| Site Search | Product Search | IA Global Search |
...nection method Model 12 to 24 VDC Open-collector output (NPN) Gray 256, 360, (720) *2 Pre-wired Connector Model (1 m) E6C3-AG5C-C (resolution) 1M Example: E6C3-AG5C-C 256P/R 1M 256, 360, 720,...
https://www.omron-ap.com.my/products/family/1347/lineup.html
... directions Degree of protection IEC 60529 IP65, in-house standards: oilproof Connection method Connector Models *6 Pre-wired Models (Standard cable length: 1 m) Material Case: Aluminum, Main...
https://www.omron-ap.com.my/products/family/1347/specification.html
...er supply voltage Rated I/O power supply voltage Model Input NPN (+ common) 8 points Sensor I/O connector Supplied from the communications connector Supplied from the communications ...
https://www.omron-ap.com.my/products/family/1354/lineup.html
...T2-OD08C(-1) Communications power supply voltage 11 to 25 VDC (Supplied from the communications connector) I/O power supply voltage 20.4 to 26.4 VDC (24 VDC -15%/+10%) Noise immunity Conforms...
https://www.omron-ap.com.my/products/family/1354/specification.html
...mes each in 6 directions (up/down, left/right, and forward/backward) Connection method Prewired connector (2 m from the Sensor Head to the Preamplifier, 0.2 m from the Preamplifier to th...
https://www.omron-ap.com.my/products/family/1424/specification.html
...og / Manual / CAD / Software last update: November 16, 2012 Model Specifications CS1W-CIF31 USB Connector to D-sub Connector Conversion Cable.0.5m.Attached drivers (On CD-ROM) last u...
https://www.omron-ap.com.my/products/family/1426/lineup.html
...eral Specifications USB interface rating Conforms to USB Specification 2.0 DTE speed 115.2 kbps Connector specifications Computer end USB (type A plug, male) PLC end or PT end RS-232C (D-sub ...
https://www.omron-ap.com.my/products/family/1426/specification.html
...5EN-H/E5CN-H/E5GN USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Connector specifications Computer: USB (type A plug) Temperature Controller: Setup Tool port (o...
https://www.omron-ap.com.my/products/family/1434/specification.html
... supply voltage Model Relay output 16 points M3 terminal block Supplied from the communications connector Supplied from communications connector DRT2-ROS16 Expansion Units One Expans...
https://www.omron-ap.com.my/products/family/1440/lineup.html
...l Specifications Communications power supply voltage 11 to 25 VDC (Supplied from communications connector) Communications power supply current consumption 215 mA max. (24 VDC), 395 mA max. (1...
https://www.omron-ap.com.my/products/family/1440/specification.html
...le Data links and message service • CD-ROM ×1 * • INSTALLATION GUIDE (W467) ×1 • Communications connector ×1 3G8F7-CLK23-E CE, KC * The CD-ROM contains the following software. • Controller ...
https://www.omron-ap.com.my/products/family/1452/lineup.html
...nnection method PLC: Connection to terminal block Computer: Connection using special (supplied) connector Maximum number of nodes 32 or 62 nodes *2 *3 Applicable Programming Devices CX-Integr...
https://www.omron-ap.com.my/products/family/1452/specification.html
...e of protection (Sensor Head) IEC60529, IP65 IEC60529, IP67 IEC60529, IP60 *6 Connection method Connector relay (standard cable length: 2 m) Weight (packed state) Approx. 120 g Approx. 140 g ...
https://www.omron-ap.com.my/products/family/1457/specification.html
...ltage Model Inputs NPN (+ common) 16 points M3 Screw terminals Supplied from the communications connector 24 VDC DRT2-ID16 PNP (- common) DRT2-ID16-1 Outputs NPN (- common) DRT2-OD16 PNP (+ c...
...y voltage 11 to 25 VDC Unit power supply voltage Not required (Supplied from the communications connector.) I/O power supply voltage 20.4 to 26.4 VDC (24 VDC -15%/+10%) Communications power s...
https://www.omron-ap.com.my/products/family/146/specification.html
...[]F D4NS-2[]F D4NS-4[]F D4NS-2[]F-SJ D4NS-4[]F-SJ 2-Conduit Types D4NS-6[]F D4NS-8[]F 1-Conduit Connector Types D4NS-9[]F Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies t...
https://www.omron-ap.com.my/products/family/1465/dimension.html
...dering any models that are not listed in this table. Type Contact configuration Conduit outlet/ Connector Model 1-Conduit type Slow-action 1NC/1NO Pg13.5 D4NS-1AF * G1/2 D4NS-2AF * M20 D4NS-4...
https://www.omron-ap.com.my/products/family/1465/lineup.html
...atalog / Manual / CAD / Software last update: July 1, 2016 (Unit: mm) Buffer Block and Bus Line Connector Buffer Block S8T-DCBU-02 Bus Line Connector S8T-BUS03 DIN Rails (Order Separ...
https://www.omron-ap.com.my/products/family/1466/dimension.html
...Model number 24 VDC (24 to 28 VDC) 22.5 V 2.5 A S8T-DCBU-02 Options (Order Separately) Bus Line Connector (Connects to Buffer Block) Type Number of Connectors Model number Connector ...
https://www.omron-ap.com.my/products/family/1466/lineup.html
...400-M1-N 400 to 6,000 mm E4PA-LS600-M1-N Accessories (Order Separately) Sensor I/O Connectors A Connector is not provided with the Sensor. Be sure to order a Connector separately. Ca...
https://www.omron-ap.com.my/products/family/1467/lineup.html