| Site Search | Product Search | IA Global Search |
...There is no alarm output 2 mode switch. The default setting for alarm output 2 is for the upper limit alarm mode. To change the setting, change the alarm type for alarm output 2 in initial se...
https://www.fa.omron.com.cn/data_pdf/cat/e5cs_ds_e_5_3_csm211.pdf
...s. Input type: 0 K thermocouple−200 to 1300°C Control method:ON/OFF control Alarm type: 2 upper limit Alarm value 1: 20°C (Set the deviation in Set point: 100°C E5ZN unit number: 3 Channel nu...
https://www.fa.omron.com.cn/data_pdf/cat/e5zn_operation_tg_e_2_2_csm251.pdf
...current) for measurements. •Scaling: Convert analog input to a desired value for display (Upper limit setting: -1999.9999 to 9999.9999) •No. of connectable units: Max. 30 * *The maximum numbe...
https://www.fa.omron.com.cn/data_pdf/cat/e9nc-aa_va_e474-e1_2_2_csm1065027.pdf
... 60529) IP65 and IP67 Vibration Resistance (IEC 61496-1) Class 3M4 (IEC TR 60721-4-3) Operation limit: 5 to 150 Hz, Multiple amplitude of 7 mm, Acceleration of 1 G, 10 sweeps each in X, Y, an...
https://www.fa.omron.com.cn/data_pdf/cat/f3sg-r_f094-e1_12_7_csm1040037.pdf
... 2.) S3 E1 Emitter F39-JC@@C-L F39-JC@@C-D Receiver Reset switch (S2) External test switch (S3) Limit switch (S1, S2) OSSD K3 N.C. contact K3 N.O. contact K1, K2 N.O. contact K1, K2 N.C. cont...
https://www.fa.omron.com.cn/data_pdf/cat/f3sn-a_f3sn-b_f3sh-a_ds_csm1257.pdf
...CSM_F92A_DS_E_9_1 1 Inductive Coupler F92A Transmit Limit Switch ON/OFF Signals without Making Contact •By using the magnetic coupling between the F92A and Proximity Sensor coils, the ON/OFF ...
https://www.fa.omron.com.cn/data_pdf/cat/f92a_ds_e_9_1_csm1329.pdf
...and Surge Effects If noise or an electrical surge occurs that exceeds the malfunction withstand limit for the G3PE output circuit, the output will turn ON for a maximum of one half cycle to a...
https://www.fa.omron.com.cn/data_pdf/cat/g3pe_j174-e1_2_1_csm2137.pdf
...d Surge Effects If noise or an electrical surge occurs that exceeds the mal- function withstand limit for the G3PH output circuit, the output will turn ON for a maximum of one half cycle to a...
https://www.fa.omron.com.cn/data_pdf/cat/g3ph_j177-e1-01.pdf
...d Surge Effects If noise or an electrical surge occurs that exceeds the mal- function withstand limit for the G3PH output circuit, the output will turn ON for a maximum of one half cycle to a...
https://www.fa.omron.com.cn/data_pdf/cat/g3ph_j177-e1_2_2_csm1000554.pdf
...同步转矩模式)·Profile position mode (轨迹位置模式) ·Homing mode (原点复位模式)·Touch probe function (锁定功能)·Torque limit function (转矩限制功能) 机型型号单元版本单元Ver.1.0单元Ver.2.0单元V...
https://www.fa.omron.com.cn/data_pdf/cat/g5_series_i819-cn5_1_10.pdf
...er supply. Incorrect wiring may result in burning. •Do not bend the cables beyond their natural limit. Doing so may break the cables. •Do not pull the cables by the power beyond 30 N. Doing s...
https://www.fa.omron.com.cn/data_pdf/cat/g70d-soc08_ds_e_5_1_csm1046356.pdf
... Must Operate time *2 15 ms max. Release time *2 15 ms max. Max. switching frequency Mechanical limit 18,000 operations/h At rated load 1,800 operations/h Insulation resistance 100 MΩ(at 500 ...
https://www.fa.omron.com.cn/data_pdf/cat/g7tc_ds_e_9_1_csm1046354.pdf
...C Transistor (Photocoupler) 24 to 48 VAC (50/60 Hz)/ 12 to 48 VDC 0.05 s to 300 h H3CR-A8S Time-limit contact and instantaneous contact 100 to 240 VAC (50/60 Hz)/ 100 to 125 VDC H3CR-A8E 24 t...
https://www.fa.omron.com.cn/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf
...Conditional short-circuit current 1,000 A Ambient Operating Temperature and Carry Current Upper limit of ambient temperature (°C) Carry current AC/DC (A) Note that the upper limit of...
https://www.fa.omron.com.cn/data_pdf/cat/h5l_ds_e_2_4_csm102.pdf
...liary contact 2PST-2NO) J73KC-AM-40 (Auxiliary contact 4PST-4NO) TH SA G9SA-301 (AC/DC24V) (two limit switch input channels with manual reset) Feedback circuit Feedback loop Recommended repla...
https://www.fa.omron.com.cn/data_pdf/cat/j7kc_j230-e1_9_1_csm1074607.pdf
...) [cycles/hour] 25 Phase failure protection Yes Trip indicator Yes Test trip function Yes Rated limit breaking capacity Icu: Rated limit breaking capacity [kA] (Breaking duty O-CO) I...
https://www.fa.omron.com.cn/data_pdf/cat/j7mc_j233-e1_5_1_csm1074610.pdf
...ip class 10 A 3-pole load operation (At 20°C ambient temperature) IEC 60947-4-1/ JIS C 8201-4-1 Limit operation No operation (cold start) 105% (less than 2 hours) *1 Operation (hot start) 120...
https://www.fa.omron.com.cn/data_pdf/cat/j7tc_j231-e1_7_1_csm1074608.pdf
...er sets the resistance value for detection within the set range. It is factory-set to the upper limit. (Normally, the K7L can be used with the adjuster at this setting.) With any range, resis...
https://www.fa.omron.com.cn/data_pdf/cat/k7l_n211-e1_6_7_csm1050158.pdf
.... The longer the wire length, the larger the measurement error using the KM-NCT-E becomes. •The limit of the wiring length can also be calculated by the following formula. Calculate the wirin...
https://www.fa.omron.com.cn/data_pdf/cat/km-n2_km-n3_n213-e1_3_13_csm1050147.pdf
... usability of your machine by enlarging these objects in size. Dynamically changing upper/lower limit value The upper and lower limit values can be dynamically changed by setting var...
https://www.fa.omron.com.cn/data_pdf/cat/na_v457-e1_3_8_csm1100516.pdf