| Site Search | Product Search | IA Global Search |
...d in programming for the NJ/NX/NY Controller. There is no need to change internal addresses and timer numbers. This means that the preventive maintenance function can be added easily. ·The ti...
https://www.omron.com.tw/data_pdf/cat/device_operation_monitor_library_p101-e1_2_3_csm1047446.pdf
...(2) mm 1.5 (3) mm 2 (5) mm 5 (10) mm 10 (18) mm Unshielded 20 (50) mm * Self-diagnostic output, timer, and DIN Track mounting. Amplifier Units Model Power supply/ Output Timer func- ...
https://www.omron.com.tw/data_pdf/cat/e2c_e2c-h_ds_e_9_6_csm445.pdf
...ctor (26.4 VDC max.), load current: 100 mA max., residual voltage: 1 V max. Functions OFF-delay timer 0 to 40 ms (1 to 20 ms: 1-ms increments, 20 to 40 ms: 5-ms increments) Zero reset Support...
https://www.omron.com.tw/data_pdf/cat/e2cy-sd_d112-e1_3_1_csm1000536.pdf
...ng between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-...
https://www.omron.com.tw/data_pdf/cat/e2e-_-il__ds_e_1_2_csm1071692.pdf
...ng between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-...
https://www.omron.com.tw/data_pdf/cat/e2eq-_-il__ds_e_1_2_csm1071693.pdf
...ple distance model) DC 3-wire *1. The response frequency is an average value. Factory setting: (timer function: ONOFF delay) *2. IO-Link is not supported for NC-type PNP outputs or all types ...
https://www.omron.com.tw/data_pdf/cat/e2ew_d122-e1_7_2_csm1072894.pdf
...lected for detection function. Functions Operation mode NO (Normally Open)/NC (Normally closed) Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-del...
https://www.omron.com.tw/data_pdf/cat/e2nc_e473-e1_7_1_csm1061200.pdf
...or output E3X-DA41TG-S Item Power supply voltage Power consumption Control output Response time Timer function 12 to 24 VDC±10%, ripple (p-p) 10% max. 960 mW max. (current consumption: 40 mA ...
https://www.omron.com.tw/data_pdf/cat/e32-l11_e392-e1_1_1_csm1065349.pdf
...or Functions Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-del...
https://www.omron.com.tw/data_pdf/cat/e32_e3nx-fa_e3nw_e418-e1_20_6_csm1002396.pdf
... and NC, execution of teaching (2-point teaching, Background teaching), setup of the threshold, timer function of the control output and timer time selecting, Restore Factory Setting...
https://www.omron.com.tw/data_pdf/cat/e3as-hl_f_l_e594-e1_4_7_csm1105100.pdf
... and NC, execution of teaching (2-point teaching, Background teaching), setup of the threshold, timer function of the control output and timer time selecting, Restore Factory Setting...
https://www.omron.com.tw/data_pdf/cat/e3as-hl_f_l_e595-e1_10_1_csm1105104.pdf
...) 10 Standard Mode (Stnd) 10 Giga Mode (GIGA) 10 Functions Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay or one-shot timer. 1 to...
https://www.omron.com.tw/data_pdf/cat/e3c-lda_n_e605-e1_1_3_csm1118673.pdf
... NPN open collector output type (residual voltage: 1 V max.) Light-ON/Dark-ON switch selectable Timer function OFF-delay 0/40 ms (switch selectable) Ambient temperature range Operating:−10°to...
https://www.omron.com.tw/data_pdf/cat/e3c_ds_e_11_5_csm418.pdf
...with the E3JM-R4@4(T), E3JM-R4@4(T)-G and E3JM-R4@4(T)-US Models. Red light Infrared light 10 m Timer Timer 4 m Timer Timer 700 mm Timer Timer E3J...
https://www.omron.com.tw/data_pdf/cat/e3jm_ds_e_12_9_csm421.pdf
...ਣႬᏣONȂ DCᒰяᜱϰӈON MODE 0 1 MODE 0 1 Τӏਣ ᎎӏਣ ON OFF ON OFF LΔON DΔON MODE 0 1 DΔON LΔON SW1 SW2 TIMER ձዂԓ Ϲඳᜱ ۢਣᏣዂԓ Ϲඳᜱ MODE 0 1 DΔON LΔON SW1 SW2 TIMER SW1ȃSW2ڎࣲȶ0ȷ MODE 0 1 DΔO...
... Standard mode (Stnd) 2 Giga-power mode (GIGA) 4 Functions Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-del...
https://www.omron.com.tw/data_pdf/cat/e3nc_ds_e_9_6_csm1018967.pdf
...or Functions Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-del...
https://www.omron.com.tw/data_pdf/cat/e3nx-fa_ds_e_16_8_csm1010440.pdf
...) 10 Giga-power mode (GIGA) 10 Functions Auto power control (APC), dynamic power control (DPC), timer, zero reset, resetting settings, eco mode, bank switching, power tuning, and hysteresis w...
https://www.omron.com.tw/data_pdf/cat/e3nx-fa_e426-e1_10_4_csm1010499.pdf
... set to super-high-speed mode. Functions Auto power control (APC), dynamic power control (DPC), timer, zero reset, resetting settings, eco mode, bank switching, power tuning, and hysteresis w...
https://www.omron.com.tw/data_pdf/cat/e3nx-ma_e466-e1_1_4_csm1060634.pdf
...it Functions Automatic power control (APC) Always enabled. Dynamic power control (DPC) Provided Timer Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay + OFF-del...
https://www.omron.com.tw/data_pdf/cat/e3nx-ma_e467-e1_1_7_csm1060689.pdf