IAグローバル検索 |
... 300 Ω” to “300 Ω or higher.” Page 55: Changed “S82H-series and S82Jseries” to “S82J-series and S82K-series.” Pages 91 and 112: Moved DRT1-series Analog Slaves to separate table after DRT1-se...
https://www.fa.omron.co.jp/data_pdf/mnu/w267-e1-13_devicenet.pdf
...Supply Use a power supply that conforms to specifications of at least 24 VDC and 3.5 W. OMRON’s S82K-00724 is recommended (input: 100 VAC; output: 24 VDC, 7.5 W). Note The above power supply ...
https://www.fa.omron.co.jp/data_pdf/mnu/w318-e1-05_srm1_v2.pdf
...ure that the backup power supply being used meets these specifications. (We recommend the OMRON S82K-series Power Supplies.) Item Specification Voltage 24 V DC Allowed voltage fluctuation 20....
https://www.fa.omron.co.jp/data_pdf/mnu/w367-e1-02_cs1w-slk11_21.pdf
...n output voltage of 30 Vr.m.s and a 42.4-V peak or maximum of 60 VDC. Recommended power supply: S82K-10024 (OMRON) or S8J-10024D (OMRON) Recommended Wire Type Stranded wire Solid wire Pin ter...
https://www.fa.omron.co.jp/data_pdf/mnu/w454-e1-04_grt1-drt.pdf
...n output voltage of 30 Vr.m.s and a 42.4-V peak or maximum of 60 VDC. Recommended power supply: S82K-10024 (OMRON) or S82J-10024D (OMRON) Recommended Wire Type Stranded wire Solid wire Pin te...
...ltage of 30 Vr.m.s and a 42.4-V peak or maximum of 60 VDC. We recommend these Power Supplies. • S82K-10024 (from OMRON) • S82J-10024D (from OMRON) 4-2-3 Power Supply Terminals The power suppl...
https://www.fa.omron.co.jp/data_pdf/mnu/w476-e1-02_grt1-crt.pdf
...DC power supply based on the surge current. The following OMRON power supplies are recommended. S82K-05024: 100 VAC, 50 W S82K-10024: 100 VAC, 100 W *3 Refer to A-1 Dimensions for de...
https://www.fa.omron.co.jp/data_pdf/mnu/w490-e1-03_cj1w-ad0__-___da0_mad42.pdf
...ut current 500 mA DC min. Safety standard UL Class 2 Recommended model Manufacturer OMRON Model S82K-01524 Be sure to replace the cover after wiring. CIDRW System User’s Manual 31 SECTION 2 I...
https://www.fa.omron.co.jp/data_pdf/mnu/z167-e1-06a_v640-ham11-v2_hs61_v700-l22_11.pdf
....) p.4-11 Power Supply DC24V ( 10%) Recommended parts (1) When 1 Sensor Controller is connected S82K-01524 (DC24V, 0.6 A) (2) When 2 to 3 Sensor Controllers are connected S82K-05024 ...
.... Power Supply DC24V ( +-10%) p.2-5 Recommended parts (1) When 1 Sensor Controller is connected S82K-01524 (DC24V, 0.6 A) (2) When 2 to 3 Sensor Controllers are connected S82K-05024 ...
https://www.fa.omron.co.jp/data_pdf/mnu/z209-e1-03_zs-mdc.pdf
...red data) Power supply DC24V ( 10%) Recommended parts (1) When 1 Sensor Controller is connected S82K-01524 (DC24V, 0.6 A) (2) When 2 or 3 Sensor Controllers are connected S82K-05024 ...
https://www.fa.omron.co.jp/data_pdf/mnu/z210-e1-04_zs-dsu.pdf
...ut current 500 mA DC min. Safety standard UL Class 2 Recommended model Manufacturer OMRON Model S82K-01524 Be sure to replace the cover after wiring. CIDRW System User’s Manual 27 SECTION 2 I...
https://www.fa.omron.co.jp/data_pdf/mnu/z218-e1-01a_v640-ham12_hs62.pdf
...on cable for Sensor Head DC24 V (±10 %) Recommended part (1) If the number of connections is 1: S82K-01524 (DC24 V, 0.6 A) (2) If the number of connections is 2 to 3: S82K-05024 (DC2...
