Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 7201 - 7220 of 41694
E2ER-X10D1 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55498/

E2ER-X3D1 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55499/

E2ER-X7D1 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55500/

E2ER-X10D2 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55504/

E2ER-X2D2 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55505/

E2ER-X3D2 5M | OMRON Industrial Automation

...d the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 1,000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/55506/

G2R-1-SD DC100 | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5667/

G2R-1-SD DC24 | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5669/

G2R-1-SD DC5 | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5670/

G2R-1-SND DC12 | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5680/

G2R-1-SND DC24 | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5681/

G2R-1-SNDI DC24 (S) | OMRON Industrial Automation

... Diode Contact form SPDT Contact method Single Contact material Ag alloy Contact rated load 250 VAC 10 A (Resistive load) 250 VAC 7.5 A (Inductive load (cosφ = 0.4)) 30 VDC 10 A (Res...

https://www.ia.omron.com/product/item/5683/

E3JK-DN11 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1500 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/58/

E3JK-DN12 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1500 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/59/

E3ZM-B61T 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/594/

E3ZM-B61T-C 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/595/

E3ZM-B66T | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/598/

E3ZM-B66T-C | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/599/

E3JK-DP11 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1500 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/60/

E3ZM-B81T 2M | OMRON Industrial Automation

...ith no condensation) Insulation resistance 20 MΩ min. (500 VDC megger) Dielectric strength 1000 VAC 50/60 Hz 1 min Vibration resistance Destruction: 10 to 55 Hz, 1.5 mm double amplitude each ...

https://www.ia.omron.com/product/item/604/

Results 7201 - 7220 of 41694