IAグローバル検索 |
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.omron.com.vn/data_pdf/mnu/schg-732k_eng_f3sj-e____p25_b____p25.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.omron.com.vn/data_pdf/mnu/schg-733j_eng_f3sj-e____n25_b____n25.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.omron.com.vn/data_pdf/mnu/schg-734j_eng_f3sj-b____p25-01ts.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.omron.com.vn/data_pdf/mnu/schg-735j_eng_f3sj-b____n25-01t.pdf
...Safety relay with force-guided contact (G7SA) or magnetic contactor KM3 :Solid state contactor (G3J) M :Motor PLC :Programmable controller (Used for monitoring -- not related to safety system...
https://www.omron.com.vn/data_pdf/mnu/schg-736j_eng_f3sj-b____p25-02ts.pdf
... 42 KM2 KM1, KM2: Forced guided relay (G7SA) or magnetic contactor ED1 : Solid state contactor (G3J) M : 3-Phase Motor S1 : Start Input (use for releasing lockout) S2 : Zone Select Switch S3 ...
...図の通りです。 F3S-A S1:リセットスイッチ KM1、KM2:マグネット・コンタクタ(形LP1D) KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ E1:DC24V電源(形S82K) E2:DC24V電源(形S82K) アン...
...名または端子番号 S1:リセットスイッチ(NO接点) KM1、KM2:マグネット・コンタクタ KM3:ソリッドステート・コンタクタ(形G3J) M:三相モータ E1、E2:DC24V電源(形S82K) 1/2 ] ] 制御出力 用 COM ...
https://www.fa.omron.co.jp/data_pdf/closed/cat/f3ss_ds_j_2_3.pdf
...14 23 24 K1 K2 K3 K1 K2 K3 S1:紧急停止开关 S2:复位开关(瞬时动作开关) KM1、KM2:磁接触器 KM3:固态接触器(G3J) M:3相电动机注.上述电路例相当等级4。 ●动作图 ㋻ᗹذℶᓔ݇S1 ԡᓔ݇S2 K3 b⚍ K3 a⚍ ...
https://www.fa.omron.com.cn/data_pdf/closed/cat/cqm1-sf200_cs1w-sf200_ds_c_1_1.pdf
... stop switch S2: Reset switch (momentary operation switch) KM1 and KM2: Magnetic Contactor KM3: G3J Solid-state Contactor M: 3-phase motor Note: This circuit conforms to category 4. PLC outpu...
https://www.fa.omron.com.cn/data_pdf/closed/cat/cqm1-sf200_cs1w-sf200_ds_csm1285.pdf
...5 a b K1 K2 6 a b K1 K2 1 M 动作流程图 S1:复位开关 KM1、KM2:电磁接触器 KM3:固态接触器(G3J) M:3相电机 E1、E2:DC24V电源(S82K) K1、K2 b K1、K2 a KM1、KM2 b KM1、KM2 a PLC PLC KM3 S1 F3S...
https://www.fa.omron.com.cn/data_pdf/closed/cat/f3sl_ds_c_1_1.pdf
...Yellow) Shield P.E. 24VDC (White x 2) KM1, KM2: Forced guided relay KM3: Solid state contactor (G3J) M1 : 3-Phase Motor S1 : Start Input (use for releasing lockout) S2 : Zone Select Switch S3...
https://www.fa.omron.com.cn/data_pdf/closed/mnu/schg-723b-1_os3101.pdf
...perature is the temperature of the air that dissipates the heat of the SSR. PDF Download(729KB) G3J-T Soft-start/stop Function Starts and Stops Three-phase Motors Smoothly and Economically G3...
https://www.ia.omron.com/support/guide/31/further_information.html
...he informa- tion contained in this publication. TABLE OF CONTENTS ii SECTION 1: Features of the G3J 1 . . . . . . . . . . . . . . . . . . . 1-1 Starting and Stopping the Motor 1 . . . . . . ....
https://www.omron.com.tw/data_pdf/closed/mnu/j110-02_g3j-s_-t.pdf
...directly switching loads. G3PX G3PA G3NA G3NE G3NH Single-phase G3PB Three-phase G3PB G3NA G3NE G3J G3TB G3DZ G3RZ G3TA G3R (I/O) G3S (D) G3MB G3M G3NA G3DZ G3CN G3MC G3F G3H G3B G3R 12 Basic...
https://www.omron.com.tw/data_pdf/closed/mnu/y108-01_solid_state_relays.pdf
...一覽表註.一覽表中僅揭示概略的規格。 請務必在確認各頁面的詳細規格及注意事項後再使用。 分類三相馬達用型號G3J-T-C G3J-T G3J-S G3J 產品名稱三相馬達用固態接觸器 (內置軟...
https://www.omron.com.tw/solution/selection/18/SSR_ST_TW_2_3.pdf
...認定) 註. 一覽表中僅揭示概略的規格。請務必在確認各頁面的詳細規格及注意事項後再使用。 分類 三相馬達用 型號 G3J-T-C G3J-T G3J-S G3J 產品名稱 三相馬達用 固態接觸器 (...
https://www.omron.com.tw/solution/selection/18/func_spec.html
...S2:リセットスイッチ(モーメンタリ動作スイッチ) KM1、KM2:マグネット・コンタクタ KM3:ソリッドステート・コンタクタ(形G3J) M:3相モータ注. 上記回路例はカテゴリ4相当になります。 リセットスイ...
https://www.fa.omron.co.jp/data_pdf/closed/cat/cqm1-sf200_cs1w-sf200_ds_j_2_1.pdf
...MPCEモニタ ︵桃︶ 24 S1:リセットスイッチ KM1、KM2:マグネット・コンタクタ KM3:ソリッドステート・コンタクタ (形G3J) M:三相モータ E1、E2:DC24V電源(形S82K) 24 +DC24V E1 0V Ground PLC ...
https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sl_ds_j_3_2.pdf
...イッチ (スイッチが不要な場合、X1とH1を接続) KM1、KM2:マグネット・コンタクタ KM3 :ソリッドステート・コンタクタ(形G3J) M :三相モータ E1 :DC24V電源(形S82K) PLC :プログラマブルコントロ...
https://www.fa.omron.co.jp/data_pdf/closed/cat/f3sn-a_f3sn-b_f3sh-a_ds_j_4_2.pdf