Site Search | Product Search | IA Global Search |
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input DC voltage/current A/D conversion method Sequential comparison system External power supp...
https://www.omron-ap.co.in/products/family/1536/specification.html
...l Boards Optional Boards Sensor Power Supply/Output Boards Relay/Transistor Output Boards Event Input Boards 1. Input Sensor Code NB: NPN input/voltage pulse input ...
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC ±10%, 80 m...
https://www.omron-ap.co.in/products/family/1538/specification.html
...al Boards Optional Board Sensor Power Supply/Output Boards Relay/Transistor Output Boards Event Input Boards 1. Input Sensor Code NB: NPN input/voltage pulse input ...
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC 10%, 80 mA...
https://www.omron-ap.co.in/products/family/1539/specification.html
...al Boards Optional Board Sensor Power Supply/Output Boards Relay/Transistor Output Boards Event Input Boards 1. Input Sensor Code NB: NPN input/voltage pulse input ...
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input No-voltage contact, voltage pulse, open collector External power supply 12 VDC±10% 80 mA ...
https://www.omron-ap.co.in/products/family/1540/specification.html
...l Boards Optional Boards Sensor Power Supply/Output Boards Relay/Transistor Output Boards Event Input Boards 1. Input Sensor Code TA: Temperature input Thermocouple ...
.../DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D ...
https://www.omron-ap.co.in/products/family/1541/specification.html
...e: 1. The models with the suffix "-01TS" or "-02TS are the PNP type only. 2. The test input logic is inverted for the models with the suffix "-01TS". 3. Reset mode is fixe...
... *3, Maximum capacity load 1 μF *4 Output operation mode Safety output: On when receiving light Input voltage PNP output Test input: ON voltage: Vs-3 V to Vs (short circuit current: ...
https://www.omron-ap.co.in/products/family/1581/specification.html
... Internal circuit power supply 24 VDC, 230 mA 24 VDC, 280 mA I/O power supply *2 24 VDC, 40 mA (Input) 120 mA (Output) 24 VDC, 80 mA (Input) 150 mA (Output) Overvoltage category II N...
https://www.omron-ap.co.in/products/family/1625/specification.html
...mA 24 VDC, 110 mA 24 VDC, 100 mA 24 VDC, 110 mA I/O power supply * 24 VDC, 70 mA 24 VDC, 50 mA (Input) 130 mA (Output) 24 VDC, 80 mA (Input) 130 mA (Output) 24 VDC, 50 mA (...
https://www.omron-ap.co.in/products/family/1626/specification.html
...esidual voltage of 0.4 V max. at 50-mA load current OFF current: 0.5 mA max. External diagnosis input Input NPN Models Emission OFF: Shorted to 0 V or 0.5 V max. (source current: 30 ...
https://www.omron-ap.co.in/products/family/1629/specification.html
...CPU Unit CJ1M-CPU13 *1 1 0.580 A --- I/O Control Unit CJ1W-IC101 1 0.020 A --- Basic I/O Units (Input Units) CJ1W-ID211 2 0.080 A --- CJ1W-ID231 2 0.090 A --- Basic I/O Units (Output Units) C...
https://www.omron-ap.co.in/products/family/1639/specification.html
...ils and applicable conditions for these standards. Process I/O Units Isolated-type Thermocouple Input Units Unit classi- fica- tion Product name Input points Signal range selec- tion...
...alog / Manual / CAD / Software last update: April 1, 2014 CJ1W-PTS15 Isolated-type Thermocouple Input Unit Item Specifications Model CJ1W-PTS15 Applicable Controller CJ Series Unit classifica...
https://www.omron-ap.co.in/products/family/1644/specification.html
... OMRON representative for further details and applicable conditions for these standards. Analog Input Units Unit type: CJ1 Special I/O Units Signal range selection: Set separately for ea...
... Specifications Dimensions Catalog / Manual / CAD / Software last update: March 11, 2019 Analog Input Units CJ1W-AD041-V1/AD081-V1/AD042 Item CJ1W-AD041-V1 CJ1W-AD081-V1 CJ1W-AD042 Unit type ...
https://www.omron-ap.co.in/products/family/1645/specification.html
...resentative for further details and applicable conditions for these standards. Isolated-type DC Input Units Unit classi- fication Product name Input points Signal range selection Con...