Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 841 - 860 of 1341
PDFAdvanced Motor Condition Monitoring Device

... frequency 45 to 245 Hz Since wave Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit Not including accuracy variation of CTs The power frequency must be within the rated...

https://www.omron.com.vn/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf

PDFInsulation Resistance Monitoring Device

...fications Measurement range 0.1 to 99.9 MΩ (0.0 MΩ for less than 0.1 MΩ) Measuring accuracy ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) Megger volta...

https://www.omron.com.vn/data_pdf/cat/k7ge-mg_n225-e1_2_2_csm1106906.pdf

PDFHeater Condition Monitoring Device

...e not included. Measurement accuracy Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...

https://www.omron.com.vn/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf

PDFSmar t Power Supply S8AS2 Smart Power Supply

...l voltage 2 V or less Output voltage display Display range: 16.3 to 32.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output current Display range: 0.0 to 20.0 A Bra...

https://www.omron.com.vn/data_pdf/cat/s8as2_t243-e1_2_1_csm1132735.pdf

PDFSmart Power Supply S8AS A New Type of Power Supply...

...dual voltage: 2 V max. Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output ...

https://www.omron.com.vn/data_pdf/cat/s8as_t228-e1_9_6_csm1381.pdf

PDFDigital Multicircuit Protector

...dual voltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current ...

https://www.omron.com.vn/data_pdf/cat/s8m_t232-e1_3_4_csm2006.pdf

PDF:arQLQJ6\PEROV Precautions fRU6DfH8VH 6SHFLILFDWLR...

... 1O7 86E + 4 transfer output 5 - 5 Event Inputs and Transfer output EV EV + 4-20 mADC transfer /RDGŸPD[ output 4 5 - 4-20 mADC /RDGŸPD[ ‡ $KHDWHUEXUQRXWDODUPKHDWHUVKRUWDODUPKHDWHURYH...

https://www.omron.com.vn/data_pdf/mnu/e5cn-h_inst-5639658-0a.pdf

PDF●仕様 形 ES1-L-N 注意 形式 形ES1-LP3-N/形ES1-LP10-N

...す。 パソコンと接続するためのマイクロUSBケーブルは、お客様でご準備ください。 取付金具 2m アルミニウム rdg:読み取り値 *1:電流出力4∼20mAは、 すべて0∼500℃でスケーリングしています。 出荷時のス...

https://www.omron.com.vn/data_pdf/mnu/es1-l_(l)-n_inst-gz0000492904.pdf

PDF(16)フロントシートの剥がれ・破れが生じた状態で使用しないで 取り付け方法

...イン Plus 黒(マンセル N1.5) DIN レールメインユニット:約 156g プローブユニット:約 63g 0.1 ∼ 99.9MΩ(0.1MΩ未満は 0.0MΩ) ±5%rdg±1digit (周囲温度 -10 ∼ 55℃、周囲湿度 25 ∼ 65%RH) 操作電源:...

https://www.omron.com.vn/data_pdf/mnu/k7ge-mg_inst-5641253-5a.pdf

PDF1 Overview 2 Device Components Motor Condition 3

... Acceleration: ± 0.1 G, velocity: ± 2.25 mm/s, temperature: ± 6°C, insulation resistance: ± 35% rdg., current: ± 10% F. S. Safety standards: UL 61010-2-030 (Listing), CSA*1, Korean Radio Law,...

https://www.omron.com.vn/data_pdf/mnu/n219-e1-16_k6cm.pdf

PDF1 Overview 2 Procedure Insulation Resistance 3

....9 MΩ. 0.1 0.0 0.1 M 1M 10 M 99.9 M Measurement value The measuring accuracy is as follows: ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) "...

https://www.omron.com.vn/data_pdf/mnu/n224-e1-07_k7ge-mg.pdf

PDF1 Overview 2 Procedures Heater Condition 3

...n CTs are not included. A A-1-1 K7TM Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...

https://www.omron.com.vn/data_pdf/mnu/n227-e1-07_k7tm.pdf

PDF1 Overview 2 Procedures Power Line Data Generator ...

... frequency 45 to 245 Hz Since wave Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit • Not including accuracy variation of CTs • The power frequency must be within the r...

https://www.omron.com.vn/data_pdf/mnu/n233-e1-04_k7dd.pdf

PDF1 Features and Functions 2 Specifications

...ax. Display functions Output voltage display Display range: 16.3 to 32.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 20.0 A Peak output...

https://www.omron.com.vn/data_pdf/mnu/t242-e1-01_s8as2.pdf

PDFDigital Multicircuit Protector S8M

...°C, Over-temperature Output Display functions Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Input voltage display/ detection Setting range: 0.5 to 3.8 A (in 0.1-A units)...

https://www.omron.com.vn/data_pdf/mnu/z241-e1-03_s8m.pdf

PDFSmart Power Supply S8AS USER'S MANUAL

...ent: 0.1 mA max., Residual voltage: 2 V max. Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Branch output display range: 0.0 to 4.0 A Peak output current display range: ...

https://www.omron.com.vn/data_pdf/mnu/z269-e1-07_s8as.pdf

PDF[-] K3NP データシート

...500 ■定格 ■性能 電源電圧 AC100∼240Vタイプ : AC100∼240V(50/60Hz) DC12∼24Vタイプ : DC12∼24V 計測精度(at23±5℃) ±0.08%rdg±1ディジット 許容電圧変動範囲 電源電圧の85∼110% 計測範囲 消費電力 *...

https://www.fa.omron.co.jp/data_pdf/closed/cat/k3np_1.pdf

PDF[-] K3NV データシート

...直流電圧 レンジ 計測範囲 入力インピーダンス 確度 瞬時過負荷(30秒) a lc 0.00∼199.99mV 1MΩ以上 ±0.1%rdg±5ディジット以下 ±200V b lc 0.000∼19.999mV 1MΩ以上 ±0.1%rdg±5ディジット以下 ±200V...

https://www.fa.omron.co.jp/data_pdf/closed/cat/k3nv_1.pdf

PDF[-] TP200-A データシート

...ランジスタ (NPN)、リレー接点 計測範囲 モードA、 C:10ms∼3,200s、最小計測間隔100ms モードB:100ms∼3,200s 計測精度 0.1%rdg±1digit 最小パルス幅 ■定格項目 T2 T1 形式 リレー接点 AC100∼240V(50/...

https://www.fa.omron.co.jp/data_pdf/closed/cat/tp200-a.pdf

PDF[-] ZP-C データシート

...電圧入力時:±(0.1%F.S.+1digit) 電流入力時:±(0.2%F.S.+1digit) 直線性 ±(0.02%F.S.+1digit) 以下 温度特性 *2 ±(0.005%of rdg+0.5digit)/℃以下表示更新周期 表示 アナログ入力 制御入力 ...

https://www.fa.omron.co.jp/data_pdf/closed/cat/zp-c_ds_j_1_1.pdf

Results 841 - 860 of 1341