CJ2M-CPU3[] / CPU1[] / MD21[] CJ-series CJ2M CPU U...

...ations Option Boards (CP1W-CIF01/CIF11/CIF12-V1),    respectively.    Add 0.15A/Unit when using NT-AL001 RS-232C/RS-422A Adapters.    Add 0.04A/Unit when using CJ1W-CIF11 RS-422A Adapters.   ...

https://www.omron-ap.com/products/family/2712/lineup.html

PDF[H175-E1-17] E5[]C Digital Temperature Controllers...

...nce is 50 m. If the total transmission distance exceeds 50 m, use an isolated model such as the NT-AL001 or the K3SC. In such a case, do not use the CJ1W-CIF11 in the transmission path. The m...

https://www.fa.omron.co.jp/data_pdf/mnu/h175-e1-17_e5_c.pdf

PDF[P069-E1-06] C200H → CS1 Replacement Guide

...53/BC052 CS1W-BC083/BC082 CS1W-BC103/BC102 Description UM 10K steps *To replace C120-LK202, use NT-AL001 to convert RS-232C into RS-422. To use RUN output, prepare an Output Unit separately. ...

https://www.fa.omron.co.jp/data_pdf/mnu/p069-e1-06_c200h_cs1_replace.pdf

PDFProgrammable Controller CS/CJ-series

...n to connect the built-in RS-232C interface on the CJ2M-CPU1£ and an RS-232C/RS-422A Converter (NT-AL001) with a cable. Refer to Connecting to a Serial Port on the CPU Unit in Appendices of t...

https://www.fa.omron.co.jp/data_pdf/mnu/p152-e1-03_cj2_-cpu_c_1w-e_cs1d-etn21d.pdf

PDF[SBCA-069E] C200H → CS1 置き換えガイド

.../BC032 CS1W-BC053/BC052 CS1W-BC083/BC082 CS1W-BC103/BC102 備考 UM 10K ステップ (*)C120-LK202 をご使用の場合は、NT-AL001 を使用して、RS232C→RS422 変換ください。 運転中出力(RUN 接点)をご...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-069e-web1_c200h_cs1_replace.pdf

PDFプログラマブルコントローラ CS/CJシリーズ 置き換えガイド

...変更します。 形 CP1W-CIF12 (RS-422A/485(絶縁)) 形 CJ2M-CPU1£の内蔵 RS-232C インタフェースと RS-232C/RS-422A 変換ユニット(形 NT-AL001)をケーブルで接続する構成に変更します。 CS/CJ シリーズ ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-135c_cj2_-cpu_c_1w-e_cs1d-etn21d.pdf

PDF[SBCA-328M] C500, C1000H, C2000H → CS/CJシリーズ リニューア...

...内蔵 RS-232C RS-232C ポート 注 1: CPU 取付タイプ上位リンクユニットとして、形 C120-LK202(RS-422A タイプ)を使用している場合は、形 NT-AL001 または形 CJ1W-CIF11 を使用して、RS-232C を RS-422A ...

https://www.fa.omron.co.jp/data_pdf/mnu/sbca-328m-1_c500_c1000h_c2000h.pdf

PDF[SGTD-741T] E5□C デジタル調節計 通信マニュアル

...配線 (注)1 形 CJ1W-CIF11 は非絶縁タイプのため、最長伝送距離は 50m です。 総伝送距離が 50m を超える場合は、絶縁タイプの形 NT-AL001 または、形 K3SC を使用してください。 この場合、伝送経路に...

https://www.fa.omron.co.jp/data_pdf/mnu/sgtd-741t_e5_c.pdf

PDFSYSMAC CP-series Programmable Controllers

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1118339-0e.pdf

PDFSYSMAC CP㌫ࡇ ᆹޘкⲴ⌘᜿һ亩 ᝏ䉒ᛘ䍝ҠᵜޜਨⲴਟ㕆〻ᒿ᧗ࡦಘ˄3/&˅DŽ

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter. The external device and the CPU Unit may be damaged....

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131255-6b.pdf

PDFSYSMAC CPࢩ࣮ࣜࢬ Ᏻ඲ୖࡢࡈὀព ࡇࡢࡓࡧࡣᙜ♫ࡢࣉࣟࢢ࣐ࣛࣈࣝࢥࣥࢺ࣮ࣟࣛ㸦PLC㸧ࢆ࠾...

...࡛ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPUࣘࢽࢵࢺ࡟⿦╔ࡋࡓRS-232C࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ6␒ࣆࣥ㸦+5V㟁※㸧ࡣࠊኚ᥮ ࢔ࢲࣉࢱᙧCJ1W-CIF11/ᙧNT-AL001௨እࡢእ㒊ᶵჾ࡟ࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ 㒊ᶵჾ࠾ࡼࡧCPUࣘࢽࢵࢺࡀᨾ㞀ࡍࡿᜍࢀࡀ࠶ࡾࡲࡍࠋ ە᥋⥆ࢣ࣮ࣈࣝࡣྛࣘࢽ...

