...而無法復歸。 請儘量縮短配線避免產生誘導電壓,且配線時避免與動力線平行。 誘導電壓為額定電壓的30%以上時,請將CR濾波器 (C=0.1μF、R=120Ω程度)或洩流器電阻連接於電源端子間。 同樣的,因漏電流而...
https://www.omron.com.tw/data_pdf/cat/h3dk_sgta-037_tw_7_5.pdf
...xible Cables •750W or less R88A-CRK@@@@C •1.0kW or more R88A-CRKC@@@N •750W or less R88A-CRK@@@@CR •1.0kW or more R88A-CRK@@@NR •Non-Flexible Cables •Flexible Cables INC ABS INC 4 G5 Series L...
https://www.omron.com.tw/data_pdf/cat/r88m-k_r88d-kt_r88d-kn_-ml2_-ect_i816-e1_9_16_csm2179.pdf
...拔型) M多重输入事件输入通信远程 SP 输入加热器断线· HS报警功能传送输出 RX、QX、 RR、CQ、 QQ、QR时 CX、CC、 CR时 PR时 000─────可选可选可选 004 2点RS-485────可选可选 005 4点─────可选─ 008 2点RS-...
...协议:专用协议通信 ·奇偶校验:偶数 ·停止位:2bit ·传送速度:38400 ·H/W型:RS-485 ·校验和:打勾 ·传送控制步骤:格式4(带CR、LF) (注)变更“局号设定”时,请参照“6-2-7通信节点编号”。 6无程序通信 6 -...
...1;機號0設定為1:1連接) 封包結構C模式指令標頭(Header):@,位址:(主機連結機號)0至31(BCD),資料: header碼+內文,錯誤檢查碼:FCS,terminator:*+CR FINS指令Header:@,位址:(主機連結機號)0至31(...
https://www.omron.com.tw/data_pdf/mnu/ote-plc-01n_cs1_cj1.pdf
...ling data The 5th and later fields contain the sampling data in order. Return A line feed code, CR+LF (0x0D 0x0A), is placed at the end of the line. index 100 12 97 98 99 When the last record...
https://www.omron.com.tw/data_pdf/mnu/v237-e1-04_ws02-sptc1-v2.pdf
...--- 4 Too Many Characters in one Block Number of characters in one block exceeded 128 including CR-LF. 5 Illegal Program Start Specification of operand 'P' value at a subprogram's PROG comman...
https://www.omron.com.tw/data_pdf/mnu/w448-e1-07_cx-motion-mch.pdf
...b>[Log code]
...ir wires for pilot lamps (and particularly lamps with filaments). •Use countermeasures, such as CR surge absorbers and diodes, for input device and output load device noise sources, as requir...
https://www.omron.com.tw/data_pdf/mnu/w535-e1-18_nx701_nx-p_.pdf
...時,也會發生同樣的情況。 兩種都是因電源電壓急劇變化而導致的過渡現象。 雖然很難完全排除這種情況,但將操作線圈與CR(電容與電阻串接的產品)並聯連接即可改善。 連接在程序控制的自保持迴路之繼電器在...
...r less R88A-CRK@@@@C • 1.0kW or more R88A-CRKC@@@N • Flexible Cables • 750W or less R88A-CRK@@@@CR • 1.0kW or more R88A-CRK@@@NR • G5 Series motor R88M-K INC USB Communications Peripheral Dev...
https://www.omron.com.vn/data_pdf/cat/g5_series_i815-e1_29_32_csm2106.pdf
...e H3CR-H is influenced by inductive voltage that is 30% or more of the rated voltage, connect a CR filter with a capacitance of approximately 0.1 μF and a resistance of approximately 120 Ω or...
https://www.omron.com.vn/data_pdf/cat/h3cr_l084-e1_3_6_csm1013792.pdf
...he Timer is influenced by inductive voltage that is 30% or more of the rated voltage, connect a CR filter with a capacitance of approximately 0.1 μF and a resistance of approximately 120 Ω or...
https://www.omron.com.vn/data_pdf/cat/h3dk_l118-e1_7_7_csm2645.pdf
...r less R88A-CRK@@@@C • 1.0kW or more R88A-CRKC@@@N • Flexible Cables • 750W or less R88A-CRK@@@@CR • 1.0kW or more R88A-CRK@@@NR • External scale Reactors 3G3AX-DL 3G3AX-AL External Regenerat...
https://www.omron.com.vn/data_pdf/cat/r88m-k_r88d-kt_r88d-kn_-ml2_-ect_i816-e1_9_16_csm2179.pdf
...ding is started. The 5th and later fields contain the sampling data in order. A line feed code, CR+LF (0x0D 0x0A), is placed at the end of the line. Note Each sampling file has a maximum size...
https://www.omron.com.vn/data_pdf/mnu/v237-e1-04_ws02-sptc1-v2.pdf
...locks of programming exceeded 800. ----Number of characters in one block exceeded 128 including CR-LF. Specification of operand 'P' value at a subprogram's PROG command is greater than 1000 a...
https://www.omron.com.vn/data_pdf/mnu/w448-e1-07_cx-motion-mch.pdf
...b>[Log code]
...r wires for pilot lamps (and particularly lamps with filaments). • Use countermeasures, such as CR surge absorbers and diodes, for input device and output load device noise sources, as requir...
https://www.omron.com.vn/data_pdf/mnu/w535-e1-18_nx701_nx-p_.pdf
...hod Power supply Yes No Yes Yes Yes Inductive load Diode method Power supply Yes Inductive load CR method Characteristic Required element If the load is a relay or solenoid, there is a time l...
https://www.omron.com.vn/data_pdf/mnu/z174-e1-02a_cs1w_cj1w-v600c1_.pdf
...ith the load or contact as shown below. Circuit Current AC Yes Power supply xxii Inductive load CR method DC Yes Characteristic Required element If the load is a relay or solenoid, there is a...