| Site Search | Product Search | IA Global Search |
...m hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/clamp switch, (A-B) calculations *3, thickness calculatio...
https://www.omron-ap.co.nz/data_pdf/cat/zx2_ds_e_6_7_csm2680.pdf
...m hold, peak-to-peak hold, self-peak hold, self-bottom hold, average hold, zero reset, On-delay timer, OFF-delay timer, keep/clamp switch, (A-B)calculations *3, thickness calculation...
https://www.omron-ap.co.nz/data_pdf/cat/zx2_e406-e1_15_1_csm2639.pdf
...rameters Service Unit Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note:...
https://www.omron-ap.co.nz/data_pdf/mnu/84-000830-f_qx-830.pdf
...rameters Service Unit Allows the user to set up the output to toggle to active when the service timer has expired. This condition will only be held for one service timer click. Note:...
https://www.omron-ap.co.nz/data_pdf/mnu/84-000870-g_qx-870.pdf
...s in the power supply • If the connected power supply is faulty • If a CPU Unit error (watchdog timer error) or CPU Unit reset occurs • If a major fault level Controller error occurs • While ...
https://www.omron-ap.co.nz/data_pdf/mnu/ck3eseries(safetyprecautions)_inst-3102733-5d.pdf
...s in the power supply • If the connected power supply is faulty • If a CPU Unit error (watchdog timer error) or CPU Unit reset occurs • If a major fault level Controller error occurs • While ...
https://www.omron-ap.co.nz/data_pdf/mnu/ck3m_ck5mseries(safetyprecautions)_inst-2824255-1f.pdf
...torque. 10% or more of the stable sensing distance Teaching or manual adjustment Fun- OFF-delay timer ctions Zero reset / E2CY-SD41 12 to 24 VDC±10%, ripple (p-p): 10% max. 1,080 mW max. (45 ...
https://www.omron-ap.co.nz/data_pdf/mnu/e2cy_inst-2159957-8c.pdf
... using the product as a general sensor, it operates in the standard I/O mode (SIO mode). *3 The timer function of the control output can be set up by the IOLink communications. ( It is able t...
https://www.omron-ap.co.nz/data_pdf/mnu/e2ew-(q)xb_xc_inst-4606998-0h.pdf
...R/W 1byte 0x04 66 2 制御出力2タイマ時間設定 ○ UInteger R/W 2byte ― 160 0 稼働時間 ― UInteger R 3byte ― Timer Output 1 (Mode) 控制输出1定时模式切 Timer Output 1 (Time) 控制输出1定时...
https://www.omron-ap.co.nz/data_pdf/mnu/e2ew-(q)xbseries(indexlist)_inst-4607302-3d.pdf
...R/W 1byte 0x00 66 2 制御出力2タイマ時間設定 ○ UInteger R/W 2byte ― 160 0 稼働時間 ― UInteger R 3byte ― Timer Output 1 (Mode) 控制输出1定时模式切 Timer Output 1 (Time) 控制输出1定时...
https://www.omron-ap.co.nz/data_pdf/mnu/e2ew-xb-evseries(indexlist)_inst-3644179-2a.pdf
... using the product as a general sensor, it operates in the standard I/O mode (SIO mode). *3 The timer function of the control output can be set up by the IOLink communications. ( It is able t...
https://www.omron-ap.co.nz/data_pdf/mnu/e2ew-xb_xc-ev_inst-3644177-6a.pdf
... input *1 Power supply voltage Control output hs 3750 MODE button, Use UP/DOWN %n-d (b)On-delay Timer On-delay Timer Delays the output ON after detection. Incident Light No Incident ...
https://www.omron-ap.co.nz/data_pdf/mnu/e2nc-ea__series_inst-3128438-9c.pdf
...are made in RUN and T mode based on the display values and the threshold, hysteresis width, and timer settings. The judgement output is held while judgement output hold input is ON. Measureme...
...t Hysteresis Value ⃝ UInteger R/W 2byte 0x002B 0x0057 UInteger W 1byte ー 制御出力1 タイマモード切替 Output1 Timer (Mode) 制御出力1 タイマ時間設定 Output1 Timer (Time) ⃝ UInteger R...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-f1000i___1500i__series_indexlist_inst-2873829-8f.pdf
.../W 4byte 10 0 to 1000 Access Length Default value Vendor Command - Uinteger W 1byte - 1 Output1 Timer (Mode) ○ Uinteger R/W 1byte 0x00 2 Output1 Timer (Time) ○ Uinteger R/W 2byte 5 1...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-hf6000_m__(indexlist)_inst-3644117-2a.pdf
...ect Teach Select 6-2 (page 10) Output 1 Mode 3-3 (page 3) Output 1 Logic 6-4 (page 10) Output 1 Timer Mode 6-5 (page 10) Output 1 Timer Time Teach 3sec. Object Out1 Mode Single Out1 ...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-hf6000_m_inst-3669664-2c.pdf
...ACH 50 ms UP DOWN 3-4(page4) Single Output 1 Logic Out1 Logic UP DOWN 6-2(page10) N.O. Output 1 Timer Mode1 UP Timer Mode DOWN 6-3(page10) Off Output 1 Timer Time1 UP ...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-hl150__hl500__inst-5630539-9e.pdf
...Record - Uinteger R Vendor Command - Backup target Format Access Length Default value 1 Output1 Timer (Mode) ○ Uinteger R/W 1byte 0x00 2 Output1 Timer (Time) ○ Uinteger R/W 2byte 5 1...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-hl150_m___500_m___indexlist_inst-5603669-0b.pdf
...⃝ ー UInteger UInteger UInteger R/W R/W W 1byte 2byte 1byte 0x01 0x0000 ー 制御出力1 タイマモード切替 Output1 Timer (Mode) ⃝ UInteger R/W 1byte 0x00 *1 OMRON Corporation 19 32byte All *** 未...
https://www.omron-ap.co.nz/data_pdf/mnu/e3as-l80m___200m__series(indexlist)_inst-2872801-2e.pdf
...OWN MODE UP/DOWN (1 to 9999ms in 1ms steps; the initial value: 10ms) Time Off %n-d (a)Off-delay Timer Off-delay Timer Holds the output ON for (a) detection by PLC when the detection ...
https://www.omron-ap.co.nz/data_pdf/mnu/e3c-lda__nseries_inst-5710590-3a.pdf