| Site Search | Product Search | IA Global Search |
...iven in the following table. Controlling Devices Emergency stop switch Door interlocking switch Limit switch Safety sensor Relay with forcibly guided contacts Contactor Other devices • Discon...
https://www.fa.omron.co.jp/data_pdf/mnu/dst1-id_m(r)d_xd__(__)sl-1_inst-1625834-7i.pdf
...leted 10 to 30 VDC Load Orange *1 Control Output 2 The sensitivity is adjusted to the detection limit of 3750, which maximizes the change with the detector. The threshold is 3750. Workpiece i...
https://www.fa.omron.co.jp/data_pdf/mnu/e2nc-ea__series_inst-3128438-9c.pdf
...tion Transition Charts Whe be di Special functions Linear output correction p. 85 Display digit limit p. 102 Error Output Zero reset memory erout p. 98 p. 95 When all is selected, all special...
...ow Light Intensity) (Reserved) Error (Insufficient Light Intensity) Error (Distance Upper/Lower Limit Value) Warning 13 Index Device ID *3644117-2A* PD2 Index 0 1 2. Process data bit PD0 PD1 ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3as-hf6000_m__(indexlist)_inst-3644117-2a.pdf
...ng value Current scaling Low (4 mA) 50 Current scaling High (20 mA) 6000 20.5 mA (Current upper limit value) 20 mA ON Emission OFF Emission Current Laser OFF * About 800 ms is required until ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3as-hf6000_m__inst-3669664-2d.pdf
... EEPROM memory to save the configuration information. If the memory rewritable time exceeds its limit (100,000 times), the memory error will be displayed and the amplifier unit needs to be re...
https://www.fa.omron.co.jp/data_pdf/mnu/e3c-lda__nseries_inst-5710590-3a.pdf
...0 1. Select [Setting Mode] - [OUT1 Mode] - [Area Detection Mode]. [rst] rst The lower threshold limit is -1999. Cancel ● Area Detection Mode Initialize all settings to the factory-set default...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nc-la__series_inst-4013143-9h.pdf
...uning. Threshold value HIGH: Upper workpiece height + area tolerance Threshold value LOW: Lower limit workpiece height - area tolerance 1. Select [Setting Mode] → [Output1 Mode] → [Area Sensi...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nc-saseries___inst-9908894-4i.pdf
...ion. Not doing so may result in serious accidents. Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. The ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nw-ds_inst-9908973-8c.pdf
...ion. Not doing so may result in serious accidents. Emergency stop circuits, interlock circuits, limit circuits, and similar safety measures must be provided in external control circuits. The ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nw-ect_inst-3731596-0d.pdf
...NK Switching 6000 4000 Hold both for 3 sec. or longer MODE [rst user] [rst] The lower threshold limit is -1999. Cancel Hold both for 3 sec. or longer Hold both for 3 sec. or longer 0. Functio...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-ca0_inst-9531853-8d.pdf
... of the bank selected from BANK1-8. [bank no] 0 2000 Initializing BANKs rst The lower threshold limit is -1999. Cancel MODE [rst user] [rst] The threshold also changes accordingly. CH number ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-ca___inst-9530588-6d.pdf
...ier Unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit (1,000,000times), the memory error appears, in which case you must replace the Amplifier ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-fa_0_series_inst-9543552-6f.pdf
...incident level changes. Displayed Incident Light Level Incident Light Level The lower threshold limit is -1999. Cancel 6000 4000 Executing DPC function/ smart tuning releases the zero reset. ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-fa__an_inst-3116826-5a1.pdf
...ier unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit (1,000,000times), the memory error appears, in which case you must replace the amplifier ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-fa__series_inst-9531335-8e.pdf
...ier Unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit (1,000,000times), the memory error appears, in which case you must replace the Amplifier ...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-ma0_inst-2288326-1e.pdf
...ier unit uses EEPROM to save the configuration information. If memory rewrite count exceeds the limit (1,000,000 times), the memory error appears, in which case you must replace the amplifier...
https://www.fa.omron.co.jp/data_pdf/mnu/e3nx-ma__series_inst-2288325-3c.pdf
...eleased, [ 0rst %ff ] is displayed. The threshold also changes accordingly. The lower threshold limit is -1999. CH common setting CH1/2 individual setting n ptun d sp std delyt%ff Power tunin...
https://www.fa.omron.co.jp/data_pdf/mnu/e3x-mzvseries_inst-3624527-6a.pdf
...eleased, [ 0rst %ff ] is displayed. The threshold also changes accordingly. The lower threshold limit is -1999. Use this function with through-beam type or regressive reflection type. Inciden...
https://www.fa.omron.co.jp/data_pdf/mnu/e3x-zvseries_inst-3624526-8a.pdf
...eleased, [ 0rst %ff ] is displayed. The threshold also changes accordingly. The lower threshold limit is -1999. stnd 100 STND Standard Mode STND 1ms x1 The response time differs when the mutu...
https://www.fa.omron.co.jp/data_pdf/mnu/e3x-zvseries_inst-5637776-4f.pdf