| Site Search | Product Search | IA Global Search |
... 5 V DC, Load: 1 kΩ min., Resolution: Approx. 10,000 Setting method Digital setting using front panel keys Indication method 11-segment digital display, individual indicators, and bar display...
https://www.omron-ap.co.nz/products/family/3668/specification.html
...roller. The E58-CIFQ2 USB-Serial Conversion Cable is required to connect to the port on the top panel. The E58-CIFQ2 USB-Serial Conversion Cable and E58-CIFQ2-E Communications Conversion Cabl...
https://www.omron-ap.co.nz/products/family/3669/dimension.html
... 5 V DC, Load: 1 kΩ min., Resolution: Approx. 10,000 Setting method Digital setting using front panel keys Indication method 11-segment digital display, individual indicators, and bar display...
https://www.omron-ap.co.nz/products/family/3669/specification.html
...l / CAD / Software last update: December 27, 2019 (Unit: mm) Controllers E5CD-800 • Recommended panel thickness is 1 to 5 mm. • Group mounting is not possible in the vertical direction. (Main...
https://www.omron-ap.co.nz/products/family/3671/dimension.html
... certification is required, use these CTs. Adapter Model Y92F-45 Note:Use this Adapter when the panel has already been prepared for an E5B[] Controller. Waterproof Cover Model Y92A-48N Mounti...
...: 0.1 mA max. Current flow: Approx. 7 mA per contact Setting method Digital setting using front panel keys Indication method 11-segment digital display, individual indicators, and bar display...
https://www.omron-ap.co.nz/products/family/3671/specification.html
...l / CAD / Software last update: December 27, 2019 (Unit: mm) Controllers E5ED-800 • Recommended panel thickness is 1 to 8 mm. • Group mounting is not possible in the vertical direction. (Main...
https://www.omron-ap.co.nz/products/family/3672/dimension.html
...: 0.1 mA max. Current flow: Approx. 7 mA per contact Setting method Digital setting using front panel keys Indication method 11-segment digital display, individual indicators, and bar display...
https://www.omron-ap.co.nz/products/family/3672/specification.html
...last update: December 18, 2023 General Specification Item NJ501-[][][][] Enclosure Mounted in a panel Grounding Method Ground to less than 100 Ω Dimensions (height×depth×width) 90 mm × 90 mm ...
https://www.omron-ap.co.nz/products/family/3679/specification.html
... • EMI (radiated emissions) conform to Class B when this Power Supply is installed in a control panel. • EN/IEC 61558-2-16 The S8VK-X was designed based on EN/IEC 61558-2-16. Currentl...
https://www.omron-ap.co.nz/products/family/3687/specification.html
...tware last update: July 1, 2025 General Specification Item Specification Enclosure Mounted in a panel Grounding Method Ground to less than 100 Ω Dimensions (height × depth × width) 100 mm × 1...
https://www.omron-ap.co.nz/products/family/3698/specification.html
... last update: December 1, 2023 General Specifications Item Specification Enclosure Mounted in a panel Grounding method Ground to 100 Ω or less Operating environment Ambient operating temperat...
https://www.omron-ap.co.nz/products/family/3699/specification.html
... 30 pins, Unit: 30 pins) NX-AUX02 DIN Track Insulation Spacers A Spacer to insulate the control panel from the DIN Track. To insulate the EtherCAT Slave Terminal from the control ...
...al and Mechanical Specifications Item Specification Model NX102-[][][][] Enclosure Mounted in a panel Dimensions (mm) *1 72 × 100 × 90 mm (W×H×D) Weight *2 390 g max. Unit power supply Power ...
https://www.omron-ap.co.nz/products/family/3705/specification.html
... specifications of the High-speed Analog Input Units. Item Specification Enclosure Mounted in a panel Grounding methods Ground of 100 Ω or less Operating environment Ambient operating tempera...
https://www.omron-ap.co.nz/products/family/3708/specification.html
...red for RCM and KC compliance. General Specifications Item Specification Enclosure Mounted in a panel (open) Grounding method Ground to 100 Ω or less Operating environment Ambient operating t...
https://www.omron-ap.co.nz/products/family/3719/specification.html
...ction describes the Motion Controller specifications. Item Specification Enclosure Mounted in a panel Grounding Method Ground to less than 100 Ω Operating Environment Ambient Operating Temper...
https://www.omron-ap.co.nz/products/family/3725/specification.html
...ction describes the Motion Controller specifications. Item Specification Enclosure Mounted in a panel Grounding Method Ground to less than 100 Ω. Operating Environment Ambient Operating Tempe...
https://www.omron-ap.co.nz/products/family/3726/specification.html
...ction describes the Motion Controller specifications. Item Specification Enclosure Mounted in a panel Grounding Method Ground to less than 100 Ω. Operating Environment Ambient Operating Tempe...
https://www.omron-ap.co.nz/products/family/3727/specification.html
... KC (Korean radio regulation). General Specifications Item Specification Enclosure Mounted in a panel (open type) Operating environment Ambient operating temperature 0 to 55°C Ambient operati...
https://www.omron-ap.co.nz/products/family/3735/specification.html