IAグローバル検索 |
...CSM_CJ1W-B7A_DS_E_3_2 1 CJ-series B7A Interface Unit CJ1W-B7A It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, •T...
https://www.fa.omron.com.cn/data_pdf/cat/cj1w-b7a_ds_e_3_2_csm1638.pdf
... •DC Input/Transistor Output Units CS1W-MD29@ Other Units --- •Interrupt Input Units CS1W-INT01 B7A Interface Units •32 inputs CS1W-B7A12 •32 outputs CS1W-B7A02 •16 inputs and 16 outputs CS1W...
https://www.fa.omron.com.cn/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_22_csm1004122.pdf
...ut Units CS1W-MD29@ Other Units Safety Relay Unit CS1W-SF200 Interrupt Input Unit CS1W-INT01 B7A Interface Units (32 inputs) CS1W-B7A12 (32 inputs) CS1W-B7A02 (16 inputs, 16 outputs) CS1W-...
https://www.fa.omron.com.cn/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_15_csm1004120.pdf
.../O单元和CPU总线单元单元/产品型号宽度 I/O控制单元CJ1W-IC101 20 32点基本I/O单元 CJ1W-ID231/232/233 CJ1W-OD231/232/233/234 B7A接口单元 CJ1W-B7A22 CJ1W-B7A14 CJ1W-B7A04 CompoBus/S主站单元CJ1W-SRM...
https://www.fa.omron.com.cn/data_pdf/cat/csm_cj1g_cj1h_cj1w_cj1m_ca_c_10_6.pdf
...传感器 •以较低操作力(0.3N)测量玻璃、塑料、橡胶等各种被测物体。 •测量范围0~5mm,备有4~20mA线性输出和数字输出 (支持B7A通信)2种。 •测定头有球型、针型、扁平型3种,可根据被测物体选择。 •采用...
..._DS_C_10_3 1 400-820-4535 www.fa.omron.com.cn䆶⬉䆱᳔ᮄֵᙃܡ䌍 ⬉䆱数字显示单元(字符高度80/120/200mm)M7E 内置1对1传输功能(B7A输出), 可节省配线的数字显示单元 •字符高度80、120、200mm,显示颜色...
https://www.fa.omron.com.cn/data_pdf/cat/m7e(80_120_200mm)_ds_c_10_3.pdf
...ital Display (80/120/200 mm) M7E Digital Display with Wire-saving Serial Transmission Function (B7A Output) •Single-color (red or green) and three-color (red, green, or orange selectable) dis...
https://www.fa.omron.com.cn/data_pdf/cat/m7e(80_120_200mm)_ds_e_10_3_csm34.pdf
...BUS),ComBus/S,ComBus/L),SYSMACNET LINK系統或SYSMACLINK系統。 所有迭些系統均可与C200HX/C200HG/C200HE朕合工作。 男外迷可連接B7A接目単元。 附景B"性能規格"提供逮些単元的枝木数据。 SYSMACI,INK系統...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zci96201a_c200hx_c200hg_c200he.pdf
...T3㏄ NT31/Nr31C 所用支持工具 NT-ZJ3ATl/ZJCATl-EV2或NT-ZA3AT-EV2 NT-刀3AT1-Z∫CAT1-EV2 Dlpi序X 単元背后 尤(軟件汲置) B7A単元的使用 能 不能内存単元的使用 不能 能 RS-232C接目 連接器(9針)也用作画...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zco98503a_nt31_nt31c.pdf
...。 区域 萢圃 注韓 IR区域1 VO区域1 IROOO~IRO29 按槽位置分配給CPU枕梁和抄展1/0机架的1/0字。 組一2高密度VO単元和B7A接目単元区域1 IRO30~IRO49 分配絵組一2高密度1/O単元和組一2B7A接目単元(0~9)。 ...
https://www.fa.omron.com.cn/data_pdf/mnu/oez-zcp97201a_c200hx_c200hg_c200he.pdf
...e The Extended I/O Input table sets the usage of input terminals of an extended I/O unit (e.g., B7A Unit). For the individual input terminals, a function is set or a PC (PLC) bit to be refer-...
https://www.fa.omron.com.cn/data_pdf/mnu/v061-e1-06_nt-zjcmx1-v4.pdf
...-EV4 or NT-ZA3AT-EV2 NT-ZJCAT1-EV4 DIP switches On rear of unit None (software settings) Use of B7A unit Possible Not possible Use of memory unit Not possible Possible RS-232C interface Conne...
https://www.fa.omron.com.cn/data_pdf/mnu/v064-02_nt31_nt31c_nt631_nt631c.pdf
...2KF68 V680S-D2KF68M V680S-D8KF68 V680S-D8KF68M RF Tags Programmable Controllers, Link Terminal (B7A), I/O Relay Terminal etc. V680-HS51 V680-HAM81 V680-HAM91 Sensor Controller V680-D1KP53M V6...
https://www.fa.omron.com.cn/data_pdf/mnu/z279-e1-09_v680-ham91_ham81.pdf
...ing Label Power Supplies/In Addition K8DS JUL-SEP 2022 Packing Label Power Supplies/In Addition B7A OCT-DEC 2021 Unit Label Category Model Implementation period Display change pattern Power S...
https://www.ia.omron.com/information/data_pdf/fy23-1q_ukca-for-gsite_20231013.pdf
...elay Unit CS1W-SF200 Interrupt Input Unit CS1W-INT01 Quick-response Input Unit CS1W-IDP01 B7A Interface Units (32 inputs) CS1W-B7A12 (32 inputs) CS1W-B7A02 (16 inputs, 16 outputs) CS1W-...
https://www.omron-ap.co.in/data_pdf/cat/cs1g_cs1h_cs1w_cs1d_p047-e1_14_15_csm1004120.pdf
... to 26.4 V) Output Voltage (−5 to 5 V), current (4 to 20 mA) Current (4 to 20 mA) Current (4 to B7A serial 20 mA) communicat ions Reference page 8 18 23 6 Approx. 0.25 N 0.5% FS max. IP54 5 N...
https://www.omron-ap.co.in/data_pdf/cat/d5sn_d5m_d5v_x071-01.pdf
... Unit DC Input/ Transistor Output Units TTL I/O Unit Interrupt Input Unit High-speed Input Unit B7A Interface Units Model Current consumption at 24 V (A) --- Name Model Analog Input Units CJ1...
https://www.omron-ap.co.in/data_pdf/cat/p04e-en-03a+cj1+groupcat.pdf
...AT1-EV4 or NT-ZA3ATEV2 NT-ZJCAT1-EV4 DIP switches On rear of PT None (software settings) Use of B7A Unit Possible Not possible Use of Memory Unit Not possible Possible RS-232C interface Conne...
https://www.omron-ap.co.in/data_pdf/mnu/v062-e1-06_nt31_31c_setup.pdf
... NT-ZA3AT-EV2 NT-ZJCAT1-EV4 DIP switch settings On rear of unit None (software settings) Use of B7A Interface Unit Possible Not possible Use of Memory Unit Not possible Possible RS-232C inter...
https://www.omron-ap.co.in/data_pdf/mnu/v069-e1-03_nt21_nt31_nt631.pdf
...ms to IP66 for spatter-, water-, and oilresistance. • Provides three FA connector ports for the B7A for 10 input points on each of 3 ports. Remote Adapters • Used in combination with G70D and...
https://www.omron-ap.co.in/data_pdf/mnu/w347-e1-06_c200hw_cqm1-drt_drt1.pdf