| Site Search | Product Search | IA Global Search |
...High-speed detection models Water-resistant models E3X-SD@ E3X-NA@ E3X-NA@F E3X-NA@V Model Item Light source (wavelength) Red, 4-element LED (625 nm) Red, 4-element LED (624 nm) Red, 4-elemen...
https://www.fa.omron.co.jp/data_pdf/cat/e3x-sd_na_e401-e1_6_4_csm2185.pdf
...ce. Status of indicators (in L-ON mode) Excess gain Description 999% (10 times) Stable incident light of 110% min. Operation indicator Status of indicators (in L-ON mode) 100% 0% Stable ...
https://www.fa.omron.co.jp/data_pdf/cat/e3x-sd_na_photoelectric_operation_tg_e_7_3_csm442.pdf
...出力トランジスタ ON OFF 動作 負荷 (リレー等) 形E3X-NA41 形E3X-NA8 形E3X-NA41F 形E3X-NA41V 形E3X-NA44V 1 L・ON (LIGHT ON) 4 3 D・ON (DARK ON) 復帰 黒 DC 12 ∼ 24V 制御出力 〔茶−黒間〕 T 茶...
https://www.fa.omron.co.jp/data_pdf/cat/e3x-sd_na_scea-149_6_18.pdf
...e switch) feeling. 7-segment display Revised user interface Conventional model(E3X-HD) The L/D (Light on / Dark on) button present on conventional models is eliminated, reflecting customer ...
https://www.fa.omron.co.jp/data_pdf/cat/e3x-zv_mzv_e600-e1_3_4_csm1109326.pdf
... 度が低く、意 図せずに押してしまうことで誤 動 作の原因になるというお客 様の声を受け、従 来 機 種に搭 載されて た Light on / Dark on 切 替 ボタンを無くしました。 これに 表 示サイズ E3X-ZV 従来...
https://www.fa.omron.co.jp/data_pdf/cat/e3x-zv_mzv_scea-196_3_4.pdf
...NA11 Four times High Performance Series Same level E3X-DA21-S* (Tough Fiber Sensor) Four times, light intensity Capable of 10 μm detection Detection in oily environments E3X-DA11-S* ...
https://www.fa.omron.co.jp/data_pdf/cat/e3x_sd_na_naf_e400-e1_2_2_csm2181.pdf
...h phenomena in the Sensor in real time. • The frequency of sudden failure can be decreased. The light incident level monitor prevents false detection before it happens. • The efficiency of ch...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-_-il__ds_e_3_2_csm1071694.pdf
... axis adjustment. • High stability with unique algorithm that prevents interference of external light. • Models are available with Laser type and IO-Link type. • UL certification (UL60947-5-2...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-_-ul_ds_e_4_1_csm1128419.pdf
...動作表示灯 点灯 (橙) 消灯 動作負荷 (リレー等) 復帰 E3Z-T6□(A) E3Z-R6□ E3Z-D6□ E3Z-L6□ E3Z-B6□ E3Z-LT6□ E3Z-LR6□ L側 (LIGHT ON) ON 出力トランジスタ OFF 安定表示灯 (緑) 入光時 M8コネ...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-_-ul_ds_j_4_1.pdf
...ettings • Groove-type Sensor with groove width of 25 mm. • Models are available with one or two light axes. • Models are available with M8 pre-wired connectors. Be sure to read Safety Precaut...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-g_ds_e_9_5_csm434.pdf
...動作表示灯 点灯 (橙) 消灯 ON 制御出力出力トランジスタ OFF 動作負荷 (リレー等) 復帰 〔茶(①) −黒(④(白(②))間〕 L側 (LIGHT ON) 動作表示灯 (橙) 茶 DC12 ∼ 24V 100mA (制御出力) 黒 ...
...8. Ordering Information Sensors (Refer to Dimensions on page 10.) Sensing method Appearance Red light Connection method Pre-wired (2 m) Model Sensing distance (white paper) 20 mm 40 mm NPN ou...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-ls_ds_e_9_5_csm436.pdf
...形E3Z-LS66 しゃ光時ON 動作表示灯 (橙) 安定表示灯 (緑) 光電センサ主回路 1 2 (制御出力) 4 L側 (LIGHT ON) FGSモード FAR VERY FAR 桃 DC12 ∼ 24V FGSモード負荷(リレー) 黒 100mA 以下 BGSモ...
...LL Ordering Information Sensors (Refer to Dimensions on page 11.) Sensing method Appearance Red light Connection method Response time Pre-wired (2 m) Through-beam (Emitter + Receiver) 60 m Co...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-lt_lr_ll_ds_e_7_5_csm2158.pdf
... OFF 負荷動作 (リレー等) 復帰 〔茶(①) −黒(④)間〕 動作切替スイッチ 出力回路 〈透過形の受光器〉 〈回帰反射形〉 L側 (LIGHT ON) 動作表示灯 (橙) 1 安定表示灯 (緑) (制御出力) 黒 4 光...
https://www.fa.omron.co.jp/data_pdf/cat/e3z-lt_lr_ll_sceb-059_1_24.pdf
... axis adjustment. • High stability with unique algorithm that prevents interference of external light. For the most recent information on models that have been certified for safety standards,...
https://www.fa.omron.co.jp/data_pdf/cat/e3z_ds_e_18_9_csm438.pdf
...-L63 形E3Z-L68 出力回路 〈透過形の受光器〉 〈回帰反射形〉 〈拡散反射形〉 〈限定反射形〉 1 動作表示灯 (橙) L側 (LIGHT ON) 安定表示灯 (緑) (制御出力) 黒 4 光電センサ主回路 ZD 3 DC12 ∼ 2...
...ion of a = 30 0 mm. (2)Move the SENSITIVITY adjuster to the MAX position and make sure that the LIGHT and STABILITY indicators of the amplifier turn ON. If the LIGHT and STABILITY in...
https://www.fa.omron.co.jp/data_pdf/cat/e3z_photoelectric_operation_tg_e_7_3_csm442.pdf
...物体より高いか同程度の場合 ①a=30 +30 mmにセットしてください。 ②感度調整ボリウム(SENSITIVITY) を最大にし、アンプの入光(LIGHT) と安定レベル (STABILITY)表示が点灯することを確認してくださ...
https://www.fa.omron.co.jp/data_pdf/cat/e3z_photoelectric_operation_tg_j_7_3.pdf
...paquing: Polarization-opaquing (Refer to page 9 for a technical description.) Patented Relative light reception (%) The E3ZM-B more than triples conventional detection performance, with outst...
https://www.fa.omron.co.jp/data_pdf/cat/e3zm-b_ds_e_4_10_csm2160.pdf