| Site Search | Product Search | IA Global Search |
... ETRIG setting is ELPSD ELPSD CT Powr rate/ CO2 emission c onversion value VOLT Conversion unit PF Ranking (2) For AC adapter, connect the AC plug into an outlet (100 VAC to 240 VAC). For DC ...
https://www.omron-ap.co.nz/data_pdf/mnu/zn-ctx21-__inst-3730498-5h.pdf
...outlet, Neutralization: From ±1000 V down to ±100 V with Charge Plate monitor (150 x 150 mm, 20 pF) Temperature: 18℃ to 28℃ Humidity: 35% to 55% The performance might not be able to be satisf...
https://www.omron-ap.co.nz/data_pdf/mnu/zn-j25a_inst-9975456-1h.pdf
...outlet, Neutralization: From ±1000 V down to ±100 V with Charge Plate monitor (150 x 150 mm, 20 pF) Temperature: 18℃ to 28℃ Humidity: 35% to 55% The performance might not be able to be satisf...
https://www.omron-ap.co.nz/data_pdf/mnu/zn-j41a_inst-1835706-7g.pdf
... Dispose in accordance with applicable regulations. 1 910 Ω (a) Input/output connector 1,000 pF Thank you for selecting OMRON product. This sheet primarily describes precautions required i...
https://www.omron-ap.co.nz/data_pdf/mnu/zp-eip_inst-3687079-0c.pdf
...urrent Consumption 80 mA max. Weight 110 g max. Signal name 2.4 kΩ Internal circuits 560 Ω 1000 pF Jxx_Ch1_In00 COM0 Input indicator to Circuit Configuration 2.4 kΩ Internal circuits 560 Ω 10...
https://www.omron-ap.co.th/data_pdf/cat/cj1w-id_ia_ds_e_11_13_csm1616.pdf
...ultaneously ON points 3.3 kΩ Circuit Configuration Internal circuits Jxx_Ch1_In15 470 Ω to 1000 pF Jxx_Ch1_In00 COM COM Input indicator 16 10 8 6 4 2 0 Connector pin * External connection and...
https://www.omron-ap.co.th/data_pdf/cat/cj1w-idp01_ds_e_2_3_csm1614.pdf
...t 110 g max. Accessories None Signal name 3.3 kΩ COM Input indicator COM Internal circuits 1000 pF to Jxx_Ch1_In15 470 Ω Jxx_Ch1_In00 Circuit Configuration Number of simultaneously ON points ...
https://www.omron-ap.co.th/data_pdf/cat/cj1w-int01_ds_e_2_4_csm1615.pdf
...eously ON points Circuit Configuration 470 Ω Output indicator Wd m Connect or row A 3.3 kΩ 1000 pF Internal circuits Jxx_Ch1_Out00 to Jxx_Ch1_Out07 Signal name Jxx_Ch1_In00 to Wd m+1 Jxx_Ch1_...
https://www.omron-ap.co.th/data_pdf/cat/cj1w-md_ds_e_9_13_csm1618.pdf
...n Sockets that are certified for standards. 3 Common Sockets Round Sockets Model Number of pins PF (front-mounting), page 24 PF083A Approx. 34 g P2CF (front-mounting), page 25 P2CF-08 Approx....
https://www.omron-ap.co.th/data_pdf/cat/common_sockets_ds_e_6_10_csm1819.pdf
... max. 50 μs max. 1 ms max. IN Input LED 3.0 kΩ Internal circuits IN COM 910 Ω IN Input LED 1000 pF 4.3 kΩ 1000 pF Circuit configuration IN Input LED 3.0 kΩ Internal circuits IN COM 7...
https://www.omron-ap.co.th/data_pdf/cat/cp1h_p080-e1_11_13_csm1004100.pdf
...s max. 1 ms max. IN IN Input LED 3.0 kΩ Internal circuits IN COM 3.0 kΩ 910 Ω IN Input LED 1000 pF 4.3 kΩ 1000 pF Circuit configuration IN Input LED Internal circuits IN COM 4.7 kΩ 7...
https://www.omron-ap.co.th/data_pdf/cat/cp1l_p081-e1_10_12_csm1004101.pdf
...@ 11 51 Lock monitor D4JL-@QF@-@ Door open/ closed detection 2NC/1NO+2NC/1NO Lock monitor D4JL-@PF@-@ Door open/ closed detection 41-12 51-22 31-32 63-64 ON Stroke Operation Key insertion com...
https://www.omron-ap.co.th/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf
... Accuracy • Thermocouple/Pt input: ±0.1% of PV • Analog input: ±0.1% FS Sampling Period • 60 ms PF Key (Programmable key function) E5AN-H E5EN-H 3-level Display Simultaneously displays set it...
https://www.omron-ap.co.th/data_pdf/cat/e5an-h_e5en-h_ds_e_3_16_csm1377.pdf
...DC Voltage input Max. permissible capacitance between inputs lines (terminals B1 and A2): 2,000 pF Load connectable in parallel with inputs (terminals B1 and A1). H-level: 20.4 to 253 VAC/20....
https://www.omron-ap.co.th/data_pdf/cat/h3ds_ds_e_5_4_csm88.pdf
...lfunction. Therefore, when the input signal wiring is longer than 10 m (line capacitance of 120 pF/m, at room temperature), it is recommended that a CR filter or a bleeder resistor is connect...
https://www.omron-ap.co.th/data_pdf/cat/h7e_-n_ds_e_9_6_csm119.pdf
...arity 2 M swt2 Send Wait Time 2 M Active Power act M Ch1 to 3 R.M.S. Current Critical Threshold pf Ch1 R.M.S. Current Warning Threshold freq Power Factor M Power Frequency M Ch1 to 3 Current ...
https://www.omron-ap.co.th/data_pdf/cat/k7dd_n234-e1_3_3_csm1124083.pdf
...NX-series System Unit NX-PD/PF/PC/TBX CSM_NX-PD_PF_PC_TBX_DS_E_5_2 Power Supply Unit, Power Connection Unit, and FG Terminal Expansion Unit for NX-series Features • • • • • • • • Uni...
https://www.omron-ap.co.th/data_pdf/cat/nx-pd_pf_pc_tbx_ds_e_5_2_csm1012828.pdf
...32 NX Units can be connected. Safety CPU Unit NX-SL3@@@ NX-series NX102 CPU Unit System Unit NX-PF@@@@ Safety I/O Units NX-SI@@@@/ NX-SO@@@@ NX Units (32 Units max.) End Cover SD Memory Card ...
https://www.omron-ap.co.th/data_pdf/cat/nx-sl3____f109-e1_1_7_csm1105361.pdf
...to 32 NX Units can be connected. Safety CPU Unit NX-SL5 NX-series NX102 CPU Unit System Unit NX-PF Safety I/O Units NX-SI/ NX-SO NX Units (32 Units max.) End Cover SD Memory Card Built-in Eth...
https://www.omron-ap.co.th/data_pdf/cat/nx-sl5_f124-e1_5_1_csm1124265.pdf
... NX-series CPU Unit NX1P2- Support software (Sysmac Studio) Additional I/O Power Supply Unit NX-PF Unit power supply Heater Burnout Detection Unit NX-HB Temperature Input Unit NX-TS Connectio...
https://www.omron-ap.co.th/data_pdf/cat/nx-ts_hb_ds_e_4_2_csm1057423.pdf