Site Search | Product Search | IA Global Search |
...G ––– 7 Send data SD Output 2 Receive data RD Input 3 Request to send RS Output 4 Clear to send CS Input 5 Data terminal not ready ER Output (20) R/W Head Host computer GR brown SG SG yellow ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z087-e1-01_v630.pdf
...FG (GND) Frame ground 2 SD (TXD) Send data 3 RD (RXD) Receive data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 DR (DSR) Data set ready 7 SG (GND) Signal ground 20 ER (DTR) Data term...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z090-02a_f300.pdf
...Flow control Sets the handshake method. None: No handshaking. Xon/off: Executed by software. RS/CS: Executed using RS and CS lines. T. Timeout Sets the waiting time for the response ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z091-03_f300.pdf
...FG (GND) Frame Ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 DR (DSR) Data Settings Ready 7 SG (GND) Signal Ground 8 CD (DCD) Data ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z104-01_f200.pdf
... --- --- 5 Signal ground SG --- 6 Data set enable DS 7 8 9 Request sending Clear to send --- RS CS --- Host device ← Hand-held Reader Writer Repeat p in the connector section. --- --- Transmi...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z122-e1-01a_v600-ch1d.pdf
...Read data displayed in bit units. Red: Flashes to show error classification (bits 0 to 7 only). CS Indicator Shows results of communications with Data Carrier. Green: Normal completion Red: E...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z129-e1-02_v600-ham42-drt.pdf
... External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F1...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z144-e1-04_f160.pdf
...ignal or common return SG — — 5 Send data SD — Receive data RD Request to send RS Clear to send CS 3 — — 2 7 — 8 Controller Pin Layout (TOP VIEW) Note 1: To prevent an operation error, ground...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z148-e1-06_v670-cd1d-v1_h11_h51(q)_d13f0_(h).pdf
... SG (Signal ground) SG (Signal ground) 4 View from connecting side 5 6 7 RS (Request to send) 8 CS (Clear to send) 9 5-6 Loop back (Short-circuit) 5-2 Wiring the Host (2) Using RS-232C Connec...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z149-e1-02_v690-hmg01a_d8kr01a_l01.pdf
...FG (GND) Frame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Sign...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z150-e1-01_v530-c300e.pdf
...unication Unit enables communications between optical sensors and a host, such as an OMRON PLC (CS-series, CJseries, C200HX/HG/HE, or other OMRON PLC), other manufacturer’s PLCs that support ...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z152-e1-02_e3x-drt21_srt21_cif11.pdf
...rame ground 2 SD (TXD) Send Data 3 RD (RXD) Receive Data 5 4 3 2 1 4 RS (RTS) Request to Send 5 CS (CTS) Clear to Send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Sign...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z158-e1-02d_z500-mc10e_15e.pdf
...he same settings that are set in the personal computer. None* Flow control is not performed. RS/CS Flow control performed by the hardware. Use a cable that connects the Z500 and the RS signal...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z159-e1-02_z500-mc10e_15e.pdf
...01 OMRON Corp. Hood: XM2S-0911 Pin No. Signal 1 FG(GND) 2 3 4 5 6 7 8 9 SD(TXD) RD(RXD) RS(RTS) CS(CTS) NC NC NC SG(GND) Name Protective frame ground Send Data Receive Data Request to Send Cl...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z161-e1-03b_z300_v3.pdf
...gth 7, 8* bit Parity bit None*, even, odd Stop bits 1*, 2 bit Delimiter CR*, LF, CR+LF None* RS/CS Flow control Xon/Xoff None* Value Result Value+Result Out on Hold OUT0* OUT1 OUT setting OUT...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z162-e1-02_z300_v3.pdf
...SD 2 2 RD RD 3 3 SD NC 4 4 ER RDB(RD+) 5 5 SG GND 9 6 DR Hood − 7 RS 8 CS Hood − Use a shielded cable. 62 V530-R160 Operation Manual SECTION 3 Connection to the Host 1:1 Connection (Program...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z169-e1-04_v530-r160e_-r160ep.pdf
... External device Signal Pin SD 2 SD RD 3 RD GND 9 GND Pin Use only shielded cable. 36 Signal RS/CS control cannot be used. Section 4-2 Connecting through the Serial Interface RS-422 Wiring F1...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf
...rame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Sign...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z178-e1-01a_z550.pdf
...(default setting), LF, CR + LF Flow None(default setting) The flow control is not performed. RS/CS The flow control is performed by the hardware.Use a cable that connects the RS signal of the...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z179-01_z550.pdf
...rame ground 2 SD (TXD) Transmission data 3 RD (RXD) Reception data 4 RS (RTS) Request to send 5 CS (CTS) Clear to send 6 NC Not connected 7 NC Not connected 8 NC Not connected 9 SG (GND) Sign...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z189-e1-02_z550-mc10_15.pdf