Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 281 - 3001143
PDFCat.No.V109-E1-15 STARTUP GUIDE

...- - 6 RDB+ I/O - RS485B Send/Receive data(+) Receiving data(+) 7 SDA- I/O - - Sending data(-) 8 RDA- I/O - RS485A Send/Receive data(-) Receiving data(-) 9 SG - Signal ground 1-9 1 NB Overview...

https://www.omron.com.tw/data_pdf/mnu/v109-e1-15_nb3q_nb5q_nb7w_nb10w.pdf

PDFPC Link System Manual Revised March 2000

...ion 5-1 40 Pin connections for Systems using optical links are shown below. Twist SDB with SDA; RDA with RDB. The shield wire is connected only at one end of each cable to prevent current flo...

https://www.omron.com.tw/data_pdf/mnu/w135-03_c200h-lk401_c500-lk009-v1.pdf

PDFC200H-ASC11/ASC21/ASC31 ASCII Units

...data A (–)Output 2 SDB Send data B (+) Output 3 NC Not used - 4 NC Not used - 5 NC Not used - 6 RDA Receive data A (–) Input 7 NC Not used - 8 RDB Receive data B (+) Input 9 NC Not used - Hoo...

https://www.omron.com.tw/data_pdf/mnu/w306-03_c200h-asc11_21_31.pdf

PDFW461-E1-06

... Contact C ON Contact Z ON 60.00Hz 55.00Hz 50.00Hz Stooped (W0.00) (W0.01) (W0.02) (W0.15) COMM RDA- RDB+ SDA - SDB+ FG Control circuit terminal block (communication terminals) Symbol S- S+ R...

https://www.omron.com.tw/data_pdf/mnu/w461-e1-06_cp1l_cp1e.pdf

PDFMachine Automation Controller CJ-series

... RS-422A/485, always check the polarity before you make connections. The signal names SDA/B and RDA/B do not always have the same polarity. •Do not turn OFF the power supply while writing the...

https://www.omron.com.tw/data_pdf/mnu/w494-e1-04_cj1w-scu_2.pdf

PDFEJ1 Modular Temperature Controllers

...6 COM Port C RDB (+) B (+) B7 − A6 Contact input Non-contact input A7 SD A8 RD A9 SG SDB (+) B8 RDA (−) A (−) DO NOT USE RS-422 RS-485 B9 RS-232C SDA (−) DO NOT USE RS-422 • Terminals A10 and...

https://www.omron.com.vn/data_pdf/mnu/h142-e1-10_ej1.pdf

PDFE5CN-H E5AN-H E5EN-H Digital Controllers

...AN/EN-H Controllers Option Units Communications E53-EN01 RS-232C SD 11 RDB 11 B (+) 11 12 RD 12 RDA 12 A (−) 12 13 SG 13 SG 13 DO NOT USE 13 DO NOT USE 21 SDB 21 B (+)*2 21 DO NOT USE 22 SDA ...

https://www.omron.com.vn/data_pdf/mnu/h157-e1-08_e5cn-h_e5an-h_e5en-h.pdf

PDFOverview CompoWay/F E5CN-H E5AN-H

...) RS-422 Shield No. Terminator × 2 (240 Ω, 1/2 W) E5AN/EN-H (No. 30) Overview RS-422 RS-422 No. RDA 22 SDA 22 SDA RDB 21 SDB 21 SDB SDA 12 RDA 12 RDA SDB 11 RDB 11 RDB SG 13...

https://www.omron.com.vn/data_pdf/mnu/h159-e1-04_e5cn-h_e5an-h_e5en-h.pdf

PDF1 Communications Methods 2 CompoWay/F Commu-

...cially available USB cable E5CD No.0 PORT1 FG L1 E5CD No.1 E5CD No.2 SDA- SDB+ AC100-240V INPUT RDA- RDB+ L2/N 6 Peripheral (USB) port PORT2 RUN OUTPUT AC240V DC24V The application procedure ...

https://www.omron.com.vn/data_pdf/mnu/h225-e1-04_e5_d.pdf

PDF1 Communications Methods 2 CompoWay/F Commu-

...CD-H No.2 25.0 25.0 25.0 SDA- SDB+ AC100-240V INPUT 6-5 Connecting to CJ-series PLCs CJ1W-CIF11 RDA- RDB+ L2/N Peripheral (USB) port PORT2 RUN OUTPUT AC240V DC24V 0.0 0.0 6-5-1 Configuration ...

