey-puck-style Solid State Relays. Available in a Wide Range of Currents. • All models feature the same compact dimensions to provide a unif...
https://www.omron-ap.co.in/data_pdf/cat/g3na_j166-e1_2_8_csm1057968.pdf
...in Engineering Data. Accessories (Order Separately) One-touch Mounting Plates Model R99-12 FOR G3NA Heat Sinks Slim Models Enabling DIN-track Mounting Model Y92B-N50 Applicable SSR G3NB-205B...
https://www.omron-ap.co.in/data_pdf/cat/g3nb-1_j164-e1_4_3_csm1013815.pdf
...to the model number. Accessories (Order Separately) One-touch Mounting Plates Model R99-12 FOR G3NA Applicable SSR G3NE Heat Sinks The following heat sinks are thin and can be DIN-track moun...
https://www.omron-ap.co.in/data_pdf/cat/g3ne_ds_e_5_1_csm166.pdf
...SSRの取り付け間隔 (盤内取り付け条件) > 形 G3NA ソリッドステート・リレー 取扱説明書 オムロン製品をお買いあげいただきありがとうございます。 この製品を安全に正しく使用していただくために、 お...
https://www.omron-ap.co.in/data_pdf/mnu/g3na_inst-9447124-3a.pdf
...は、0.78∼0.98N・mにて締めつけてください。 ・ 次の機種をご使用の際は、放熱器の金属部をアースに接続してください。 (G3NA-D210B、G3NA-4□□B) ● 放熱器の盤への取りつけについて・DINレール取り...
https://www.omron-ap.co.in/data_pdf/mnu/y92b-p250nf_inst-0631650-0b.pdf
...drive SSRs) for the Temperature Controller is 21 mA. (B): The input impedance for SSRs is 7 mA (G3NA). In this case, the number of SSRs that can be connected in parallel is (A) ÷ (B), therefo...
https://www.omron-ap.co.nz/data_pdf/cat/ej1_ds_e_12_5_csm222.pdf
...drive SSRs) for the Temperature Controller is 21 mA. (B): The input impedance for SSRs is 7 mA (G3NA). In this case, the number of SSRs that can be connected in parallel is (A) y (B), therefo...
https://www.omron-ap.co.nz/data_pdf/cat/ej1_h236-e1_4_1_csm1121137.pdf