| Site Search | Product Search | IA Global Search |
...K +9 0000 0000 0000 0000 +8 0000 0000 0000 0001 Response code (32-bit) Command execution result NG (no corresponding command) +9 1111 1111 1111 1111 +8 0000 0000 0000 0010 Response code (32-b...
https://www.fa.omron.com.cn/data_pdf/mnu/z363-e1-07_zw-_000.pdf
... image input from a Camera, measurement processing, and output of measurement results (e.g., OK/NG judge- ment results) are executed in the order that those processing items are registered in...
...range 0 Judge Get only 0: No judgement (unmeasured) 1: Judgement result OK -1: Judgement result NG 5 + N x 1 (N = 0 to 31) Calculation result N (N = 0 to 31) Set/Get -99999.9999 to 99999.9999...
...- Read Cycle - Trigger - Mode - External Edge or Serial Data and Edge. How can I confirm the OK/NG Read result over Ether- Net/IP? The method differs according to the selected input assembly....
https://www.fa.omron.com.cn/data_pdf/mnu/z392-e1-08_v430-f.pdf
...Control panel Control panel High-voltage power panel Safety I/O terminal Safety I/O terminal OK NG Example of Arrangement in Panel AC I/O device Terminal block DC I/O device Safety I/O termin...
https://www.fa.omron.com.cn/data_pdf/mnu/z400-e1-09_gi-s.pdf
...followed by
https://www.fa.omron.com.cn/data_pdf/mnu/z402-e1-11_v780-hmd68-e__-__.pdf
...the entered condition (No. 5). The result is displayed in area 4. If the result is Installation NG, review the entered condition above. 6-5 Click [Close] button (No. 7). For more information ...
https://www.fa.omron.com.cn/data_pdf/mnu/z405-e1-08_f3sg-sr_pg.pdf
...g types of system configurations. Connection using Parallel I/O Interface Trigger inputs and OK/NG Judgement result outputs are received and sent over I/O cable. *1 If monitor display is not ...
https://www.fa.omron.com.cn/data_pdf/mnu/z407-e1-06_v3_0-f_v4_0-f.pdf
... image input from a Camera, measurement processing, and output of measurement results (e.g., OK/NG judge- ment results) are executed in the order that those processing items are registered in...
https://www.fa.omron.com.cn/data_pdf/mnu/z408-e1-11_fhv7h.pdf
...nd output character strings of the code reader, such as Accept Trigger confirmation and Read OK/NG results. ■Definition of Input Area access data types (structure) Data types for accessing th...
https://www.fa.omron.com.cn/data_pdf/mnu/z411-e1-02_v330-f_v430-f.pdf
...nd output character strings of the code reader, such as Accept Trigger confirmation and Read OK/NG results. ■Definition of Input Area access data types (structure) Data types for accessing th...
https://www.fa.omron.com.cn/data_pdf/mnu/z420-e1-02_v330-f_v430-f.pdf
...estination settings) ........................ 158 Analyzing inspection and measurement results (NG analyzer) ............................................................. 160 Layout of ...
...tus signals, refer to Control with Control Signals and Status Signals (p.22). Overall judgement NG is output whenever there is one or more NGs in the judgement results for multiple processing...
... image input from a Camera, measurement processing, and output of measurement results (e.g., OK/NG judgement results) are executed in the order that those processing items are registered in t...
...range 0 Judge Get only 0: No judgement (unmeasured) 1: Judgement result OK -1: Judgement result NG 5 + N×1 (N = 0 to 31) Calculation result N (N = 0 to 31) Set/Get -99999.9999 to 99999.9999 3...
...- Read Cycle - Trigger - Mode - External Edge or Serial Data and Edge. How can I confirm the OK/NG Read result over EtherNet/IP? The method differs according to the selected input assembly. •...
https://www.fa.omron.com.cn/data_pdf/mnu/z432-e-06 (84-9000400-02-e)_v3_0-f_v4_0-f.pdf
... image input from a Camera, measurement processing, and output of measurement results (e.g., OK/NG judge- ment results) are executed in the order that those processing items are registered in...
...timer in project file] Process Monitoring content Variable name Timeout (Default) Open Processi ng Time from start to end of Open processing TopenTime After 5 seconds (UINT#500) Send processi...
https://www.fa.omron.com.cn/data_pdf/mnu/z443-e-01_f430-f.pdf
...g types of system configurations. Connection using Parallel I/O Interface Trigger inputs and OK/NG Judgement result outputs are received and sent over I/O cable. *1 If monitor display is not ...
https://www.fa.omron.com.cn/data_pdf/mnu/z444-e-05_f4_0-f.pdf
... it is not calibrated, Not complied is displayed. If the warmup is incomplete, the judgement is NG •Checked •[Unchecked] If checked, the judgment result for this processing item is ...
https://www.fa.omron.com.cn/data_pdf/mnu/z445-e1-03_fh-505__smda-gs050b.pdf