Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 841 - 860 of 1516
PDFSmart Power Supply S8AS A New Type of Power Supply...

...dual voltage: 2 V max. Output voltage display Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current display Branch output display range: 0.0 to 4.0 A Peak output ...

https://www.omron.com.au/data_pdf/cat/s8as_t228-e1_9_6_csm1381.pdf

PDFDigital Multicircuit Protector

...dual voltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current ...

https://www.omron.com.au/data_pdf/cat/s8m_t232-e1_3_4_csm2006.pdf

PDF:arQLQJ6\PEROV Precautions fRU6DfH8VH 6SHFLILFDWLR...

... 1O7 86E + 4 transfer output 5 - 5 Event Inputs and Transfer output EV EV + 4-20 mADC transfer /RDGŸPD[ output 4 5 - 4-20 mADC /RDGŸPD[ ‡ $KHDWHUEXUQRXWDODUPKHDWHUVKRUWDODUPKHDWHURYH...

https://www.omron.com.au/data_pdf/mnu/e5cn-h_inst-5639658-0a.pdf

PDF●仕様 形 ES1-L-N 注意 形式 形ES1-LP3-N/形ES1-LP10-N

...す。 パソコンと接続するためのマイクロUSBケーブルは、お客様でご準備ください。 取付金具 2m アルミニウム rdg:読み取り値 *1:電流出力4∼20mAは、 すべて0∼500℃でスケーリングしています。 出荷時のス...

https://www.omron.com.au/data_pdf/mnu/es1-l_(l)-n_inst-gz0000492904.pdf

PDF(16)フロントシートの剥がれ・破れが生じた状態で使用しないで 取り付け方法

...イン Plus 黒(マンセル N1.5) DIN レールメインユニット:約 156g プローブユニット:約 63g 0.1 ∼ 99.9MΩ(0.1MΩ未満は 0.0MΩ) ±5%rdg±1digit (周囲温度 -10 ∼ 55℃、周囲湿度 25 ∼ 65%RH) 操作電源:...

https://www.omron.com.au/data_pdf/mnu/k7ge-mg_inst-5641253-5a.pdf

PDF1 Overview 2 Device Components Motor Condition 3

... Acceleration: ± 0.1 G, velocity: ± 2.25 mm/s, temperature: ± 6°C, insulation resistance: ± 35% rdg., current: ± 10% F. S. Safety standards: UL 61010-2-030 (Listing), CSA*1, Korean Radio Law,...

https://www.omron.com.au/data_pdf/mnu/n219-e1-16_k6cm.pdf

PDF1 Overview 2 Procedure Insulation Resistance 3

....9 MΩ. 0.1 0.0 0.1 M 1M 10 M 99.9 M Measurement value The measuring accuracy is as follows: ±5% rdg. ±1 digit (at ambient temperature -10 to 55°C and ambient humidity 25% to 65%) "...

https://www.omron.com.au/data_pdf/mnu/n224-e1-07_k7ge-mg.pdf

PDF1 Overview 2 Procedures Heater Condition 3

...n CTs are not included. A A-1-1 K7TM Repeat accuracy of resistance value (reference value): ±1% rdg ±1 digit Conditions: • When sine waves are input continuously • Variations in CTs are not i...

https://www.omron.com.au/data_pdf/mnu/n227-e1-07_k7tm.pdf

PDF1 Overview 2 Procedures Power Line Data Generator ...

... frequency 45 to 245 Hz Since wave Current Absolute accuracy: 0.5%FS±1digit Repeat accuracy: ±1%rdg±1digit • Not including accuracy variation of CTs • The power frequency must be within the r...

https://www.omron.com.au/data_pdf/mnu/n233-e1-04_k7dd.pdf

PDFDigital Multicircuit Protector S8M

...°C, Over-temperature Output Display functions Display range:17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Input voltage display/ detection Setting range: 0.5 to 3.8 A (in 0.1-A units)...

https://www.omron.com.au/data_pdf/mnu/z241-e1-03_s8m.pdf

PDFSmart Power Supply S8AS USER'S MANUAL

...ent: 0.1 mA max., Residual voltage: 2 V max. Display range: 17.0 to 30.0 V Display accuracy: 2% rdg ±1 digit max. Branch output display range: 0.0 to 4.0 A Peak output current display range: ...

