IAグローバル検索 |
...Pin CD RD SD ER SG DR RS CS C1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 K3SC-10 Name Name PWR NC SG PWR SD RD SG RDA(−) SDA(−) NC RDB(+) SDB(+) RS-485 Pin 7 8 9 10 11 12 (See note.) S8AS A(−) B(+) Clamp...
...工具用端口与计算机通过USB- 串行转换电缆E58-CIFQ2连接起来 •将带RS-422/RS-485通信功能的机型与计算机通过通信转换器K3SC进行连接 •将带红外线通信功能的产品(E5EN-H/E5EN-HT、E5AN-H/E5AN-HT)与计算机...
https://www.fa.omron.com.cn/data_pdf/cat/e5_n_e5_n-h_e5_n-ht_ca_c_9_2_discon.pdf
...定。 R和S热电偶在200°C温度以下的显示精度为±3°C±1位以内。 2.对于E5EZ-PRR@03型产品,为了满足EN61326CLASSA的传导和辐射规格,K3SC单元和控制器之间的通信线上应套上一个磁环(TDK:ZAT1730-0730)。 3.工...
...SSA, a magnetic ring (TDK: ZAT1730-0730) should be added to the communications line between the K3SC unit and the controller. 3. Industrial electromagnetic environment (EN/IEC 61326-1 Table 2...
https://www.fa.omron.com.cn/data_pdf/cat/e5_z_h209-e1_2_2_csm2153.pdf
...CC-U, E5EC, E5EC-B, E5AC, E5DC, E5DC-B, E5CC-T, E5EC-T, E5AC-T, E5CD, E5CD-B, E5ED or E5ED-B •A K3SC Interface Converter is used to connect a computer to models with RS-422/RS-485 communicati...
https://www.fa.omron.com.cn/data_pdf/cat/ej1_h236-e1_4_1_csm1121137.pdf
...设定工具用端口和计算机之间通过USB-串行转换电缆E58-CIFQ1连接 ·带RS-422/RS-485通信功能的型号和计算机通过通信转换器K3SC连接 ·带红外线通信的型号(E5EN-H、E5AN-H)和计算机通过USB-红外线转换电缆E58-C...
https://www.fa.omron.com.cn/data_pdf/cat/ej1_sgtd-cn5-045e.pdf
...ON OFF •上限•上下限 •下限选择上下限,比较值的上/下限值可单独设定,并通过OUT1、OUT2显示。 RS-232C RS-485 䙐ؗ䖢ᦘಞ K3SC 2 400-820-4535 www.fa.omron.com.cn咨询电话最新信息免费电话 K3GN 型号结构 ■...
...A (连接器) 173 根据通信错误的当前状况来确定错误第7-4章状态可能的成因对策无法在线连接连接连接端口 K3SC-10:接口转换器未对EJ1供电从EDU电源端子供电未对接口转换器供电对接口转换器供电 EST2-2C-MV3...
https://www.fa.omron.com.cn/data_pdf/mnu/ej1_operation_manual.pdf
...节点的主机(即将终端连接器连接到两端)。 最大端子电阻为54Ω。 对于此通信,为了满足EN61326 CLASS A中传导妨害的规格值,设备K3SC 和控制器之间的通信线加上磁环(TDK:ZAT1730-0730)。 通信单元连接图...
https://www.fa.omron.com.cn/data_pdf/mnu/h02-cn-01_e5ez-prr.pdf
...通信。 在RS-232C与RS-485接口的变换中,请使用以下的变换器等设备。 推荐产品:连接适配器K32-23209(欧姆龙生产) 通信变换器K3SC(欧姆龙生产) (K3SC的电源电压有AC100V型和AC/DC24V型,请在...
https://www.fa.omron.com.cn/data_pdf/mnu/h05z-cn-01_e5az_e5ez_e5ez-prr_e5cz.pdf
...ommunications with the host computer are carried out through a standard RS-485 interface. Use a K3SC Interface Converter for RS-485 interface conversion. ■Wiring RS-485 •The RS-485 connection...
https://www.fa.omron.com.cn/data_pdf/mnu/h133-e1-01_e5cn-fr.pdf
...程终端的通信 第8章根据现象推测(通信异常) 8-12 错误及其处理状态推测原因措施无法在线连接 [连接形态] K3SC-10 PC EJ1 (RS-232C) (RS-485) [连接端口] 连接端口 PC串行端口 EJ1 (EDU) 端口A EJ1未接通...
... E58-CIFQ1 USB-Serial Conversion Cable is required to connect the CX-Thermo. You can also use a K3SC-10 Interface Converter to convert to RS-232C/RS-485 and thereby enable connecting to more ...
https://www.fa.omron.com.cn/data_pdf/mnu/h192-e1-02_ej1n-hfuc-ect.pdf
... CLASS A transmission protection standards, add a magnetism link (TDK:ZAT1730-0730) between the K3SC and the controller. ●RS-485 connection can be 1:1 or 1:N. When using 1:N connections, a ma...
https://www.fa.omron.com.cn/data_pdf/mnu/h200-e1-01_e5ez-prr.pdf
... emission test, add a clamp filter (TDK: ZAT1730-0730) in the com- munications line between the K3SC and the Temperature Controller. •The RS-485 connection can be either one-to-one to one-to-...
https://www.fa.omron.com.cn/data_pdf/mnu/h205-e1-01_e5az_e5ez.pdf
...。 主机设备的组合端电阻至少需为54Ω。 未向控制器提供规定的电源电压。 提供规定的电源电压。 未向接口转换器(如K3SC)提供规定的电源电压。 提供规定的电源电压。 同一通信线路上的所有控制器、主机设备...
https://www.fa.omron.com.cn/data_pdf/mnu/h207-cn5-01_e5cz_e5cz-u_e5az_e5ez.pdf
...The specified power supply voltage is not being supplied to an Interface Converter (such as the K3SC) . Supply the specified power supply voltage. The same baud rate and communications method...
https://www.fa.omron.com.cn/data_pdf/mnu/h207-e1-01_e5az_e5cz_e5cz-u_e5ez.pdf
...毫秒。 1.1通信方式的概要 1-4 概述 接口通过一个标准的RS-485接口或RS-232C接口和主机进行通信。 使用一个K3SC接口转换器对RS-485和RS-232C接口进行转换。 配线RS-485 z连接形态为1对1或1对多。 1对多连...
https://www.fa.omron.com.cn/data_pdf/mnu/h208-cn5-01_e5cz_az_ez.pdf
...ter are carried out through a standard RS-485 interface or RS-232C interface (E5AZ/E5EZ). Use a K3SC Interface Converter for RS-485 and RS-232C interface conversion. Wiring RS-485 •The RS-485...
https://www.fa.omron.com.cn/data_pdf/mnu/h208-e1-01_e5cz_e5ez_e5az.pdf
.... ■Interface The host must perform communications that comply with an RS-485 interface. Use the K3SC to convert between the RS-485 and an RS-232C interface. KM50-C/E Host (e.g., computer) Com...
https://www.fa.omron.com.cn/data_pdf/mnu/n165-e1-01_km50.pdf