Site Search | Product Search | IA Global Search |
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron-ap.com/data_pdf/mnu/g3pf_inst-1278628-4b_en.pdf
...tput range: 4 to 20 mA DC 0 to 20 mA DC Allowable load impedance: 350 Ω max. (See note.) Note A G32A-EA Cycle Control Unit (made by OMRON; internal load impedance: 352 Ω) can be used. • The p...
...ssible at a control cycle of 200 ms min. and an output duty of 50% min. (When combined with the G32A-EA, heater burnout can be detected at an output duty of 50% or higher.) 4. When using cycl...
https://www.omron.co.id/data_pdf/cat/g3pf_ds_e_7_11_csm748.pdf
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.co.id/data_pdf/mnu/g3pf-ctb_-stb_inst-2798050-8b_en.pdf
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.co.id/data_pdf/mnu/g3pf_inst-1278628-4b_en.pdf
...ssible at a control cycle of 200 ms min. and an output duty of 50% min. (When combined with the G32A-EA, heater burnout can be detected at an output duty of 50% or higher.) 4. When using cycl...
https://www.omron.com.au/data_pdf/cat/g3pf_ds_e_7_11_csm748.pdf
...CSM_G32A-EA_DS_E_7_3 1 Cycle Control Units G32A-EA Refer to Safety Precautions for All Power Controllers. Used in Combination with the G3PA to Enable High-precision Temperature Contr...
https://www.omron.com.tw/data_pdf/cat/g32a-ea_ds_e_7_3_csm182.pdf
...CSM_G32A-EA_DS_TW_7_3 1 循環控制模組G32A-EA 與SSR組合後可進行高精度溫度控制模組 •採用循環控制方式可進行雜訊較少的電力控制。 •若與SSR組合,單相負載與三相負載皆可使用。 •可選擇內部設定...
...ssible at a control cycle of 200 ms min. and an output duty of 50% min. (When combined with the G32A-EA, heater burnout can be detected at an output duty of 50% or higher.) 4. When using cycl...
https://www.omron.com.tw/data_pdf/cat/g3pf_ds_e_7_11_csm748.pdf
...電流範圍,設定加熱器斷線檢測電流。 註3.如為循環控制,控制週期200ms且輸出工作負載50%以上時可進行斷線檢測。 (若與G32A-EA型組合使用,輸出工作負載50%以上時可進行斷線檢測。 ) 註4.如為循環控制...
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.com.tw/data_pdf/mnu/g3pf-ctb_-stb_inst-2798050-8b_en.pdf
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.com.tw/data_pdf/mnu/g3pf_inst-1278628-4b_en.pdf
... control output 2 (OUT2). •The following table shows the specifications for each output. Note A G32A-EA Cycle Control Unit (made by OMRON; internal load impedance: 352Ω) can be used. •The pul...
...ssible at a control cycle of 200 ms min. and an output duty of 50% min. (When combined with the G32A-EA, heater burnout can be detected at an output duty of 50% or higher.) 4. When using cycl...
https://www.omron.com.vn/data_pdf/cat/g3pf_ds_e_7_11_csm748.pdf
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.com.vn/data_pdf/mnu/g3pf-ctb_-stb_inst-2798050-8b_en.pdf
...eater burnout detection is possible with a control cycle of 200ms min. and duty of 50% min. The G32A-EA can be used under these conditions. NOTE:4. When using cycle control, the detection tim...
https://www.omron.com.vn/data_pdf/mnu/g3pf_inst-1278628-4b_en.pdf
...期」が 0.2s ∼ 99.0s で設定できます。 (当社、従来品は 1s からの設定) よって、従来当社サイクルコントロールユニット(形 G32A-EA)と SSR との組合わせで、高精度な温度制御を実施していたアプリケー...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/sgtd-722b-11_e5ar_e5er.pdf
...ision control applications that previously required the combined use of our cycle control unit (G32A-EA) and an SSR, the G32A-EA is now no longer needed. The platinum resistance temp...
https://www.fa.omron.co.jp/data_pdf/closed/mnu/z182-e1-04_e5ar_e5er.pdf
...f a few sec- onds over a period of several years, then an SSR must be used. With cycle control (G32A-EA), output voltage is turned ON/OFF at a fixed interval of 0.2 s. Control is performed in...
https://www.omron.com.tw/data_pdf/closed/mnu/y108-01_solid_state_relays.pdf
... Transistor Output Unit (pulse output) • Position Control G3PW Power Controller • Cycle Control G32A-EA + G3PA • SSR G3PA/B/C, G3NA, etc. CJ1W-OC Relay Output Unit • ON/OFF Control RS-485 com...
https://www.fa.omron.co.jp/data_pdf/closed/cat/cj1g-cpu__p_r128-e1_12_15_csm1004121.pdf