| Site Search | Product Search | IA Global Search |
...tions / 1 minute Mechanical: 30 operations / 1 minute Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 2500 VAC 50/60 Hz 1 min ...
...tions / 1 minute Mechanical: 30 operations / 1 minute Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength Between each terminal of the same polarities: 2500 VAC 50/60 Hz 1 min ...
...ackground: 120 mm min.: 15 to 50 mm Light source Red LED (660 nm) Power supply voltage 12 to 24 VDC±10% ripple (p-p) 10% max. Current consumption 25 mA max. Control output NPN open collector ...
...sition of NC contact closing Left side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NC+SPST-NO Rated through current 10 A Ratings (AC) Resisti...
...sition of NC contact closing Left side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NO+SPST-NC Rated through current 10 A Ratings (AC) Resisti...
...ition of NC contact closing Right side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NC+SPST-NO Rated through current 10 A Ratings (AC) Resisti...
...sition of NC contact closing Left side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form SPST-NO/SPST-NC Rated through current 10 A Ratings (AC) Resisti...
...sition of NC contact closing Left side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NC+SPST-NO Rated through current 10 A Ratings (AC) Resisti...
...sition of NC contact closing Left side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NO+SPST-NC Rated through current 10 A Ratings (AC) Resisti...
...ition of NC contact closing Right side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NC+SPST-NO Rated through current 10 A Ratings (AC) Resisti...
...ition of NC contact closing Right side Load For General load Minimum applicable load 10 mA at 5 VDC Contact rating Contact form DPST-NO+SPST-NC Rated through current 10 A Ratings (AC) Resisti...
...ject Iron 54 x 54 x 1 mm Response frequency 30 Hz (Average value) Power supply voltage 12 to 24 VDC ripple (p-p) 10% max. Operating voltage range 10 to 30 VDC Leakage current 0.8 mA ...
...ded metal 50 x 50 x 1 mm Response frequency 70 Hz (Average value) Power supply voltage 12 to 24 VDC ripple (p-p) 10% max. Operating voltage range 10 to 30 VDC Current consumption at ...
...ject With grounded metal 50 x 50 x 1 mm Response frequency 100 Hz Power supply voltage 12 to 24 VDC ripple (p-p) 10% max. Operating voltage range 10 to 30 VDC Current consumption at ...
...ject With grounded metal 50 x 50 x 1 mm Response frequency 100 Hz Power supply voltage 12 to 24 VDC ripple (p-p) 10% max. Operating voltage range 10 to 30 VDC Current consumption at ...
...3 to 3 mm Repetition precision ±0.2 mm max. Sensing object Liquid Power supply voltage 12 to 24 VDC ripple (p-p) 10% max. Operating voltage range 10.8 to 30 VDC Current consumption 1...
...nob type Color of operating portion Black Reset method Manual Minimum applicable load 1 mA at 5 VDC Contact rating Contact form SPDT Ratings (DC) Resistive load: 0.1 A at 30 VDC Rati...
...r of operating portion White Transparency/Opacity Transparent Minimum applicable load 1 mA at 5 VDC Contact rating Contact form SPDT Ratings (DC) Resistive load: 0.1 A at 30 VDC Rati...
... voltage ±10% range Insulation resistance Between charged parts and the case: 50 MΩ min. at 500 VDC Dielectric strength Between charged parts and the case: 2,000 VAC 50/60 Hz 1 min Vibration ...
...ject With grounded metal 50 x 50 x 1 mm Response frequency 100 Hz Power supply voltage 12 to 24 VDC Operating voltage range 10 to 30 VDC Current consumption 15 mA max. Control output...