IAグローバル検索 |
...1 CSM_G3J-T_DS_E_3_4 Soft-start/stop Solid State Contactors G3J-T Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically •Function like an inverter by...
https://www.fa.omron.com.cn/data_pdf/cat/g3j-t_ds_e_3_4_csm157.pdf
...CSM_G3J_DS_C_4_8 1 400-820-4535 www.fa.omron.com.cn䆶⬉䆱᳔ᮄֵᙃܡ䌍 ⬉䆱三相电机用固态接触器(单功能型)G3J 三相电机用固态接触器,可以像接触器一样使用 •取得UL/CSA、CCC标准认证。 •DIN导轨...
...1 CSM_G3J_DS_E_4_5 Simple Solid State Contactors G3J Solid State Contactors That Can Drive 3- phase Motors Frequently •Certified for UL, CSA, and CCC. •Mount with screws or to DIN tr...
https://www.fa.omron.com.cn/data_pdf/cat/g3j_ds_e_4_5_csm160.pdf
...䰆ᡸ㔽时序图 S1:安全限位开关搭载直接断开机制(NC) (D4B-N、D4N、D4F) S2:限位开关(NO) S3:复位开关 KM1和KM2:磁性接点 KM3:G3J固态接点(G3J) M:3相电机 PLC䗉ޛ PLC䗉࠰ KM3 䲆փᔶީ S1ૂS2 གྷ...
https://www.fa.omron.com.cn/data_pdf/cat/g9sa_ds_c_10_13.pdf
... •Փ⫼䚼Ё㒻఼ⲥࡳ㛑DŽ˄Փ⫼PDMᓔਃEDMࡳ㛑DŽ˅ •Փ⫼⌟䆩䕧ܹDŽ˄Փ⫼PDMᴹਃ⫼⌟䆩䕧ܹDŽ˅ S1˖䚼⌟䆩ᓔ݇ S2˖ਃࡼ䕧ܹ KM1ǃKM2˖⺕ᗻ㾺఼ KM3˖ᗕ㾺఼(G3J) M˖3Ⳍ⬉ᴎ E1˖DC24V⬉⑤ PLC˖ৃ㓪ࠊ఼ ˄⫼ѢⲥDŽ䖭ϡሲѢᅝܼ㋏㒳DŽ˅ *䕙ࡽ䕧ߎⱘ䕧ߎ᪡ᓣЎPNPࠊ䕧ߎৠ...
https://www.fa.omron.com.cn/data_pdf/cat/ms4800_ca_c_7_4.pdf
... External test switch S2: Start input KM1, KM2: Magnetic contactors KM3: Solid-state contactor (G3J) M: 3-phase motor E1: 24-VDC power supply PLC: Programmable Controller (Used for monitoring...
https://www.fa.omron.com.cn/data_pdf/cat/ms4800_f084-e1_7_3_csm1813.pdf
... PE B 123456 JP KM2 KM1 T22 T23 T21 2 5 3 4 K1 K2 KM1、KM2:强制导向继电器(G7SA)或者电磁接触器 ED1:固态接触器(G3J) M1:3相电机 S1:启动输入(闭锁解除用) S2:区域切换开关 S3:复位开关 S4:待机...
https://www.fa.omron.com.cn/data_pdf/cat/os32c_schg-cn5-030_14_7.pdf
...ターロック/ロックアウトリセットスイッチ KM1, KM2:マグネット・コンタクタ(形LP1D) KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ E1:DC24V電源(形S82K) PLC:プログラマブルコントローラ (...
https://www.fa.omron.com.cn/data_pdf/mnu/f3sn-b_scee-717.pdf
...ターロック/ロックアウトリセットスイッチ KM1, KM2:マグネット・コンタクタ(形LP1D) KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ E1:DC24V電源(形S82K) PLC:プログラマブルコントローラ (...
https://www.fa.omron.com.cn/data_pdf/mnu/scee-713_f3sn-a.pdf
...䕙ࡽ䕧ߎ 䚼㒻⬉఼ⲥ F3SP-B1Pൟ -ࡼԡᓣ -Փ⫼䚼㒻⬉఼ⲥࡳ㛑 S1 :䚼⌟䆩ᓔ݇ S2 :Ѧ䫕/䫕ᅮԡᓔ݇ KM1, KM2 :⬉⺕㾺఼ KM3 :ᗕ㾺఼(G3J) M :3Ⳍ偀䖒 E1 :24VDC⬉⑤(S82K) PLC :ৃ㓪ࠊ఼ ˄⫼ѢⲥˈϢᅝܼಲ䏃᮴݇˅ F39-JCƶB-Lൟ F39-JC...
https://www.fa.omron.com.cn/data_pdf/mnu/sche-c-710a_f3sj.pdf
...act (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S82K) PLC :Programmable controller (Used for monitoring -...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-716n_eng_f3sj-am.pdf
...act (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S82K) PLC :Programmable controller (Used for monitoring -...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-718s_eng_f3sj-a.pdf
...act (G7SA) or magnetic contactor KM3 : Load or PLC (for monitoring) KM4 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S82K) PLC :Programmable controller (Used for monitoring -...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-719s_eng_f3sj-a.pdf
...ety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S82K) PLC :Programmable controller (Used for monitoring -...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-720r_eng_f3sj-a.pdf
...ety relay with forcibly-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor E1 :24VDC power supply (S82K) PLC :Programmable controller (Used for monitoring -...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-722n_eng_f3sj-a.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.fa.omron.com.cn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf