| Site Search | Product Search | IA Global Search |
... when the status reaches 50% All indicators light up when the status reaches 100% be damaged if wired incorrectly. The H5CC removes these worries. * The H5CC-A11F does not isolate power suppl...
https://www.omron-ap.co.nz/data_pdf/cat/h5cc_l220-e1_3_1_csm1124436.pdf
...ntconsuming components Placed far away from the power supply. Large-currentconsuming components Wired in parallel with largecurrent-carrying components. H7E@-N@P Bypass capacitor H7E@-N@P Pow...
https://www.omron-ap.co.nz/data_pdf/cat/h7e_-n_ds_e_9_6_csm119.pdf
...F the power, and label it to clearly indicate its function. (11) Be sure that all terminals are wired correctly. (12) Do not connect more than two crimp terminals to the same terminal. (13) U...
https://www.omron-ap.co.nz/data_pdf/cat/h8bm-r_ds_e_5_6_csm749.pdf
... M12 connector, the proper tightening torque is from 0.39 to 0.49 N⋅m. • In the case of the pre-wired M12 Smartclick Connector, firmly tighten the connector to the mating complete mark positi...
https://www.omron-ap.co.nz/data_pdf/cat/k3cv_h243-e1_3_1_csm1132260.pdf
...sistor output on models with L1 and L2 are connected internally. Depending on how the common is wired for externally connected devices, unwanted current paths for the linear output signal in ...
https://www.omron-ap.co.nz/data_pdf/cat/k3gn_ds_e_7_2_csm253.pdf
... signal. The data will not go LOW. • The K3HB BCD output model has an open collector output, so wired OR connection is possible REQ. (1) K3HB (1) Programmable Controller REQ. (2) K3HB (2) REQ...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-c_ds_e_17_5_csm259.pdf
...roller REQ. (2) K3HB (2) REQ. (3) DATA (including POL and OVER) and DATA VALID can be used in a wired OR. RUN, HH, H, PASS, L, and LL are always output, with or without a REQUEST signal. Do n...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-h_ds_e_14_6_csm260.pdf
... signal. The data will not go LOW. • The K3HB BCD output model has an open collector output, so wired OR connection is possible REQ. (1) K3HB (1) Programmable Controller REQ. (2) K3HB (2) REQ...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-p_ds_e_16_5_csm261.pdf
... signal. The data will not go LOW. • The K3HB BCD output model has an open collector output, so wired OR connection is possible REQ. (1) K3HB (1) Programmable Controller REQ. (2) K3HB (2) REQ...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-r_ds_e_16_5_csm262.pdf
...roller REQ. (2) K3HB (2) REQ. (3) DATA (including POL and OVER) and DATA VALID can be used in a wired OR. RUN, HH, H, PASS, L, and LL are always output, with or without a REQUEST signal. Do n...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-s_ds_e_11_6_csm263.pdf
...roller REQ. (2) K3HB (2) REQ. (3) DATA (including POL and OVER) and DATA VALID can be used in a wired OR. RUN, HH, H, PASS, L, and LL are always output, with or without a REQUEST signal. Do n...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-v_ds_e_11_6_csm264.pdf
...roller REQ. (2) K3HB (2) REQ. (3) DATA (including POL and OVER) and DATA VALID can be used in a wired OR. RUN, HH, H, PASS, L, and LL are always output, with or without a REQUEST signal. Do n...
https://www.omron-ap.co.nz/data_pdf/cat/k3hb-x_ds_e_12_6_csm254.pdf
...By keeping a computer or PLC continuously connected, you can monitor the state of a motor. (pre-wired cable) *4 Object monitored K6CM-CI Output signal (transistor output) 1.5 kW to 300 kW (40...
https://www.omron-ap.co.nz/data_pdf/cat/k6cm_n218-e1_3_1_csm1060693.pdf
...By keeping a computer or PLC continuously connected, you can monitor the state of a motor. (pre-wired cable) *3 Object monitored K6CM-CI Output signal (transistor output) 1.5 kW to 300 kW (40...
https://www.omron-ap.co.nz/data_pdf/cat/k6cm_n218-e1_5_4_csm1060693.pdf
...surable. (I) 19 and 20 CH2 CT input The CT connected to the heater current measurement point is wired to this terminal, and the K7TM measures the heater current. This is the second input of t...
https://www.omron-ap.co.nz/data_pdf/cat/k7tm_n228-e1_3_3_csm1115712.pdf
...orrectly if the DIP switch setting and the wiring do not agree. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. Voltage...
https://www.omron-ap.co.nz/data_pdf/cat/k8ak-pa_n186-e1_3_7_csm1020916.pdf
...ration Methods Connections Input Connect using L1, L2, and L3. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. L1 L2 L...
https://www.omron-ap.co.nz/data_pdf/cat/k8ak-ph_n183-e1_3_6_csm1020913.pdf
...orrectly if the DIP switch setting and the wiring do not agree. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. Voltage...
https://www.omron-ap.co.nz/data_pdf/cat/k8ak-pm_n185-e1_3_7_csm1020915.pdf
...orrectly if the DIP switch setting and the wiring do not agree. Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. Voltage...
https://www.omron-ap.co.nz/data_pdf/cat/k8ak-pw_n184-e1_3_8_csm1020914.pdf
...re the input to the L1, L2, and L3 terminals (3-phase, 3-wire). Make sure the phase sequence is wired correctly. The Unit will not operate normally if the phase sequence is incorrect. Voltage...
https://www.omron-ap.co.nz/data_pdf/cat/k8ds-pa_n193-e1_2_5_csm1020923.pdf