https://www.omron.com.vn/data_pdf/mnu/h240-e1-01_e5_d-h.pdf

PDFProgrammable Controller CS1 Replace Guide

...e 1 SDA Transmission data 2 SDB Transmission data + 3 NC Not used 4 NC Not used 5 NC Not used 6 RDA Reception data 7 NC Not used 8 RDB Reception data + 9 NC Not used Hood FG Shield RS-422A/48...

https://www.omron.com.vn/data_pdf/mnu/p164-e1-02_cs1g_cs1h_cj2_replace.pdf

PDFCJ Series General-purpose Serial Connection Guide

... Pin No. 1 (See note 1.) 2 (See note 1.) 3 (See note 1.) 4 (See note 1.) 5 (See note 2.) Symbol RDA RDB SDA SDB FG Signal name Receive data Receive data + Send data Send data + Shield I/O Inp...

https://www.omron.com.vn/data_pdf/mnu/p540-e1-01_km50.pdf

PDFW461-E1-06

...ed by RS485 for frequency and start/stop control. ●Wiring Example 3G3MV CP1L CP1W-CIF11/12 COMM RDA - RDB+ SDA - SDB+ FG 1 2 3 4 5 RDARDB+ SDASDB+ FG CP1W-CIF11/12 (RS422/485 option board) 15...

https://www.omron.com.vn/data_pdf/mnu/w461-e1-06_cp1l_cp1e.pdf

PDF[1617140-3C] CJ1W-CIF21 簡易通信ユニット 取扱説明書 取扱説明書(安全上のご...

...認の上結線してください。 通電中はユニットを分解したり、内部に触れたりしない 相手機器によっては、略称 SDA/SDB、RDA/RDB と信号の+/−が でください。 感電の恐れがあります。 逆になるものがあります...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/cj1w-cif21(safetyprecautions)_inst-1617140-3c.pdf

PDF[2192564-5B] FZ4, FZD (Four Camera) Vision Sensor ...

...aximum cable length is 15 m. • RS-232C Controller Pin No. Signal name 1 SDB(+) 2 SD/SDA(-) 3 RD/RDA(-) 4 RDB(+) 5 NC 6 NC 7 NC 8 NC 9 GND Function For RS-422 For RS-232C/RS-422 For RS-232C/RS...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/fz4series(fourcamera)_inst-2192564-5b(e).pdf

PDF[I549-E1-01] 3G3RV-V1 High-function General-purpos...

...n below. Pin No. Code Signal name I/O Pin No. Code Signal name I/O 1 SDA Send data (-) Output 6 RDA Receive data (-) Input 2 SDB Send data (+) Output 7 NC - - 3 NC - - 8 RBD Receive data (+) ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/i549-e1-01_3g3rv-v1.pdf

PDF[4355927-8A] K3NR, K3NP, K3NC デジタル回転/パルスメータ、デジタルタイ...

...104 9 LL 9 使用周囲雰囲気 腐食性ガスのないこと 96 112 8 B 出力 NPNトランジスタ (DC 12~24V 50mA max.) RDA 17 C (※右側コネクターは-FLK6の場合のみ) TERMINATOR ON 26 6 3 L PASS COM H RS-422 -10...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/k3nr_k3np_k3nc_inst-4355927-8a.pdf

PDF[SBCB-309] CJシリーズ 簡易通信ユニットユーザーズマニュアル

...圧で使用してください。 RS-422/485を接続時は、必ず極性を確認の上結線してください。 相手機器によっては、略称SDA/SDB、RDA/RDBと信号の+/−が逆になるものがあります。 ● 4 ● RS-422/485で使用する場合...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbcb-309_cj1w-cif21.pdf

PDF[SBCC-539F] C500-SF410-V6/SF610-V6, FIT20-MF101-V3...

...B11 A12 (シールド線) FG B12 +RXD -RXD +TXD -TXD +CTS -CTS +RTS -RTS 上位リンク RS-422 1 6 5 9 RDB RDA SDB SDA 3 SG 7 FG 8.7 8- 5 CQM1、C200HSの接続方法 CQM1、C200HSをツールと接続する場合は...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbcc-539f.pdf

PDF[SBCE-340] 3G3RV-V1 高機能型汎用インバータ ユーザーズマニュアル

...なります。 ピン No. 記号 信号名 入出力 ピン No. 記号 信号名 入出力 1 SDA 送信データ- 出力 6 RDA 受信データ- 入力 2 SDB 送信データ+ 出力 7 NC - - 3 NC - - 8 RBD 受信データ+ 入力 4 NC ...

https://www.fa.omron.co.jp/data_pdf/closed/mnu/sbce-340_3g3rv-v1.pdf

結果 281 - 3001143