Primary Contents

IA Global Search Results

Select Country in

Site Search Product Search IA Global Search
Results 1181 - 1200 of 1243
PDF样本编号:W473-CN5-09 SYSMAC CJ系列 CJ2H-CPU6□-EIP

...口,可方便地连接条形码识别机等通用设备及PT、CJ/CP系列PLC及变频器等其它设备。 可加装串行选件卡(仅限CJ2M-CPU3@) $0.. RDA- RDB+ SDA- SDB+ FG $0.. RDA- RDB+ SDA- SDB+ FG $0.. 34$ $+.$16ƾ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/w473-cn5-09_discon.pdf

PDFCat. No. Z042-E1-4 Multipoint Temperature Controll...

... RS-422: SG Not used. 23 SDA, (–) RS-422: SDA, RS-485: (–) SDB, (+) RS-422: SDB, RS-485: (+) 24 RDA RS-422: RDA RDB RS-422: RDB 25 and 26 Not used. Not used. 27 CT0 Point 0 CT input ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z042-e1-04_e5zd.pdf

PDFCat. No. Z87-E1-1 FA ID System V630

...ode: 72 = Data Carrier missing) is returned. Point to Point (1:1) Communications Command Format RDA/H1XXXX∗ Header ASCII/HEX code specification A: ASCII code, JIS 8 code H: HEX code R/W Head ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z087-e1-01_v630.pdf

PDFCat. No. Z122-E1-01A Hand-held Reader Writer

...mand for details.) ASCII/hexadecimal code setting A: ASCII code, JIS 8 code H: Hexadecimal code RDA/H1XXXXXX∗ Header Processing area number setting Start address No. setting Read Response For...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z122-e1-01a_v600-ch1d.pdf

PDFCat. No. Z144-E1-04 F160 Vision Sensor

...l Name 1 FG Protective frame ground 2SDFor RS-232C 3RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7SDB(+) 8SDA(-) 9 GND Signal ground Model Model No. Plug XM2A-0901 Hood XM2S-0911 1 2 3 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z144-e1-04_f160.pdf

PDFCat. No. Z155-E1-02 2-Dimensional Code Reader

...SD (TXD) RD (RXD) RS (RTS) CS (CTS) +5 V SG (GND) NT-AL001 NT-AL001 Signal SG (GND) SDB SDA RDB RDA Pin No. 23 45 6 Pin No. 23 45 6 Signal SG (GND) SDB SDA RDB RDA NT-AL001 on host s...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z155-e1-02_v530-r150e-3_r150ep-3.pdf

PDFCat. No. Z170-E1-02E F160-2 Vision Sensor

...Name 1 FG Protective frame ground 2 SD For RS-232C 3RD 4 NC Not connected 5 RDB(+) For RS-422 6 RDA(-) 7SDB(+) 8SDA(-) 9 GND Signal ground Model Model No. Plug XM2A-0901 Hood XM2S-0911 1 2 3 ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z170-e1-02e_f160-2.pdf

PDFRFID System V600 Series User's Manual

...Connecting to the Host Device ■RS-422 Connection The +/−polarity designations for the SDA, SDB, RDA, and RDB signals are reversed on some devices. Always check the signal names of the connect...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z239-e1-04_v600-ca5d0_.pdf

PDFS8M Digital Multicircuit Protector

...C1 123456 123456789 PWR NC SG PWR SD RD 123456 123 PWR NC SG PWR SD RD SD RD SG 789 10 11 12 SG RDA(-) SDA(-) NC RDB(+) SDB(+) 789 10 11 12 SG RDA(-) SDA(-) NC RDB(+) SDB(+) Computer...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z241-e1-03_s8m.pdf

PDFSetup manual Fiber Laser Marker

...on the external device. 8(Not used) RS-422A 9 RDB (+) Enters data from the external device. 10 RDA () Enters data from the external device. 11 SDB (+) Outputs data from the controller. 12 S...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z376-e1-06_mx-z2000h.pdf

PDFUser’s manual Fiber Laser Marker

...on the external device. 8(Not used) RS-422A 9 RDB () Enters data from the external device. 10 RDA () Enters data from the external device. 11 SDB (Outputs data from the controller. 12 SD...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z377-e1-06_mx-z2000h.pdf