https://www.omron.com.au/data_pdf/mnu/z269-e1-07_s8as.pdf

PDFCSM_D5V_DS_TW_1_8 1 接觸式變位感測器D5V

...閱本公司網站(http://www.omron.com.tw)。 和數位控制電錶的連接範例產品名稱電壓/電流控制電錶型號K3HB-XAD-@@@ 特點 ˙準確度±0.1%rdg±1位數以下 ˙備有接點、電晶體、BCD、通訊、線性等各種輸出模組 ˙...

https://www.omron.com.tw/data_pdf/cat/d5v_ds_tw_1_8.pdf

PDF1 Infrared Thermosensor ES1-N Measure Workpieces w...

...(24 VDC, Using laser pointer) Cable length 2 m±5 cm Measurement accuracy USB output •Within±(-8%rdg+1)°C (Measurement temperature: -50 to 0°C) •Within±1°C (0 to 200°C) •Within±0.5%...

https://www.omron.com.tw/data_pdf/cat/es1-n_h227-e1_4_4_csm1059198.pdf

PDFCSM_K3HB-R_DS_TW_16_2 1 旋轉脈衝電錶K3HB-R

...5SC(01)、 壓接端子(廣瀨電機:HR31-SC-121))。 *3 5 K3HB-R ■性能可顯示範圍-19999~99999 測量精度(at23±5℃) 功能F1、F6:±0.006%rdg±1數值(感測器為電壓脈衝/開路集極型時) 功能F2~F5:±0...

https://www.omron.com.tw/data_pdf/cat/k3hb-r_ds_tw_16_2.pdf

PDFCSM_K3HB-V_DS_E_11_6 1 Weighing Indicator K3HB-V

...ambient temperature of 23±5°C. For all ranges,10% or less of max. input±0.1% FS. 2. The letters“rdg”mean“reading.” The area shown in dark shading indicates the factory setting. „Load Cell Wir...

https://www.omron.com.tw/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf

PDFCSM_K3HB-V_DS_TW_11_3 1 荷重計、mV電錶K3HB-V

...(測量範圍與精度) 註1.環境溫度23±5℃下保證測量精度。 但輸入範圍在輸入最大值的10%以下時,誤差為±0.1%FS。 2.字母rdg為讀數值。 為購買本產品時的設定狀態。 ■荷重計配線例 ■scaling範例 (使用外部...

https://www.omron.com.tw/data_pdf/cat/k3hb-v_ds_tw_11_3.pdf

PDFCSM_K3HB-X_DS_E_12_6 1 Process Indicator K3HB-X

... resistance of approximately 1 MΩbetween the input ter- minals if they are open. 2. The letters“rdg”mean“reading”and refer to the input error. 3. The value (0.5 VA CT) is the VA consumption o...

https://www.omron.com.tw/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf

PDFCSM_K3HB-X_DS_TW_12_3 1 電壓/電流控制電錶K3HB-X

...免輸入端子間成為開路。 開路會導致顯示產生大幅偏差。 如為開路狀態,請在輸入端子間連接1MΩ左右的電阻。 2.字母rdg為讀數值,表示相對於輸入的誤差。 *1.K3HB-XVA@@型適用UL安全規格時,輸入施加電壓為A...

https://www.omron.com.tw/data_pdf/cat/k3hb-x_ds_tw_12_3.pdf

PDF1 Motor Condition Monitoring Device

...Ω, Leakage current: 0.0 mA to 200.0 mA Measurement absolute accuracy Insulation resistance ±35% rdg±2 digit (when the insulation resistance is 0.2 MΩmax.), when a 200-V/7.5-kW max. motor is u...

https://www.omron.com.tw/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf

PDF馬達狀態監控機器 K6CM系列 ●追加推出亦適用於使用變頻器環境的機種。

...5.在EIP CPU版本1.2以上時才能使用。 測量範圍絕緣阻抗:0.000M~1.000MΩ, 漏電電流:0.0mA~200.0mA 測量絕對精度絕緣阻抗 ±35%rdg±2digit(絕緣阻抗0.2MΩ以下時),使用200V/7.5kW以下的馬達時*1 ±35...

https://www.omron.com.tw/data_pdf/cat/k6cm_sgte-660_tw_3_5.pdf

Results 841 - 860 of 1516

Select Country in