PDFCaution WARNING Caution NX-series CPU Units

...hat are given in the specifications. z Do not apply voltages that exceed the rated value to any Input Unit. z Do not apply voltages or connect loads to the Output Units or slaves in excess of...

https://www.fa.omron.com.cn/data_pdf/mnu/nxseries-cpu(safetyprecautions)_inst-5725778-9a.pdf

PDFOPERATION MANUAL Cat. No. V236-E1-04

...r confirming that no adverse effects will be caused by extending the cycle time. Otherwise, the input signals may not be readable. !Caution Confirm safety at the destination node before trans...

https://www.fa.omron.com.cn/data_pdf/mnu/v236-e1-04_cs1w-spu0_-v2_cj1w-spu01-v2.pdf

PDFOPERATION MANUAL Cat. No. W345-E1-12

.... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 SECTION 2 CS-series Analog Input Units (CS1W-AD041-V1/081-V1/161) . . . . . . . . . . . . . . . . . . . . 17 2-1 Specifica...

https://www.fa.omron.com.cn/data_pdf/mnu/w345-e1-12_cj1w-ad_da_mad.pdf

PDFPROGRAMMING MANUAL Cat. No. W394-E1-16

...er unit versions Read protection using extended passwords OK (See note.) --- Disabling password input after five consecutive incorrect passwords OK --- Auxiliary Area notification of producti...

https://www.fa.omron.com.cn/data_pdf/mnu/w394-e1-16_cs_cj_nsj.pdf

PDFOMRON Corporation Industrial Automation Company No...

... other models: 6.5 VA max. at 100 to 240 VAC, and 4.1 VA max. at 24 VAC or 2.3 W max. at 24 VDC Input impedance Current input: 150Ωmax., Voltage input: 1 MΩminimum. Current ...

https://www.fa.omron.com.cn/upload/alternative/201504011013421757.pdf

PDFOMRON Corporation Industrial Automation Company

...ed by parameters) (Sale schedule in October 2009) •The model number is changed due to universal input types. The default value of Input Type parameter is modified from platinum resis...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2009076E-2.pdf

PDFOMRON Corporation Industrial Automation Company

...SE CQM1-LSE01 CQM1-LSE02 Recommended Replacement CJ1W-MAD42 CJ1W-MAD42 has no external terminal input. If you need external terminal input, please use CJ1W-INT01 and CJ1M-CPU22/23, a...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2009083E.pdf

PDFOMRON Corporation Industrial Automation Company

...mitter F3W-B[][][]-L Main circuit Picking indicator (red) Brown Pink Blue * Picking instruction input 12 to 24 VDC 0 V Note : The picking indicator will be ON if the terminal is connected to ...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2009126E.pdf

PDFOMRON Corporation Industrial Automation Company

...[][] Wire Connection 14 Product discontinuation S82J series Recommended replacement S8JX series Input Voltage 10W, 25W, 50W, 100W (24V) models 100 to 240 VAC (85 to 264 VAC) (free) 110 to 170...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2010029E.pdf

PDFOMRON Corporation Industrial Automation Company

...8VS series (S8JX-G01515CD for 15V output models) Dimensions and are different. The positions of Input terminals and Output terminals are different. There is a type with large Inrush current. ...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2010031E.pdf

PDFOMRON Corporation Industrial Automation Company

... CRT1B-MD04SLP(-1) CRT1B-ID02JS(-1) CRT1B-ID04JS(-1) CRT1B-OD02JS(-1) CRT1B-MD04JS(-1) Function Input Output I/O Input Output I/O Operation Time Monitor Yes - Contact Operation Monit...

https://www.fa.omron.com.cn/upload/alternative/PRDN-2010201E.pdf

PDFCS/CJ/CP Series with a proven track record

...Analog Output Unit CP1W-TS003/004 CP1W-DA021/DA041/DA042 CJ1W-EIP21 NX-EIC202 CJ1W-ECT21 Analog Input Unit Analog I/O Unit Version Upgraded in December 2014 Released in January 2015 Released ...

https://www.omron-ap.co.in/data_pdf/cat/cs_cj_cp_p097-e1-01.pdf

PDFDigital Temperature Controller

...n on applicable safety standards. Refer to Safety Precautions on 122. Main I/O Functions Sensor Input Universal input • Thermocouple • Pt • Analog current/voltage E5GC Dual displays:...

https://www.omron-ap.co.in/data_pdf/cat/e5_c_e5_c-t_h177-e1_14_15_csm1001508.pdf

PDFMachine Automation Controller NJ-Series

... Built-in EtherNet/IP port EtherCAT Built-in EtherCAT port Slave Terminal 2 Servo Drive/encoder input slaves General-purpose slaves NJ-Series Ordering Information Applicable standards Refer t...

https://www.omron-ap.co.in/data_pdf/cat/nj-series_p140-e1_6_13_csm1067136.pdf

PDFRelay Sockets with Push-In Plus technology

...t 16 I/O points with just one cable with connectors to reduce wiring work. Connector Cable (×1) Input G70V I/O Relay Terminal (One Block, 16 points) PLC (I/O Units) Output G70V I/O Relay Term...

https://www.omron-ap.co.in/data_pdf/cat/pyf-pu_p2rf-pu_g2rv-st_g3rv-st_g70v_p7sa-pu_j213-e1_2_1_csm1050148.pdf

PDFDo not touch the NX bus connector ‫ ە‬Compliance w...

...G 16 AWG 14 Current (MAX) 7A 10A 15A ‫ ە‬Compliance with Class I Division 2 Hazardous Location: Input and output wiring must be in accordance with Class I Div.2 wiring methods and in accordan...

https://www.omron-ap.co.in/data_pdf/mnu/nxseries(precautionsforcompliancewithulstandardandcsastandards)_inst-5365134-2c.pdf

PDFMachine Automation Controller NJ/NX-series

...er program for proper execution before you use it for actual operation. Operation • Specify the input parameter values within the valid range. • In the function or function block with an Enab...

https://www.omron-ap.co.in/data_pdf/mnu/w575-e1-05_sysmac-xr009.pdf

PDFAutomation Software Sysmac Studio

...h encoder channel. Belt Encoder Latch acquires position values of conveyor belt’s encoders when input signal changes its state. You can check the current position and velocity of encoders of ...

https://www.omron-ap.co.in/data_pdf/mnu/w595-e1-11_sysmac-se2___.pdf

PDFAutomation Software Sysmac Studio

... cylinder (Single solenoid type) refers to a component whose piston moves according to a single input value. For the Air cylinder (Single solenoid type) model, set the following parameters. I...

https://www.omron-ap.co.in/data_pdf/mnu/w618-e1-11_sysmacstudio_3dsimulation.pdf

PDFAutomation Software Sysmac Studio

...enever a belt is used in an application. One calibration needs to be performed for each encoder input associated with a robot. 3-3-2 Robot-to-Belt Calibration on page 3-9 Robot-to-Camera Cali...