PDF[Z259-E1-03] ZR-RX40 Portable Multi Logger Start U...

...) Measurement Accuracy 0 ≤TS ≤100 ±5.2 ° C 100 < TS ≤300 ±3.0 ° C R: 300 < TS ≤1600 ±(0.05 % of rdg +2.0 ° C) S: 300 < TS ≤1760 ±(0.05 % of rdg...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z259-e1-03_zr-rx40.pdf

PDF[Z260-E1-04] ZR-RX40 Portable Multi Logger User's ...

...surement Accuracy 0 ≤ TS ≤ 100 ± 5.2 °C 100 < TS ≤ 300 ± 3.0 °C R: 300 < TS ≤ 1600 ± (0.05 % of rdg +2.0 °C) S: 300 < TS ≤ 1760 ± (0.05 % of rdg...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z260-e1-04_zr-rx40.pdf

PDF[Z283-E1-03] ZR-RX70 Portable Multi Logger User's ...

...urement accuracy R/S 0 ≤ TS ≤ 100 ± 7.0°C 100 < TS ≤ 300 ± 5.0°C R: 300 < TS ≤ 1600 ± (0.05% of rdg + 3.0°C) S: 300 < TS ≤ 1760 ± (0.05% of rdg...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z283-e1-03_zr-rx70.pdf

PDF[Z303-E1-02] ZR-RX25 Data Logger User's Manual

...R/S 0 ≤ TS ≤ 100 100 < TS ≤ 300 R: 300 < TS ≤ 1600 S: 300 < TS ≤ 1760 ±5.2°C ±3.0°C ±(0.05 % of rdg +2.0°C) ±(0.05 % of rdg +2.0°C) B 400 ≤ TS ≤ 600 600 < TS ≤ 1820 ±3.5°C ±(0.05 % o...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z303-e1-02_zr-rx25.pdf

PDF[Z304-E1-03] ZR-RX45 Data Logger User's Manual

...R/S 0 ≤ TS ≤ 100 100 < TS ≤ 300 R: 300 < TS ≤ 1600 S: 300 < TS ≤ 1760 ±5.2°C ±3.0°C ±(0.05 % of rdg +2.0°C) ±(0.05 % of rdg +2.0°C) B 400 ≤ TS ≤ 600 600 < TS ≤ 1820 ±3.5°C ±(0.05 % o...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/z304-e1-03_zr-rx45.pdf

PDF[3733662-3B] ZN-DCC11 DCクランプロガー 取扱説明書

...ない箇所に取り付けてご使用ください。 定格測定電流 DC ±200A 許容測定電流 定格測定電流の110% 0∼±24.9A ±2.0%rdg±5digit ±25.0∼±99.9A ±2.5%rdg±5digit ±100∼±200A ±2.0%rdg±1digit ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/zn-dcc11_inst-3733662-3b.pdf

PDFCSM_ES1_DS_C_3_3 1 400-820-4535 www.fa.omron.com.c...

...% 消耗电流40mA以下(但连接编程器时为45mA以下) 电缆长度2m±10cm 测量精度 ±(2+0.1%输出范围)℃以内 (测量温度0~+200℃) ±(1%rdg+0.1%输出范围)℃以内 (+200~+1,000℃) (环境温度23℃、湿度55...

https://www.fa.omron.com.cn/data_pdf/closed/cat/es1_ds_c_3_3.pdf

PDFCSM_K3TE_DS_C_3_1 1 400-820-4535 www.fa.omron.com....

...本体外壳:IP20 端子部:IP00 测量范围最高分辨率输入阻抗测量精度(23±5℃)最大容许输入(连续) 直流电压 ±199.9mV 100μV 100MΩ±0.1%rdg±1位数±250V ±1.999V 1mV 100MΩ±0.1%rdg±1位数±250V ±1...

https://www.fa.omron.com.cn/data_pdf/closed/cat/k3te_ds_c_3_1_discon.pdf

PDFCSM_K3TE_DS_E_3_1 1 Digital Panel Meter

... resolution Input impedance Accuracy Max. permissible load DC voltage±199.9 mV 100µV 100 MΩ±0.1%rdg±1 digit±250 V ±1.999 V 1 mV 100 MΩ±0.1%rdg±1 digit±250 V ±19.99 V 10 mV 10 MΩ±0.1%...

https://www.fa.omron.com.cn/data_pdf/closed/cat/k3te_ds_e_3_1_csm256.pdf

PDFCSM_K3TF_DS_C_4_1 1 400-820-4535 www.fa.omron.com....

