PDFIncremental 25-mm-dia. Rotary Encoder

...imes each in X, Y, and Z directions Degree of protection*3 IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 500 mm) Material Case: Aluminum alloy, Main unit: Aluminum...

https://www.omron-ap.co.in/data_pdf/cat/e6a2-c_ds_e_8_2_csm490.pdf

PDFIncremental 40-mm-dia. Rotary Encoder

... times each in X, Y, and Z directions Degree of protection IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 500 mm) Materials Case: ABS, Main unit: Aluminum, Shaft: S...

https://www.omron-ap.co.in/data_pdf/cat/e6b2-c_ds_e_6_3_csm491.pdf

PDFSlim Incremental 50-mm-dia. Rotary Encoder

...roved oil-proof construction with sealed bearings) • Side or back connections are possible. Pre-wired Models with cable connected at an angle. For the most recent information on models that h...

https://www.omron-ap.co.in/data_pdf/cat/e6c2-c_ds_e_6_4_csm493.pdf

PDFSlim Encoder with Diameter of 50 mm

...configuration Output code Resolution (pulses/rotation) Connection method 256, 360, (720) *2 Pre-wired Connector Model (1 m) Gray Open-collector output (NPN) 12 to 24 VDC Open-collector output...

https://www.omron-ap.co.in/data_pdf/cat/e6c3-a_ds_e_8_4_csm494.pdf

PDFRugged Incremental 50-mm-dia. Rotary Encoder

...0, 3,600 Connection method Model E6C3-CWZ5GH (resolution) 1M Example: E6C3-CWZ5GH 100P/R 1M Pre-wired (1 m) (See note.) E6C3-CWZ3EH (resolution) 1M Example: E6C3-CWZ3EH 100P/R 1M E6C3-CWZ3XH ...

https://www.omron-ap.co.in/data_pdf/cat/e6c3-c_ds_e_7_3_csm495.pdf

PDFLow-cost Encoder with Diameter of 50 mm

...imes each in X, Y, and Z directions Degree of protection*3 IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 2 m) Material Case: ABS, Main unit: PPS, Shaft: SUS416, Mo...

https://www.omron-ap.co.in/data_pdf/cat/e6cp-a_ds_e_6_5_csm496.pdf

PDFHigh-resolution Encoder with Diameter of 55 mm

...imes each in X, Y, and Z directions Degree of protection*3 IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 0.5 m) Material Case: Zinc alloy, Main unit: Aluminum, Sha...

https://www.omron-ap.co.in/data_pdf/cat/e6d-c_ds_e_5_2_csm497.pdf

PDFAbsolute 60-mm-dia. Rotary Encoder

...collector 256, 360, 720 Gray code PNP open collector 256, 360, 720, 1,024 Connection method Pre-wired Model Pre-wired Connector Model (2 m) Pre-wired Model Pre-...

https://www.omron-ap.co.in/data_pdf/cat/e6f-a_ds_e_7_5_csm498.pdf

PDFIncremental 60-mm-dia. Rotary Encoder

...ections Degree of protection IEC 60529 IP65, in-house standards: oilproof Connection method Pre-wired Models (Standard cable length: 2 m) Material Case: Zinc alloy, Main unit: Aluminum, Shaft...

https://www.omron-ap.co.in/data_pdf/cat/e6f-c_ds_e_6_3_csm499.pdf

PDFHollow-shaft Encoder with Diameter of 40 mm

...ions (excluding shock to the shaft) Degree of protection*3 IEC 60529 IP50 Connection method Pre-wired Models (Standard cable length: 0.5 m) Material Case: Iron, Main unit: Aluminum, Pressboar...

https://www.omron-ap.co.in/data_pdf/cat/e6h-c_ds_e_6_4_csm500.pdf

PDFIoT Status Monitoring Amplifier

... for Sensor Communications Unit 2 outputs E9NC-AA0 Connector for Sensor Communications Unit Pre-wired (2 m) 1 output E9NC-AA10 2M Connector for Sensor Communications Unit 2 outputs E9NC-VA0 C...

