IAグローバル検索 |
...をしてください。 <サージ対策について> 電源ラインにサージがある場合、 使用環境に応じてツェナーダイオードZD...
https://www.omron-ap.co.nz/data_pdf/mnu/ee-sx97__inst-3705135-1c.pdf
... 26.2 (61.2) Connections Internal Circuit Diagram Indicator Solenoid 10 to 115 VAC/VDC 24 VDC R ZD R E1 (+) LED E2 (−) Constant-current diode 9 D4BL Circuit Connection Example • Terminals 11 ...
https://www.omron-ap.co.th/data_pdf/cat/d4bl_ds_e_10_7_csm1241.pdf
...ction device. 7 D4JL/D4JL-SK40 Connections Internal Circuit Diagram Indicator 24 VDC O1 (+) D R ZD LED O2 () Solenoid 24 VDC E1 (+) E2 () 8 D4JL/D4JL-SK40 Operation Method Operation Principle...
https://www.omron-ap.co.th/data_pdf/cat/d4jl_d4jl-sk40_ds_e_10_7_csm1239.pdf
...al load beforehand. Connections Internal Circuit Diagram Solenoid Indicator 10 to 115 VAC/VDC R ZD R 24 VDC E1 (+) LED 110 VAC E1 (+) E2 () E2 (−) Constant-current diode 6 D4NL Operation Meth...
https://www.omron-ap.co.th/data_pdf/cat/d4nl_ds_e_9_9_csm1240.pdf
...K10-LK@ Connection Internal Circuit Diagram Without indicator 9 24VDC E1 (+) With indicator D 9 ZD 10 Control circuit D R D E2 (−) Note: The numbers in boxes are the terminal numbers given on...
https://www.omron-ap.co.th/data_pdf/cat/d4sl-n_c146-e1_8_8_csm1004285.pdf
...reen) NPN output Self-diagnosis Function Black Output Proximity Sensor main circuit 100 mA max. ZD 2.2 Ω Blue 3.9 Ω 0V ZD ZD : VZ = 40 V Orange Self-diagnostic output 50 mA ...
https://www.omron-ap.co.th/data_pdf/cat/e2c_e2c-h_ds_e_9_7_csm445.pdf
...Load (relay) Brown Load (Orange) Main circuit 4 Black 100 mA max. (control output) 12 to 24 VDC ZD Operate Release (Between brown and black) Incident light No incident light 1 3 Blue Brown Op...
https://www.omron-ap.co.th/data_pdf/cat/e365-e1-01+e3f3+datasheet.pdf
...Control Load output) (Relay) Black 4 100 mA max. Photoelectric Sensor main circuit 10 to 30 VDC ZD 3 Blue Connector Pin Arrangement D Side (DARK ON) 1 2 4 3 Note: Pin 2 is not used. Through-b...
https://www.omron-ap.co.th/data_pdf/cat/e3s-a_ds_e_13_1_csm1296.pdf
...T61(-M1J) * E3S-CR11(-M1J) E3S-CR61(-M1J) Output circuits 4 Load current Black * Control output ZD 3 Incident light No incident light 0V Blue * Set the NPN or PNP selector to NPN. Light indic...
https://www.omron-ap.co.th/data_pdf/cat/e3s-c_ds_e_9_4_csm424.pdf
...nge) ON Output transistor OFF Load (relay) Operation selector Photoelectric Sensor Main Circuit ZD Load Load current Black NPN and PNP output selector NPN output transistor D side (DARK ON) 1...
https://www.omron-ap.co.th/data_pdf/cat/e3s-cl_ds_e_5_5_csm425.pdf
...r Brown Load (relay) (Green) Photoelectric Sensor main circuit 100 mA max. 4 Black 10 to 30 VDC ZD 3 Incident light Blue No incident light Light indicator ON (Red) OFF Dark-ON Output transist...
https://www.omron-ap.co.th/data_pdf/cat/e3s-r_ds_e_10_5_csm428.pdf
...2 to 24 VDC 1 Stability indicator (green) (Control output) *1 Black 50 mA max.*2 Load (relay) 4 ZD Blue 3 0V Through-beam Emitters Brown 1 Light incident Light interrupted E3T-@@@2(F) E3T-@@@...
https://www.omron-ap.co.th/data_pdf/cat/e3t_e407-e1_6_6_csm2648.pdf
... Photoelectric Sensor Main Circuit leads) Load (relay) 100mA max. Black (Control output) 4 (S1) ZD Blue 0V 3 Connector Pin Arrangement D side (DARK ON) 1 and black Incident light No incident ...
https://www.omron-ap.co.th/data_pdf/cat/e3z-g_ds_e_9_4_csm434.pdf
... Connect the pink wire (2) to the brown wire (1). 12 to 24 VDC FGS Load (relay) 100 mA max. BGS ZD FAR VERY FAR Operation indicator (orange) Output transistor Brown Stability indicator (green...
https://www.omron-ap.co.th/data_pdf/cat/e3z-ls_ds_e_9_4_csm436.pdf
... Receivers, Retro-reflective Models 4 Dark-ON (Control output) 100 mA max. 4 Load (Relay) Black ZD Blue 3 M8 4-pin Connector Pin Arrangement D side (DARK ON) 4 2 4 1 leads) 3 Pin 2 is not use...
https://www.omron-ap.co.th/data_pdf/cat/e3z-lt_lr_ll_ds_e_7_3_csm2158.pdf
... Operation indicator (orange) 1 Stability indicator (green) Photoelectric Sensor main circuit 4 ZD 3 Brown Black 12 to 24 VDC 100 mA Load (relay) max. Blue 0V Protection for NPN output models...
https://www.omron-ap.co.th/data_pdf/cat/e3z_ds_e_18_8_csm438.pdf
...t Teaching indicator (red) 10 to 30 VDC Brown 4 Load (Relay) Black 100 mA max. (Control output) ZD 3 2 Blue 0V Dark ON Pink M8 Connector Pin Arrangement 2 4 1 3 Operation indicator (Yellow) B...
https://www.omron-ap.co.th/data_pdf/cat/e3zm-b_ds_e_4_9_csm2160.pdf
...tability indicator (green) 10 to 30 VDC Brown (Control output) Load (Relay) 100 mA max. 4 Black ZD 3 Blue 0V Operate Reset (Between brown (1) and black (4) leads) Load (e.g., relay) NEAR FAR ...
https://www.omron-ap.co.th/data_pdf/cat/e3zm-c_ds_e_5_1_csm2161.pdf
...Circuit D side (DARK ON) Brown 10 to 30 VDC 1 (Control output) Load (Relay) 100 mA max. 4 Black ZD Blue 3 0V Through-beam Emitter Brown Power indicator (green) 1 Photoelectric Sensor Main Cir...
https://www.omron-ap.co.th/data_pdf/cat/e3zm_ds_e_6_1_csm2159.pdf
... (red) OFF ON Output transistor OFF Operates Load (e.g., relay) Releases Black (Control output) ZD Sensing object EE-SA701-R 12 to 24 VDC ZD EE-SA701P-R ON with no load OFF with no l...
https://www.omron-ap.co.th/data_pdf/cat/ee-sa701_801_ds_e_4_3_csm662.pdf