Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 261 - 2802084
K3HB-P 时间间隔表/额定值 / 性能 | OMRON Industrial Automatio...

...50mA 漏电流 100μA以下 DeviceNet通信 通信协议 DeviceNet标准 通信 功能 远程I/O 通信功能 • Master/Slave连接(Poll/Bit-Strobe/COS/Cyclic) • 依据DeviceNet通信协议 I/O分配设定 • 通过配置器任意分配IN...

https://www.fa.omron.com.cn/products/family/1539/specification.html

K3HB-C 累计/增减量脉冲表/额定值 / 性能 | OMRON Industrial Autom...

... 50mA 漏电流 100μA以下 DeviceNet通信 通信协议 DeviceNet标准 通信功能 远程I/O通信 功能 • Master/Slave连接(Poll/Bit-Strobe/COS/Cyclic) • 依据DeviceNet通信协议 I/O分配设定 • 通过配置器任意分配IN...

https://www.fa.omron.com.cn/products/family/1540/specification.html

K3HB-H 温度面板表/额定值 / 性能 | OMRON Industrial Automatio...

...50mA 漏电流 100μA以下 DeviceNet通信 通信协议 DeviceNet标准 通信 功能 远程I/O通信 功能 • Master/Slave连接(Poll/Bit-Strobe/COS/Cyclic) • 依据DeviceNet通信协议 I/O分配设定 • 通过配置器任意分配IN...

https://www.fa.omron.com.cn/products/family/1541/specification.html

NE1A-SCPU系列 安全网络控制器/额定值 / 性能 | OMRON Industrial Au...

... (全部单元版本) 标准从站功能 • 最多连接数:2 • 最大数据容量:输入16个字节或输出16个字节(每个连接) • 连接类型:轮询、位选通、COS、循环 信息通信 最大报文长度:552个字节 信息更新: 2021年1月15日...

https://www.fa.omron.com.cn/products/family/1625/specification.html

EJ1 模块式温控器/额定值 / 性能 | OMRON Industrial Automation

...-1): 2级污染, II类过电流 EMC指令 请参见样本。 通信特性 通信协议 符合DeviceNet。 通信功能 远程I/O通信 主从连接(轮询式、COS式或周期性) 符合DeviceNet规格。 I/O分配 用户可以用配置器随意分配输入...

https://www.fa.omron.com.cn/products/family/1757/specification.html

NE0A-SCPU01 安全网络控制器/额定值 / 性能 | OMRON Industrial Au...

...以与多达15个安全主站进行通信。 • 连接类型: 单播、多播 标准I/O通信 标准从站功能 • 最多连接数: 2 • 连接类型: 轮询、位选通、COS、循环 信息通信 最大报文长度: 502个字节 信息更新: 2021年1月15日...

https://www.fa.omron.com.cn/products/family/1984/specification.html

H5CN 石英定时器/额定值 / 性能 | OMRON Industrial Automation

...位及栅极(有接点、无接点输入共用)  最小复位输入信号宽度 0.02s  残留电压2V以下 控制输出 有接点输出 1c AC250V 3A 电阻负载(cos φ =1) 最小适用负载 DC5V 10mA (P水准、参考值) 无接点输出(集电极开...

https://www.fa.omron.com.cn/products/family/205/specification.html

3G3MX2 多功能小型变频器/额定值 / 性能 | OMRON Industrial Automa...

...格 项目 型号 证书 经DeviceNet网络符合性测试 DeviceNet网面 经DeviceNet网络符合性测试 支持的连接 远程I/O:主从连接 轮询 位选通 COS Cyclic 显式信息 符合DeviceNet网络规格 通信电源 DC11-25V (最大5...

https://www.fa.omron.com.cn/products/family/2620/specification.html

NE1A-SCPU0□-EIP 安全网络控制器/额定值 / 性能 | OMRON Industria...

