| Site Search | Product Search | IA Global Search |
...to be compatible with the output specifications of the Output Terminal (pull-up resistance: 4.3 kΩ; residual voltage: 1.2 V). Normal Loads A0 A1 Logic Circuits A2 – – – OUT + – + B0 B1 B2 Loa...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w120-e1-08_c500-rm_rt.pdf
...er (0 V) CW pulse or nondirectional pulse output 4 CW pulse or nondirectional pulse output (1.6 kΩ) CW pulse or direction signal output 3 CCW pulse or direction signal output (1.6 kΩ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w137-e1-04_c200h_nc111.pdf
...--------------- ■ TABL】EOFCONTENTS S】ECTIONl PartsCheckandGeneralPrecautions_.__._.。 1⇔1PartsCh㏄k 1-2Restrictions 1-3Precautions S】ECTION2 GeneralDescription..。 。 .。 。 .。 .。 。 。 ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w158-e1-05_s3200-nsb11-e.pdf
...y, 24 VDC 23 Output power supply, 0 V 1.6k Ω (1/2W) 2 (X)/24(Y) CW pulse/pulse output (with 1.6 kΩ resistance) 3 (X)/25(Y) CW pulse/pulse output 1.6 kΩ (1/2W) 13 (X)/15(Y) CCW pulse/...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w166-e1-03_c200h_nc211.pdf
...[W178-E1-01A] S3200 SYSMAC NET System Manual Ca 欝欝馨難繰締智一 ∴・・ 1 、' / ∼ ・ /∴∴:/ ㌘r「 《「1 /、 k/・")・・' }1「∵∴∵㌧ '/ノ// ・〆/ 〉 ・ ・「… }「1 ∼/ / ・ }・・ SYSMAC NET ) SYSTEM...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w178-e1-01a_s3200.pdf
...describesthefunctions,characteristics,andoperatingproceduresoftheHostLinkUnits forusewiththeC20/K-typePCs. Section7describesthebasicphysicalfeaturesoftheHost〕nkUnitsandgivesexamplesofsystems...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w182-e1-01a_3g2c7-lk201-ev1_202-ev1.pdf
... type setting 8 7 9 01 2 3 6 5 4 C200H-TC00@ Setting 0 1 2 3 4 5 6 7 8 9 Sensor type R S K J T E B N L U The switch is factory-set to 2. The selected position is shown by the arrow. Turn the ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w225-e1-05_c200h-tc.pdf
... shown in the following diagram. Input power supply 2-wire method sensor, etc. R = 7.2/(2.4I–3) kΩ max. W = 2.3/R W min. Bleeder resistor SYSMAC R I: Device’s leakage current (mA) R: Bleeder ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w226-e1-07_cqm1.pdf
...-1 Before Operation Input Wiring Diagram Voltage input C200H-AD002 1 MΩ V 0V 1 MΩ COM Shield 10 kΩ 0V Current input 1 MΩ V/I 250 Ω I 0V 1 MΩ COM Shield 10 kΩ FG FG AG 0V V and V/I 0V...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w229-e1-03_c200h-ad002_da002.pdf
...Connect resistors from the shield to the positive and negative terminals. Input device +V R: 15 kΩ + – R 0V +V + – R 0V Shielded twisted-pair cable 12 0 1 2 3 4 5 6 7 8 9 +Voltage input Input...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w258-e1-05_3g2a5-ad_da_c500-ad_da.pdf
...ters. Temperature Sensor Unit Functions Thermocouple input (CPM1A-TS001/002; 2/4 input points): K: –200° to 1,300°C (–300° to 2,300°F) 0.0° to 500.0°C (0.0° to 900.0°F) J: –100° to 850°C (–10...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w317-e1-11_cpm1a.pdf
...veProgramsPropertiesdlalogisdisplayed. tns憾∼u幽stal}・wt噛鴎9杖碗Sta醐コD敏1 1丁口無t威迫酬・口口9槌;pff{加音恥pPP・di§k・ef斑一再]{司.. d轟∨ei≒‖蘇{鹸a糺、 工 一 '1h{"lotiew{ngso∬warecanbeξ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w319-e1-01_ws01-pstf1-e.pdf
...pdialogappears. こぐ り 、ミc=n・``,4;`-II 聡肇饗讐三二ご/治…緬岨・郷「抗=≡ご 三 1'∵' lii蹴ご瑠/ 《 、 電曲1涌uば ぷ錨'脳" 、 、 口a繧k 詣雌必1奮酎Upノ ベシ シ 、 _ 一一 Figure1・3SelectProgr...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w332-e1-01_sysmac-cpt.pdf
...SummaryInformationdialogappears(seeFiguresonpage30). Typethedesiredsummaryinfbrmation. ClickonO〕K. CPTretumsyoutotheprogramintheworkarea. ■TosaveaneXistingproject: ・ClickontheFilemenuandsel...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w333-e1-01_sysmac-cpt.pdf
...Shift]+[T] Force on [PLC] | [Force] | [On] [Ctrl]+[J] Force off [PLC] | [Force] | [Off] [Ctrl]+[K] Cancel force [PLC] | [Force] | [Cancel] [Ctrl]+[L] Begin on-line edit [Programs] | [Online E...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w414-01_ws02-cxpc1-ev3.pdf
...Shift]+[T] Force on [PLC] | [Force] | [On] [Ctrl]+[J] Force off [PLC] | [Force] | [Off] [Ctrl]+[K] Cancel force [PLC] | [Force] | [Cancel] [Ctrl]+[L] Begin on-line edit [Programs] | [Online E...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w425-e1-01_ws02-cxpc1-e-v4.pdf
...s are displayed in step units. 1 step = 4 bytes, so the function block program memory capacity (K bytes) in the CPU Unit's internal flash memory is the value multiplied by 1,024 and divided b...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w437-e1-01_ws02-cxpc1-e-v50.pdf
...ecified word address. Program Instance of Function Block Definition A Input D100 m Input D200 n k Output D300 Examples: If m is type WORD, one word of data from D100 will be passed to the var...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/w438-e1-01_ws02-cxpc1-e-v50.pdf
...D-8FH03PM-E 1-3-1 Sensors and Temperature Ranges Thermocouple models are compatible with either K (CA) or J (IC) sensors and can be set in a temperature range of either 0° to 400°C or 0° to 6...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z042-e1-04_e5zd.pdf
...tions (RESET) Input voltage 24 VDC: +10% (including ripple component), –15% Input impedance 2.2 kΩ Input current 10 mA typ. (24 VDC) On voltage 19 V min. Off voltage 5 V max. Input response t...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z044-e1-04_v600-ca_a-v_.pdf