PDFソリッドステート・タイマ H3CR-G8EL AC100-120

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8EL_AC100-120/en/pdf/

PDFソリッドステート・タイマ H3CR-G8EL AC200-240

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8EL_AC200-240/en/pdf/

PDFソリッドステート・タイマ H3CR-G8L-30 AC100-120

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8L-30_AC100-120/en/pdf/

PDFソリッドステート・タイマ H3CR-G8L-30 AC200-240

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8L-30_AC200-240/en/pdf/

PDFソリッドステート・タイマ H3CR-G8L AC100-120

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8L_AC100-120/en/pdf/

PDFソリッドステート・タイマ H3CR-G8L AC200-240

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-G8L_AC200-240/en/pdf/

PDFソリッドステート・タイマ H3CR-H8L AC100-120 M

...s) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-H8L_AC100-120_M/en/pdf/

PDFソリッドステート・タイマ H3CR-H8L AC100-120 S

...s) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-H8L_AC100-120_S/en/pdf/

PDFソリッドステート・タイマ H3CR-H8L AC/DC24 M

...s) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-H8L_AC_DC24_M/en/pdf/

PDFソリッドステート・タイマ H3CR-H8L AC/DC24 S

...s) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 8 kV, Destruction: 15 kV Vibration re...

https://www.fa.omron.co.jp/product/item/H3CR-H8L_AC_DC24_S/en/pdf/

PDFソリッドステート・タイマ H3DK-F AC/DC24-240

...metal parts: 5 kV Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-F_AC_DC24-240/en/pdf/

PDFソリッドステート・タイマ H3DK-G AC/DC24-240

...metal parts: 5 kV Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-G_AC_DC24-240/en/pdf/

PDFソリッドステート・タイマ H3DK-HBL AC/DC24-48

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HBL_AC_DC24-48/en/pdf/

PDFソリッドステート・タイマ H3DK-HBS AC/DC24-48

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HBS_AC_DC24-48/en/pdf/

PDFソリッドステート・タイマ H3DK-HCL AC100-120V

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HCL_AC100-120V/en/pdf/

PDFソリッドステート・タイマ H3DK-HCS AC100-120V

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HCS_AC100-120V/en/pdf/

PDFソリッドステート・タイマ H3DK-HDL AC200-240V

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HDL_AC200-240V/en/pdf/

PDFソリッドステート・タイマ H3DK-HDS AC200-240V

...unity ±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV Vibration res...

https://www.fa.omron.co.jp/product/item/H3DK-HDS_AC200-240V/en/pdf/

PDFソリッドステート・タイマ H3DK-M1 AC/DC24-240

...metal parts: 5 kV Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV 03 ソリッドス...

https://www.fa.omron.co.jp/product/item/H3DK-M1_AC_DC24-240/en/pdf/

PDFソリッドステート・タイマ H3DK-M2 AC/DC24-240

...metal parts: 5 kV Noise immunity ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) Static immunity Mulfunction: 4 kV, Destruction: 8 kV 03 ソリッドス...

https://www.fa.omron.co.jp/product/item/H3DK-M2_AC_DC24-240/en/pdf/