Site Search | Product Search | IA Global Search |
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...
...urrent consumption 12 mA (L terminal open) Control output Output type NPN open collector output Load power supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 ...
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...
...urrent consumption 12 mA (L terminal open) Control output Output type NPN open collector output Load power supply voltage 5 to 24 VDC Load curren 100 mA max. Residual voltage at 100 ...
...urrent consumption 12 mA (L terminal open) Control output Output type PNP open collector output Load power supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA...
... 9.1 mA 110 VDC 10 mA Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...il surge killer Diode Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
... 240 VAC 60 Hz 4.6 mA Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...DC 16 mA Contact form DPDT Contact method Single Contact material Au plating + Ag Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ = 0.4))...
...DC 50 mA Contact form DPDT Contact method Single Contact material Au plating + Ag Contact rated load 220 VAC 3 A (Resistive load) 220 VAC 0.8 A (Inductive load (cosφ = 0.4))...
...erating indicator LED Contact form DPDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...mA 12 VAC 60 Hz 91 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
... 240 VAC 60 Hz 4.6 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...atings 48 VDC 18.5 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
... 120 VAC 60 Hz 9.2 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...mA 12 VAC 60 Hz 91 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
... 220 VAC 60 Hz 5.8 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
... 220 VAC 60 Hz 5.8 mA Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...erating indicator LED Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...
...erating indicator LED Contact form 3PDT Contact method Single Contact material Ag Contact rated load 220 VAC 5 A (Resistive load) 220 VAC 2 A (Inductive load (cosφ = 0.4)) 2...