...输入/输出通信 标准从站功能 • 最多连接数: 2 • 最大数据容量: 输入16个字节或输出16个字节(每个连接) • 连接类型: 轮询、位选通、COS、循环 信息通信 最大报文长度: 502个字节 信息更新: 2013年12月12...

https://www.fa.omron.com.cn/products/family/2621/specification.html

G70V I/O继电器终端/额定值 / 性能 | OMRON Industrial Automati...

...61810-1 24V DC 24V DC 0.05A L/R=0ms G70V-SID16P(-1)-C16 G70V-SOC16P(-1) single load: 250V AC 6A cos(phi)=1 16 loads: 250V AC 3A cos(phi)=1 16 loads: 30V DC 3A L/R=0ms 16 loads: 250V ...

https://www.fa.omron.com.cn/products/family/3509/specification.html

K3HB-H Temperature Indicator/Specifications | OMRO...

...ported communi- cations Remote I/O communications Master-Slave connection (polling, bit-strobe, COS, cyclic) Conforms to DeviceNet communications standards. I/O allocations Allocate any I/O d...

https://www.omron-ap.co.in/products/family/1541/specification.html

F3SJ Series Safety Light Curtain/Specifications | ...

...ncluding sensor's response time) Relay output Number of contacts 3NO+1NC Rated load 25 VAC 5 A (cos ϕ = 1), 30 VDC 5 A L/R = 0 ms Rated current 5 A Connection type Between sensors M12 connect...

https://www.omron-ap.co.in/products/family/1581/specification.html

NE1A-SCPU Series Safety Network Controller/Specifi...

...ata size: Input 16 bytes or output 16 bytes (per connection) Connection type: Poll, bit-strobe, COS, cyclic Message communications Max. message length: 552 bytes last update: December 1, 2020...

https://www.omron-ap.co.in/products/family/1625/specification.html

NE0A-SCPU01 Safety Network Controller/Specificatio...

...nications Standard Slave function Max. no. of connections: 2 Connection type: Poll, bit-strobe, COS, cyclic Message communications Max. message length: 502 bytes last update: December 1, 2020...

https://www.omron-ap.co.in/products/family/1984/specification.html

H5CX Digital Timer/Specifications | OMRON Industri...

...01 to 99.99 s Control output Models with Contact Outputs 5 A at 250 VAC/30 VDC, resistive load (cos =1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Contact materi...

https://www.omron-ap.co.in/products/family/207/specification.html

NE1A-SCPU0[]-EIP Safety Network Controller/Specifi...

...ata size: Input 16 bytes or output 16 bytes (per connection) Connection type: Poll, Bit-strobe, COS, Cyclic Message communications Max. message length: 502 bytes last update: December 1, 2020...

https://www.omron-ap.co.in/products/family/2621/specification.html

A22NK Key-type Selector Switches/Specifications | ...

...3 positions: 300,000 operations min.) (250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4) Ambient operating temperature*1 -25 to 70°C Ambient operating humidity 35% to 85% ...

https://www.omron-ap.co.in/products/family/3441/specification.html

A22NN / A22NL Pushbutton Switches/Specifications |...

...n. Electrical 500,000 operations min. (250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4) Ambient operating temperature *1 -25 to 70°C -25 to 55°C Ambient operating humidit...

https://www.omron-ap.co.in/products/family/3443/specification.html

A22NS / A22NW Selector Switches/Specifications | O...

...3 positions: 300,000 operations min.) (250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4) Ambient operating temperature *1 -25 to 70°C -25 to 55°C Ambient operating humidit...

https://www.omron-ap.co.in/products/family/3444/specification.html

A30NS / A30NW Selector Switches/Specifications | O...

...3 positions: 300,000 operations min.) (250 VAC, 3 A, with an inductive load having power factor cos θ = 0.4) Ambient operating temperature*1 -25 to 70°C -25 to 55°C Ambient operating humidity...

https://www.omron-ap.co.in/products/family/3448/specification.html

結果 261 - 2802084

国/地域選択

Related Contents