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-1131256-4b.pdf

PDFSYSMAC CPࢩ࣮ࣜࢬ Ᏻ඲ୖࡢࡈὀព ࡇࡢࡓࡧࡣᙜ♫ࡢࣉࣟࢢ࣐ࣛࣈࣝࢥࣥࢺ࣮ࣟࣛ㸦PLC㸧ࢆ࠾...

...࡛ᣦ♧ࡉࢀࡓ᪉ἲ࡛⾜ࡗ࡚ࡃࡔࡉ࠸ࠋ ەCPUࣘࢽࢵࢺ࡟⿦╔ࡋࡓRS-232C࢜ࣉࢩ࣮ࣙࣥ࣎ࢻࡢ6␒ࣆࣥ㸦+5V㟁※㸧ࡣࠊኚ᥮࢔ ࢲࣉࢱᙧCJ1W-CIF11/ᙧNT-AL001ࠊࣉࣟࢢ࣐ࣛࣈࣝࢱ࣮࣑ࢼࣝᙧNV3W-Mڧ20L௨እࡢ እ㒊ᶵჾ࡟ࡣ᥋⥆ࡋ࡞࠸࡛ࡃࡔࡉ࠸ࠋእ㒊ᶵჾ࠾ࡼࡧCPUࣘࢽࢵࢺࡀᨾ㞀ࡍࡿᜍࢀ...

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104744-3c.pdf

PDFSYSMAC CP㌫ࡇ ᆹޘкⲴ⌘᜿һ亩 ᝏ䉒ᛘ䍝ҠᵜޜਨⲴਟ㕆〻ᒿ᧗ࡦಘ˄3/&˅DŽ

...t pin 6 (+5V) on the RS-232C Option Board on the CPU Unit to any external device other than the NT-AL001 or CJ1W-CIF11 Conversion Adapter or NV3W-Mƶ20L Programmable terminal. The external dev...

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-2104888-1c.pdf

PDFSYSMAC CPシリーズ 安全上のご注意 このたびは当社のプログラマブルコントローラ(PLC)をお...

...法で行ってください。 ●CPUユニットに装着したRS-232Cオプションボードの6番ピン(+5V電源) は、変換アダプタ形CJ1W-CIF11/形NT-AL001以外の外部機器には接続しないでください。 外部機器およびCPUユニッ...

https://www.fa.omron.com.cn/data_pdf/mnu/cpseries(safetyprecautions)_inst-4074765-0e.pdf

PDF1 Communications Methods 2 CompoWay/F Commu-

...nce is 50 m. If the total transmission distance exceeds 50 m, use an isolated model such as the NT-AL001 or the K3SC. In such a case, do not use the CJ1W-CIF11 in the transmission path. The m...

https://www.omron-ap.co.in/data_pdf/mnu/h175-e1-17_e5_c.pdf

PDFProgrammable Controller CS/CJ-series

...n to connect the built-in RS-232C interface on the CJ2M-CPU1£ and an RS-232C/RS-422A Converter (NT-AL001) with a cable. Refer to Connecting to a Serial Port on the CPU Unit in Appendices of t...

https://www.omron-ap.co.in/data_pdf/mnu/p152-e1-03_cj2_-cpu_c_1w-e_cs1d-etn21d.pdf

PDFCat. No. W394-E1-16 SYSMAC CS Series

... the RS-232C port on the CPU Unit to any external device except the CJ1W-CIF11 RS-422A Adapter, NT-AL001 RS-232C/RS-422A Adapter, or NV3W-M@20L Programmable Terminal. Doing so may damage the ...

https://www.omron-ap.co.in/data_pdf/mnu/w394-e1-16_cs_cj_nsj.pdf

PDFCat. No. W472-E1-17 SYSMAC CJ Series

...onnect pin 6 (5-V power supply) on the RS-232C port on the CPU Unit to any device other than an NT-AL001 Link Adapter, CJ1W-CIF11 Converter, and Programmable Terminals (NV3WM20L). The extern...

https://www.omron-ap.co.in/data_pdf/mnu/w472-e1-17_cj2h-cpu6_eip_cj2m-cpu.pdf

PDF1 Communications Methods 2 CompoWay/F Commu-

...nce is 50 m. If the total transmission distance exceeds 50 m, use an isolated model such as the NT-AL001 or the K3SC. In such a case, do not use the CJ1W-CIF11 in the transmission path. The m...

https://www.omron-ap.co.nz/data_pdf/mnu/h175-e1-17_e5_c.pdf

PDFProgrammable Controller CS/CJ-series

...n to connect the built-in RS-232C interface on the CJ2M-CPU1£ and an RS-232C/RS-422A Converter (NT-AL001) with a cable. Refer to Connecting to a Serial Port on the CPU Unit in Appendices of t...

https://www.omron-ap.co.nz/data_pdf/mnu/p152-e1-03_cj2_-cpu_c_1w-e_cs1d-etn21d.pdf