...ata A (–) 2 SDB Send data B (+) Output Output 3 NC Not used - 4 NC Not used - 5 NC Not used - 6 RDA Receive data A (–) Input 7 NC Not used - 8 RDB Receive data B (+) Input 9 NC Not used - Hoo...
https://www.omron.com.vn/data_pdf/mnu/w306-03_c200h-asc11_21_31.pdf
...ance Switch RS-422 Port Pin Allocation 3. RS-422 port FG SG SDB SDA RDB 2. Connector 1, 2, 3... RDA 1. Termination Resistance Switch Set the termination resistance switch to “ON” (upper side)...
... Rear Communications status indicator CPU Unit connector COMM DIP switch for operation settings RDA- RDB+ SDA- SDB+ FG RS-232C connector RS-422A/485 Terminal Block Tighten screws on the ter...
... RS-422A/485, always check the polarity before you make connections. The signal names SDA/B and RDA/B do not always have the same polarity. • Do not turn OFF the power supply while writing th...
https://www.omron.com.vn/data_pdf/mnu/w494-e1-04_cj1w-scu_2.pdf
...s • Always check polarity before connecting RS-422A/485 cables. The polarity of the SDA/SDB and RDA/RDB terminals and signals are reversed for some remote devices. 20 NX-series Communications...
...Serial Communications Option Board Models and Specifications NX-series NX1P2 CPU Unit COMM COMM RDA- RDB+ SDA- SDB+ SHLD SG0 RD SDER SG1 DR RS CS SHLD RS-232C Option Board (NX1W-CIF01) RS-422...
...Net/IP PORIT2 EtherCAT 1 2 OUT ERR Serial Communications Option Board 3-2 VI1 I I1 VI2 I I2 COM RDA- RDB+ SDA- SDB+ SHLD Option Board ERR ERR IN OUT OUT VI1 I I1 VI2 I I2 COM VO1 VO2 COM COMM...
... Rear Communications status indicator CPU Unit connector COMM DIP switch for operation settings RDA- RDB+ SDA- SDB+ FG RS-422A/485 terminal block z RS-422A/485 Terminal Block Tighten screws o...
...: 24 VDC or 24 VAC (50 to 60 Hz) 44 Pin Name 1 2 3 4 5 6 PWR NC SG PWR SD RD Name Pin RS-485 SG RDA(-) SDA(-) NC RDB(+) SDB(+) S8M K3SC-10 K3SC-10 Name Pin 7 8 9 10 11 12 Pin Name 7 (See note...
...Installation, Connections, and Wiring RS-422/RS-485 Port Pin Arrangement Pin No. Name Details RDA(−) Receive data 2 RDB(+) Receive data 3 SDA(−) Send data 4 SDB(+) Send data 5 SG Terminal N...
https://www.omron.com.vn/data_pdf/mnu/z249-e1-12_v680-ca5d0_-v2.pdf
...2 3 4 5 6 7 8 9 1 2 3 4 5 6 K3SC-10 Name Name PWR NC SG PWR SD RD SG RDA(−) SDA(−) NC RDB(+) SDB(+) RS-485 Pin 7 8 9 10 11 12 (See note.) S8AS A(−) B(+) Clamp filter We recommend twisting the...
...1 2 3 4 5 6 7* Terminal name − RD (RXD) SD (TXD) − − − SG (GND) 8 9 10 11 12 13 14 15 − RDB (+) RDA (−) SDB (+) SDA (−) − − − 1 9 Function (Not used) Enters data from the external device. Out...
https://www.omron.com.vn/data_pdf/mnu/z415-e1-08_mx-z2000h-v1.pdf
... name Function 1 2 3 4 5 6 7 − RD (RXD) SD (TXD) − − − SG (GND) 8 9 10 11 12 13 14 15 − RDB (+) RDA (−) SDB (+) SDA (−) − − − (Not used) Enters data from the external device. Outputs data fro...
https://www.omron.com.vn/data_pdf/mnu/z416-e1-08_mx-z2000h-v1.pdf
...No. 7 送信データA SDA 出力 9 21 2 送信データB SDB 出力 5 20 入力 3 受信データA RDA 入力 6 23 出力 4 受信データB RDB 24 出力 送信可 CS 入力 5 信号用接地 SG データセットレディ DR 入力 6 保安用...
https://www.fa.omron.co.jp/data_pdf/closed/cat/e5zd-sdl_1.pdf
...250V 5A max.) H LL PASS HH 18 19 20 21 22 L 23 24 25 出力 NPN Tr. (DC 12∼24V 50mA max.) RS-422 26 RDA -FLK1:RS-232C TERMINATER ON OFF 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 9...
...(5出力) H LL PASS 18 19 20 21 22 24 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 25 26 RDA -FLK1:RS-232C TERMINATER ON OFF 14 15 16 17 18 19 20 21 22 23 24 25 1 2 3 4 5 6 7 8 6 1 -T1:トラ...
...HH 18 19 20 21 22 (右側コネクタは-FLK6の場合のみ) L 23 24 25 出力 NPN Tr. (DC 12∼24V 50mA max.) RS-422 26 RDA -FLK1:RS-232C TERMINATER ON OFF 14 15 16 17 18 19 20 21 22 23 24 25 1 K 3 N ...
...aximum cable length is 15 m. • RS-232C Controller Pin No. Signal name 1 SDB(+) 2 SD/SDA(-) 3 RD/RDA(-) 4 RDB(+) 5 NC 6 NC 7 NC 8 NC 9 GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/fz3series(fourcamera)_inst-5319282-8f(e).pdf
...䈇䇯䊶RS-232C ធ⛯䈜䉎ᄖㇱⵝ⟎ 䉮䊮䊃䊨䊷䊤 䊏䊮No. 1 2 3 4 5 6 7 8 9 ାภฬ SDB(+) SD/SDA(-) RD/RDA(-) RDB(+) NC NC NC NC GND 䇭䇭 䇭 ᓎഀ RS-422↪ RS-232C↪/RS-422↪ RS-232C↪/RS-422↪ RS-422↪ ήធ⛯ ήធ⛯ ήធ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/fz3series(fourcamera)_inst-5319282-8f(j).pdf
...aximum cable length is 15 m. • RS-232C Controller Pin No. Signal name 1 SDB(+) 2 SD/SDA(-) 3 RD/RDA(-) 4 RDB(+) 5 NC 6 NC 7 NC 8 NC 9 GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS...