| Site Search | Product Search | IA Global Search |
...image input timing. 1-3 Starting the Sensor 1 2 Adjust the brightness. Adjust the shutter speed so that the Sensor can capture images of the measurement object at a suitable brightness. If th...
https://www.fa.omron.co.jp/data_pdf/mnu/fq2-s__-___(quickstartupguide)_inst-4012069-0c.pdf
...and mount the Sensor at the correct position. 2 Adjust the brightness. Adjust the shutter speed so that the Sensor can capture images of the measurement object at a suitable brightness. If th...
https://www.fa.omron.co.jp/data_pdf/mnu/fq2-s______-___(quickstartupguide)_inst-2243372-0c.pdf
...ndling · Do not peel off or damage the waterproof sheet attached to the side of the unit. Doing so may result in dirt, dust or water droplet entering inside the device, causing a failure of t...
https://www.fa.omron.co.jp/data_pdf/mnu/fq2-s_______inst-9908929-0j.pdf
... not use the product outdoors or in environments exposed to direct sunlight. ・ Install the unit so that air can flow freely through its cooling vents. ・ Install the product away from high-v...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-m08_inst-1636843-6f.pdf
... (49) 7032-811-199 Camera cable connector Camera FZ-SC2M FZ-S2M *The camera cable is polarized, so, make sure that the end bearing a name plate is connected to the Controller. OMRON ELECTRONI...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-sc2m_s2m_inst-2269008-0b.pdf
...847-843-7900/Fax: (1) 847-843-7787 Approx. 85g (including base) *The camera cable is polarized, so, make sure that the end bearing a name plate is connected to the Controller. *When connectin...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-sc5m3_s5m3_inst-3126677-1a.pdf
...Name plate Camera cable FZ-SC/S connector *The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a name plate is connected to the controller. Suitability for...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-sc_s_inst-9066829-8a.pdf
...-ku, NL-2132 JD Hoofddorp Kyoto. 600-8530 JAPAN The Netherlands *The camera cable is polarized, so, make sure that the end bearing a name plate is connected to the Controller. Suitability for...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-sfc_sf_spc_sp_inst-0185689-2c.pdf
... connector Name plate Camera FZ-SHC FZ-SH *The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a name plate is connected to the Controller. OMRON shall not...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-shc_sh_inst-2135165-7a.pdf
...ance Specifications Removal 1. Loosen the screws of the mounting brackets and turn the brackets so that they will not catch on the illumination part of the FZ-SLC100. 102 * 1 6 5 2 0 6 1 - 0 ...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-slc100-dl_inst-1652061-0a.pdf
...S□ Nameplate Intelligent camera FZ-SLC100 *The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a name plate is connected to the controller. NEVER USE THE P...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-slc100_inst-1636848-7d.pdf
...en the screws of the mounting brackets with the provided hexagonal wrench and turn the brackets so that they will not catch on the illumination part of the FZ-SLC15. 1.5 Performance Specifica...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-slc15-dl_inst-9442174-2a.pdf
...-847-843-7787 Intelligent camera FZ-SLC15 *The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a name plate is connected to the controller. ASIA-PACIFIC OM...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-slc15_inst-1652099-8c.pdf
...meplate Automatic focus camera FZ-SZC100 ※ The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a nameplate is connected to the Controller FZseries. NEVER U...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-szc100_inst-1641749-6a.pdf
...ameplate Automatic focus camera FZ-SZC15 ※ The camera cable (FZ-VS,FZ-VSL,FZ-VSB) is polarized, so, make sure that the end bearing a nameplate is connected to the Controller FZseries. NEVER U...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-szc15_inst-0994985-7a.pdf
... times each in X, Y, and Z directions for 8 min ※The camera cable FZ-VS□□□ series is polarized, so, make sure that the end bearing a name plate is connected to the controller side. 150 m/s2, ...
https://www.fa.omron.co.jp/data_pdf/mnu/fz-vsj_inst-9470198-2g.pdf
...制御の使用。 特に安全性が要求される用途への使用。 ⃝人命や財産に大きな影響が予測され、 3 SSR uses electronics parts mounting on PCB, so that any dropping and vibration, physical shock beyond t...
https://www.fa.omron.co.jp/data_pdf/mnu/g32a-a_-vd_inst-1151567-8b.pdf
...for Safe Use ●Transpporting Do not use or store the G32A-P in the following transporting. Doing so may result in damage, mulfunction, or detericration of performance characteristics. ・Condit...
https://www.fa.omron.co.jp/data_pdf/mnu/g32a-p_inst-1130399-9c.pdf
...to ground in the end product. Do not use or store the G3NA in the following transporting. Doing so may result in damage, mulfunction, or detericration of performance characteristics. ・Condit...
https://www.fa.omron.co.jp/data_pdf/mnu/g3na_inst-9447124-3a.pdf
...a short-circuit failure and burning. Do not apply short-circuit current to load side of SSR. If so,SSR may explode. Ground Close mounting side by side up to three G3PA SSRs is possible. Up to...
https://www.fa.omron.co.jp/data_pdf/mnu/g3pa_inst-1176300-0c.pdf