https://www.fa.omron.co.jp/data_pdf/mnu/z236-e1-08_zs-hl.pdf
...⚍ S1˖䚼⌟䆩ᓔ݇/Ѧ䫕ԡᓔ݇˄ϡ㽕∖ᓔ݇ᯊ䖲ࠄ0V˅ S2˖㘨䫕ԡᓔ݇ KM1ǃKM2˖ᏺ᳝ᔎࠊᇐ⚍(G7SA)ⱘᅝܼ㒻⬉఼⺕ᗻ㾺఼ M˖3Ⳍ⬉ᴎ E1˖DC24V⬉⑤(S82K) 䗮ֵ㒓䏃(+) ˄♄㡆˅ 䗮ֵ㒓䏃(−) ˄㉝㡆˅ ሣ㬑ሣ㬑 ᠧᓔ 嗻㪱㡆嗼0V嗻㑶㡆嗼 ⌟䆩䕧ܹ嗻咥㡆嗼...
https://www.fa.omron.com.cn/data_pdf/cat/f3sr-b_ca_c_10_1.pdf
...h forcibly-guided contact (G7SA) or magnetic contactor M :3-phase motor E1 :24VDC power supply (S82K) Open •External relay monitoring function is used. •Operating range setting: Short F3SR-B ...
https://www.fa.omron.com.cn/data_pdf/cat/f3sr-b_f089-e1_10_1_csm2138.pdf
...䆱 G9SA-300-SC 应用示例 ●仅连接安全光幕(自动复位) ཌ䜞䈀ᯣ S1φ KM1ૂKM2φ Mφ E1φ ཌ䜞⎁䈋ᔶީ ᙝ䀜ಞ 3⭫ᵰ DC24V⭫Ⓠ(S82K) ᰬᓅഴ OSSD1 OSSD2 Vcc GND 13 23 33 X1 Y1 H1 T12 T11 A2 A1 J1 C1 G1 D1 D2 E2 E1 ...
https://www.fa.omron.com.cn/data_pdf/cat/g9sa-300-sc_ds_c_3_2.pdf
...External test switch KM1 and KM2: Magnetic Contactors M: 3-phase motor E1: 24-VDC Power Supply (S82K) Timing Chart OSSD1 OSSD2 Vcc GND 13 23 33 X1 Y1 H1 T12 T11 A2 A1 J1 C1 G1 D1 D2 E2 E1 T21...
https://www.fa.omron.com.cn/data_pdf/cat/g9sa-300-sc_ds_e_3_2_csm1284.pdf
...⭻䙐 䱱ᯣ K1ૂK2 (NC) K1ૂK2 (NO) KM1ૂKM2 (NC) KM1ૂKM2 (NO) ᆿޞՖಞ གྷփᔶީ ᙝ⛯ G3Jരᘷ⛯(G3J) 3⭫ᵰ DC24V⭫Ⓠ(S82K) F3SJ-Aφ S1φ KM1ૂKM2φ KM3φ Mφ E1φ *മѝᡰ⽪F3SJ-A䖵ࣙ䗃ࠪ㓯⭘Ҿ᳇ONDŽ G9SA 14 400-820-4535 www....
https://www.fa.omron.com.cn/data_pdf/cat/g9sa_ds_c_10_13.pdf
...2 (NC) K1ૂK2 (NO) KM1ૂKM2 (NC) KM1ૂKM2 (NO) F3SJ-AφᆿޞՖಞ S1φགྷփᔶީ KM1ૂKM2φᙝ⛯ Mφ3⭫ᵰ E1φDC24V⭫Ⓠ(S82K) O SS D 1 δ 㔵㢨 ε O SS D 2 δ ⲳ㢨 ε F3SJ-A RS-485(A)δ⚦㢨ε RS-485(B)δ㊿㢨ε ኅ㭳ኅ㭳 0V δ 㬓㢨...
...险丝(客户提供)。 (只有电源满足2类电路的输出特性要求或者由UL 508所定义的电压电流限制时才不需要保险丝。 )(例如,S82K和S8VS) *5.使用缺省设置时禁用测试输入。 若要使用测试输入,将PDM连接到受...
https://www.fa.omron.com.cn/data_pdf/cat/ms4800_ca_c_7_4.pdf