...端子部:IP00 测量范围最高分辨率输入阻抗测量精度(23±5℃)最大容许输入(连续) 线性监控器交流电压 0~199.9V 100mV 10MΩ±0.3%rdg±1位数* 500V 0~400V 1V 10MΩ±0.3%rdg±1位数500V 信号监控...

https://www.fa.omron.com.cn/data_pdf/closed/cat/k3tf_ds_c_4_1_discon.pdf

PDF1 CSM_K3TF_DS_E_4_1 Digital Panel Meter

... impedance Accuracy Max. permissible load Line monitor AC voltage 0 to 199.9 V 100 mV 10 MΩ±0.3%rdg±1 digit (see note 1) 500 V 0 to 400 V 1 V 10 MΩ±0.3%rdg±1 digit 500 V Signal monit...

https://www.fa.omron.com.cn/data_pdf/closed/cat/k3tf_ds_e_4_1_csm257.pdf

PDF1 CSM_K3TG_DS_E_2_1 Digital Panel Meter

... resolution Input impedance Accuracy Max. permissible load DC voltage±199.9 mV 100µV 100 MΩ±0.1%rdg±1 digit±250 V ±1.999 V 1 mV 100 MΩ±0.1%rdg±1 digit±250 V ±19.99 V 10 mV 10 MΩ±0.1%...

https://www.fa.omron.com.cn/data_pdf/closed/cat/k3tg_dsheet_csm258.pdf

PDFCSM_S8M_CA_C_2_4 1 400-820-4535 www.fa.omron.com.c...

...电极开路输出 DC30V max. 50mA max.、漏电流0.1mA以下、残留电压2V以下显示功能输入电压显示显示范围:17.0~30.0V 显示精度:2%rdg±1位以下输出电流显示分支输出显示范围:0.0~4.0A 峰值电流显示范围:0...

https://www.fa.omron.com.cn/data_pdf/closed/cat/s8m_ca_c_2_4_discon.pdf

PDF1 Digital Multicircuit Protector S8M

...dual voltage: 2 V max. Display Input voltage Display range: 17.0 to 30.0 V Display accuracy: 2% rdg±1 digit max. Output current Branch output display range: 0.0 to 4.0 A Peak output current d...

https://www.fa.omron.com.cn/data_pdf/closed/cat/s8m_t232-e1_3_4_csm2006.pdf

PDF取扱説明書 オムロン製品をお買いあげいただきありがとう ございます。

...確度 V1 DC±199.9mV DC±1.999V DC±19.99V DC±199.9V DC±199.9μA DC±1.999mA DC±19.99mA DC±199.9mA ±0.1%rdg±1ディジット ±0.1%rdg±1ディジット ±0.1%rdg±1ディジット ±0.1%rdg...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/k3te_inst-2381913-3d.pdf

PDF取扱説明書 オムロン製品をお買いあげいただきありがとう ございます。

...なります。 安全上要点 ■仕様 ●確度コード計測範囲確度 V5 V6 V7 V8 V9 A6 A7 A8 A9 0~199.9mV AC±0.3%rdg±1ディジット 0~1.999 V AC±0.3%rdg±1ディジット 0~19.99 V AC±0.3%rdg±1デ...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/k3tf_inst-2381914-1f.pdf

PDFCat. No. N093-E1-1A Frequency/Rate Meter

...urrence of an error can be obtained. Performance Characteristics Accuracy of measurement±0.006% rdg±1 digit (ambient temperature: 23°C±5°C) Measurement range Sensor with transistor output: 0....

https://www.fa.omron.com.cn/data_pdf/closed/mnu/n093-e1-01a_k3nr.pdf

PDFい!、1一叶〆~川ttXllll、 可摘程序控制器 CQMIH系列

...× 01 }{ 1b2 X 1 03 X 000102030405 } … 012345678910刊 1213141516 1 愉人数据麓□ 闇一数D 位字 4用 ※使只ほ当吋 1」 信爲 RDG妻)信号 1千柁次あ」、志 16↑循跡先成介暑丸有給次座用例当DSW(87)執行flj'IR...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/oez-zdp00101a_cqm1h_discon.pdf

PDFS8M Digital Multicircuit Protector

... func- tions Input voltage display/ detection Display range:17.0 to 30.0 V Display accuracy: 2% rdg±1 digit max. Output current display/ detection Branch output display range: 0.0 to 10.0 A P...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z241-e1-03_s8m.pdf

PDFStart Up Guide Portable Multi Logger

...nge (°C) Measurement Accuracy R/S 0≤TS≤100±5.2°C 100 < TS≤300±3.0°C R: 300 < TS≤1600±(0.05 % of rdg +2.0°C) S: 300 < TS≤1760±(0.05 % of rdg +2.0°C) B 400≤TS≤600±3.5°C 600 < TS≤1820±(...

https://www.fa.omron.com.cn/data_pdf/closed/mnu/z259-e1-03_zr-rx40.pdf