E5CC-CQ3ASM-007 | OMRON Industrial Automation

...t Control output 2 Voltage output (for driving SSR) Voltage output (for driving SSR) 1 point 12 VDC±20%, Maximum load current: 21 mA, PNP, with short-circuit protection circuit Linear current...

https://www.ia.omron.com/product/item/3093/

E5CC-CQ3DSM-000 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Item list of E5CC, E5CC-B, E5CC-U Ratings / Performance Dimensions Connection diagram Input...

https://www.ia.omron.com/product/item/3094/

E5CC-CQ3DSM-001 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Number of event input 2 point Heater burnout /SSR failure detector 1 point Item list of E5C...

https://www.ia.omron.com/product/item/3095/

E5CC-CQ3DSM-002 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Heater burnout /SSR failure detector 1 point Communications method RS-485 (two-wire, half d...

https://www.ia.omron.com/product/item/3096/

E5CC-CQ3DSM-003 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Heater burnout /SSR failure detector 2 points Communications method RS-485 (two-wire, half ...

https://www.ia.omron.com/product/item/3097/

E5CC-CQ3DSM-004 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Number of event input 2 point Communications method RS-485 (two-wire, half duplex) Item lis...

https://www.ia.omron.com/product/item/3098/

E5CC-CQ3DSM-005 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Number of event input 4 point Item list of E5CC, E5CC-B, E5CC-U Ratings / Performance Dimen...

https://www.ia.omron.com/product/item/3099/

E5CC-CQ3DSM-006 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Number of transfer output 1 point Number of event input 2 point Item list of E5CC, E5CC-B, ...

https://www.ia.omron.com/product/item/3100/

E5CC-CQ3DSM-007 | OMRON Industrial Automation

...driving SSR) Number of total auxiliary output 3 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Number of event input 2 point Remote SP input Yes Item list of E5CC, E5CC-B, E5CC-U Ratings...

https://www.ia.omron.com/product/item/3101/

E5CC-CX0ASM-000 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3102/

E5CC-CX0AUM-000 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3103/

E5CC-CX0DSM-000 | OMRON Industrial Automation

... output 1 Linear current output Control output 2 None Power supply voltage 24 VAC (50/60 Hz) 24 VDC Item list of E5CC, E5CC-B, E5CC-U Ratings / Performance Dimensions Connection diagram Input...

https://www.ia.omron.com/product/item/3104/

E5CC-CX0DUM-000 | OMRON Industrial Automation

... output 1 Linear current output Control output 2 None Power supply voltage 24 VAC (50/60 Hz) 24 VDC Item list of E5CC, E5CC-B, E5CC-U Ratings / Performance Dimensions Connection diagram Input...

https://www.ia.omron.com/product/item/3105/

E5CC-CX1AUM-000 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3106/

E5CC-CX1DUM-000 | OMRON Industrial Automation

...utput 2 None Number of total auxiliary output 1 point Power supply voltage 24 VAC (50/60 Hz) 24 VDC Item list of E5CC, E5CC-B, E5CC-U Ratings / Performance Dimensions Connection diagram Input...

https://www.ia.omron.com/product/item/3107/

E5CC-CX2ASM-000 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3108/

E5CC-CX2ASM-004 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3109/

E5CC-CX2ASM-005 | OMRON Industrial Automation

...s) Manual reset value 0.0 to 100.0% (in units of 0.1%) Insulation resistance 20 MΩ min. (at 500 VDC) Dielectric strength 3,000 VAC 50/60 Hz 1 min (Between current-carrying terminals of differ...

https://www.ia.omron.com/product/item/3110/

E5CC-CX2ASM-006 | OMRON Industrial Automation

...tput: 4 to 20 mA DC (Load: 500 Ω max., Resolution: approx. 10000) Linear voltage output: 1 to 5 VDC (Load: 1 kΩ min., Resolution: approx. 10000) Accuracy: ±0.3% FS max. Setting method Digital...

https://www.ia.omron.com/product/item/3111/

E5CC-CX2ASM-007 | OMRON Industrial Automation

... Current input: 4 to 20 mA DC, 0 to 20 mA DC (Input Impedance 150 Ω max.) Voltage input: 1 to 5 VDC, 0 to 5 VDC, 0 to 10 VDC (Input Impedance 1 MΩ min.) Accuracy: ±0.2% FS ±...

https://www.ia.omron.com/product/item/3112/