| IAグローバル検索 |
... 10 Units max.; Total per PLC: 40 Units max. Basic I/O Units No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Special I/O Units Units for up to 96 unit numb...
https://www.omron-ap.com.my/products/family/2712/specification.html
... 10 Units max.; Total per PLC: 40 Units max. Basic I/O Units No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Special I/O Units Units for up to 96 unit numb...
https://www.omron-ap.com.ph/products/family/2712/specification.html
... 10 Units max.; Total per PLC: 40 Units max. Basic I/O Units No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Special I/O Units Units for up to 96 unit numb...
https://www.omron.co.id/products/family/2712/specification.html
... 10 Units max.; Total per PLC: 40 Units max. Basic I/O Units No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Special I/O Units Units for up to 96 unit numb...
https://www.omron.com.au/products/family/2712/specification.html
....1.0則為15μs) 可連接的模組數 每1台設備(CPU或增設) 10台。基本系統全部共40台。 基本I/O模組 無限制 但中斷輸入模組(CJ1W-INT01型)則最多為2台 高功能I/O模組 最多可安裝96號機份(號機No.0 ~ 95)的模組 ...
https://www.omron.com.tw/products/family/1993/specification.html
...編號:SDCA-005)。 更新日期 2024年4月26日 FA系統裝置 可程式控制器 CJ1 基本I/O模組 CJ1W-ID / IA CJ1W-OC / OA / OD CJ1W-MD CJ1W-INT01 CJ1W-IDP01 Top of page...
...15/Jxx_Ch4_In15 更新日期 2023年5月3日 FA系統裝置 可程式控制器 CJ1 基本I/O模組 CJ1W-ID / IA CJ1W-OC / OA / OD CJ1W-MD CJ1W-INT01 CJ1W-IDP01 Top of page...
https://www.omron.com.tw/products/family/2054/specification.html
...接頭纜線。 更新日期 2024年4月26日 FA系統裝置 可程式控制器 CJ1 基本I/O模組 CJ1W-ID / IA CJ1W-OC / OA / OD CJ1W-MD CJ1W-INT01 CJ1W-IDP01 Top of page...
...5/Jxx_Ch4_Out15 更新日期 2023年5月3日 FA系統裝置 可程式控制器 CJ1 基本I/O模組 CJ1W-ID / IA CJ1W-OC / OA / OD CJ1W-MD CJ1W-INT01 CJ1W-IDP01 Top of page...
https://www.omron.com.tw/products/family/2055/specification.html
... 10 Units max.; Total per PLC: 40 Units max. Basic I/O Units No limit However, a maximum of two CJ1W-INT01 Interrupt Input Units can be mounted. Special I/O Units Units for up to 96 unit numb...
https://www.omron.com.vn/products/family/2712/specification.html
...1 CJ1W-MD263 32 inputs, 32 outputs z TTL I/O Unit CJ1W-MD563 Other Units z Interrupt Input Unit CJ1W-INT01 --- --- z Quick-response Input Unit CJ1W-IDP01 z B7A Interface Units (64 inputs) CJ1...
https://www.fa.omron.co.jp/data_pdf/cat/cj2h_cj2m_p059-e1_17_27_csm1004123.pdf
...ニット形CJ1W-MD261 形CJ1W-MD263 (入力32点/出力32点) ●TTL入出力ユニット形CJ1W-MD563 その他のユニット ●割込入力ユニット形CJ1W-INT01 ―― ●パルスキャッチ入力ユニット形CJ1W-IDP01 ―― ●B7Aインタフ...
https://www.fa.omron.co.jp/data_pdf/cat/cj2h_cj2m_sbca-058_17_42.pdf
...on MSKS/CLI CS1G/H CJ2H CJ2M I/O Interrupts Operand (N) CS1W-INT01: 0 or 1 C200HS-INT01: 0 to 3 CJ1W-INT01: 0 or 1 *Review required when using multiple C200HS. CJ1W-INT01: 0 or 1 CJ2...
https://www.fa.omron.co.jp/data_pdf/mnu/p164-e1-03_cs1g_cs1h_cj2_replace.pdf
...-IA201 8 points Terminal block, 100 to 120 VAC, CJ1W-IA111 16 points Terminal block, 24 VDC, 16 CJ1W-INT01 points Terminal block, 24 VDC, 16 CJ1W-IDP01 points Yes Yes Yes Yes Yes Yes No Yes S...
https://www.fa.omron.co.jp/data_pdf/mnu/p172-e1-01_cs_cj_practice.pdf
...変化せず 変化せず P_N の動作 OFF 変化せず 変化せず I/O 割込み オペランド(N) CS1W-INT01:0~1 C200HS-INT01:0~3 CJ1W-INT01:0~1 ※C200HS 複数使用時は見直し必要 CJ1W-INT01:0~1 CJ2M ...
https://www.fa.omron.co.jp/data_pdf/mnu/sbca-141d_cs1g_cs1h_cj2_replace.pdf
...W-ID231 CS システムでの使用可否可可可可 CJ1W-ID232 CJ1W-ID233 CJ1W-ID261 可可可 CJ1W-ID262 CJ1W-IA201 CJ1W-IA111 CJ1W-INT01 CJ1W-IDP01 可可可不可可 仕様 形式 端子台 AC250V/DC24V 2A 8 点独立接...
https://www.fa.omron.co.jp/data_pdf/mnu/sbca-147a_cs_cj_practice.pdf
...5月 推奨代替品は生産終了 割込入力ユニット C200HS-INT01 2017年3月 生産終了 生産終了案内 割込入力ユニット CJ1W-INT01 現行商品 割込入力ユニット CS1W-INT01 現行商品 1 2 次へ 関連情報...
https://www.fa.omron.co.jp/product/closed/search?keyword=C200HS-
...ut Unit, 16 points CS1W-ID211 CJ1W-ID211 NX-ID5142-1 Interrupt Input Unit, 16 points CS1W-INT01 CJ1W-INT01 NX-ID5142-1 Quick-response Input Unit, 16 points CS1W-IDP01 CJ1W-IDP01 NX-ID5142-1 T...
https://www.fa.omron.com.cn/data_pdf/cat/cj1w-at6___cj1w-cm2__-___p168-e1_4_1_csm1130527.pdf
...1W-AD081-V1 CJ1W-AD081-V1 --- Interrupt Input Unit 16 points 24 VDC 7 mA CS1W-INT01 24 VDC 7 mA CJ1W-INT01 24 VDC 7 mA NX-ID5142-1 CJ1W-AT611 *2 Quick- response Input Unit 16 points 24 VDC 7 ...
https://www.fa.omron.com.cn/data_pdf/cat/cj1w-at6___cj1w-cm2__-___p169-e1_2_1__csm1131235.pdf
... 继电器输出单元16点CS1W-OC211 CJ1W-OC211 DC输入单元16点CS1W-ID211 CJ1W-ID211 NX-ID5142-1 中断输入单元16点CS1W-INT01 CJ1W-INT01 NX-ID5142-1 快速响应输入单元16点CS1W-IDP01 CJ1W-IDP01 NX-ID5142-...
https://www.fa.omron.com.cn/data_pdf/cat/cj1w-at6___cj1w-cm2__-___sbca-cn5-143c.pdf