https://www.omron-ap.co.in/data_pdf/cat/e9nc-aa_va_e474-e1_2_2_csm1065027.pdf

PDFContact-Type Smart Sensor E9NC-T

...on) Probe Carbide with a round surface, screw thread size: M2.5 Connecting method Materials Pre-wired connector (2 m from the Sensor Head to the Preamplifier) Sensor Head Stainless steel (SUS...

https://www.omron-ap.co.in/data_pdf/cat/e9nc-t_e434-e1_10_4_csm1012458.pdf

PDFPushbutton-type Photomicrosensor

...truction: 500 m/s2 for 3 times each in X, Y, and Z directions Degree of protection IEC IP40 Pre-wired (standard cable Connecting method Pre-wired (robot cable length: 1 m) length: 1 ...

https://www.omron-ap.co.in/data_pdf/cat/ee-sa701_801_ds_e_4_3_csm662.pdf

PDFSlot-type Photomicrosensor with Cable

... for 3 times each in X, Y, and Z directions Degree of protection IEC IP50 Connecting method Pre-wired (standard cable length: 1 m) Weight 18.5 g Material Holder 2 mm EE-SPX305-W2A Response fr...

https://www.omron-ap.co.in/data_pdf/cat/ee-spx-w_ds_e_4_3_csm474.pdf

PDFPipe-mounting Liquid Level Photomicrosensor with B...

... times each in X, Y, and Z directions Degree of protection IEC 60529 IP50 Connecting method Pre-wired (Standard length: 1 m) Weight (packed state) Approx. 55 g Material Accessories Case Cover...

https://www.omron-ap.co.in/data_pdf/cat/ee-spx613_ds_e_5_3_csm477.pdf

PDFWafer-carrier Mounting Photomicrosensors

... for 3 times each in X, Y, and Z directions Degree of protection IEC IP30 Connecting method Pre-wired (Standard length: 2 m) Weight (packaged) Sensor: Approx. 43 g; Accessory (Pedestal): Appr...

https://www.omron-ap.co.in/data_pdf/cat/ee-spy801_802_ds_e_3_3_csm480.pdf

PDFSlot-type Photomicrosensor (Non-modulated) *1

...n on models that have been certified for safety standards, refer to your OMRON website. *1. Pre-wired Models are available only in the EE-SX67 Series. *2. Only for Pre-wired Models. ...

https://www.omron-ap.co.in/data_pdf/cat/ee-sx47_67_ds_e_13_4_csm483.pdf

PDFPhotomicrosensor with Slim Cable (Non-modulated)

...r to your OMRON website. Be sure to read Safety Precautions on page 4. Ordering Information Pre-wired Models Appearance Infrared light Sensing method Cable length Sensing distance Standard Ou...

https://www.omron-ap.co.in/data_pdf/cat/ee-sx77_87_ds_e_7_10_csm484.pdf

PDFUltra-compact Pre-wired Photomicrosensor (Non-modu...

...Ultra-compact Pre-wired Photomicrosensor (Non-modulated) EE-SX95 Meeting Customer Needs with Ultra-compact Sensors that Mount with M3 Screws • Mount using M3 or M2 screws. • Reliable sensing ...

https://www.omron-ap.co.in/data_pdf/cat/ee-sx95_e435-e1_3_6_csm1012815.pdf

PDFSafety Light Curtain/Safety Multi-Light Beam

...SD Manager 3 Mobile APP. *3. Mutual interference can be prevented by Optical Synchronization or Wired Synchronization. *4. Mutual interference can be prevented by Scan Code Selection. *5. In ...

https://www.omron-ap.co.in/data_pdf/cat/f3sg-sr_pg_f117-e1_1_9_csm1120108.pdf