PDFCJ Series General-purpose Serial

...nit applicable connector: Terminal block Pin No. Symbol Signal name Input/Output 1(See note 1.) RDA Receive data - Input 2(See Note 1.) RDB Receive data + Input 3(See Note 1.) SDA Send data -...

https://www.omron-ap.com/data_pdf/closed/mnu/p641-e1-01_3g3mx2-v1.pdf

PDFCJ Series General-purpose Serial

...nit applicable connector: Terminal block Pin No. Symbol Signal name Input/Output 1(See note 1.) RDA Receive data - Input 2(See Note 1.) RDB Receive data + Input 3(See Note 1.) SDA Send data -...

https://www.omron.com.tw/data_pdf/closed/mnu/p641-e1-01_3g3mx2-v1.pdf

PDFRFIDシステム 形V630シリーズ 生産終了のお知らせ

...SDA − ○ 9 送信データB SD− − ○ 送信データB (SD+) SDB − ○ 5 受信データA RD+ ○ − 受信データA (RD−) RDA ○ − 6 受信データB RD− ○ − 受信データB (RD+) RDB ○ − 1 ピン配列(はんだ付け側より見...

https://www.fa.omron.co.jp/data_pdf/closed/2001115.pdf

PDFファジィ温度調節器 基本タイプ 形E5AF 生産終了のお知らせ

...温体の場合 15 ( 14 の短絡片は、 付けたままにして + おきます) 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB ヒータ断線警報付の場合 通信用コネクタ (通信機能付の場合、 図はRS232...

https://www.fa.omron.co.jp/data_pdf/closed/2001116.pdf

PDFデジタル指示温度調節器 電流電圧入力タイプ 形E5AX-LA/-MA 生産終了のお知らせ

...1∼5V、0∼5V、 0∼1Vの場合 + − 4∼20mA、 0∼20mAの場合 + コネクタ 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB 形E5AX-MAの場合 14 13 12 11 − 0∼100mVの場合 + − B(+) A(−) SG A...

https://www.fa.omron.co.jp/data_pdf/closed/2001118.pdf

PDFデジタル指示温度調節器 コントロールバルブ制御タイプ 形E5AX-PRR 生産終了のお知らせ

...まにして + おきます) 14 4 13 3 12 2 11 1 4∼20mA伝送出力 B 15 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) B(+) A(−) SG A...

https://www.fa.omron.co.jp/data_pdf/closed/2001119.pdf

PDFデジタル指示温度調節器 加熱冷却出力タイプ 形E5AX-VA 生産終了のお知らせ

...熱電対測温体の場合 (⑭⑮の短絡片は、 付けたままにして + おきます) 4∼20mA伝送出力 通信端子部 RS-422 RS-485 RDB RDA SG SDA SDB 通信用コネクタ (通信機能付の場合、 図はRS232C、BCDの場合です) B...

https://www.fa.omron.co.jp/data_pdf/closed/2001120.pdf

PDFファジィ温度調節器 基本タイプ 形E5EF 生産終了のお知らせ

...8 − − 電流ユニットを入れた場合 + 10 7 6 5 B(+)3 RS-485 A(−) 2 SG RS-422 1 SDA 4 RDB 3 RDA 2 SG 1 FG 17 16 AC100∼240V 50/60Hz 15 14 SDB RS-422 13 12 B 12 11 11 10 10 − + B 11 10 A 熱電...

https://www.fa.omron.co.jp/data_pdf/closed/2001121.pdf

PDFデジタル指示温度調節器 基本タイプ 形E5EX 生産終了のお知らせ

...SG 熱電対測温体の場合 13 14 の短絡片は、 ( + 付けたままにしておきます) 6 RS-422 1 SDA 4 RDB 3 RDA 2 SG 1 16 AC100∼240V 50/60Hz 15 14 SDB RS-422 13 12 B 12 11 11 10 10 − + B 11 10 A 熱電対...

https://www.fa.omron.co.jp/data_pdf/closed/2001123.pdf

Results 1181 - 1200 of 1243

Select Country in