Primary Contents

IAグローバル検索結果

国/地域選択

IAグローバル検索
結果 4061 - 408055544
E3S-GS3E4 2M | OMRON Industrial Automation

...umption 40 mA max. Control output NPN voltage output 24 VDC max. 80 mA max. Residual voltage: 2 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...

https://www.ia.omron.com/product/item/21340/

E3S-GS3E4 5M | OMRON Industrial Automation

...umption 40 mA max. Control output NPN voltage output 24 VDC max. 80 mA max. Residual voltage: 2 V max. Operation mode Light-ON/Dark-ON selectable Protective circuit Output short-circuit prote...

https://www.ia.omron.com/product/item/21341/

E2EC-CR5C15 2M | OMRON Industrial Automation

...ntrol output (Switching capacity) 100 mA max. (30 VDC max.) Control output (Residual voltage) 1 V max. (Load current 100 mA with cable length of 2 m) Indicator Detection indicator (red) Opera...

https://www.ia.omron.com/product/item/21360/

E2K-L13MC1 2M | OMRON Industrial Automation

...n collector Control output (Switching capacity) 100 mA max. Control output (Residual voltage) 1 V max. (Load current 100 mA with cable length of 2 m) Indicator Detection indicator (orange) Op...

https://www.ia.omron.com/product/item/21377/

E2K-L26MC1 2M | OMRON Industrial Automation

...n collector Control output (Switching capacity) 100 mA max. Control output (Residual voltage) 1 V max. (Load current 100 mA with cable length of 2 m) Indicator Detection indicator (orange) Op...

https://www.ia.omron.com/product/item/21378/

TL-L100-7 1M | OMRON Industrial Automation

...t type) NPN Control output (Switching capacity) 200 mA max. Control output (Residual voltage) 1 V max. Indicator Operation indicator (red) Operation mode NO Protective circuit Reverse polarit...

https://www.ia.omron.com/product/item/21385/

EE-SPX302-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2170/

EE-SPX304-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2172/

EE-SPX305-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2174/

EE-SPX306-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2176/

EE-SPX402-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2179/

EE-SPX404-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2181/

EE-SPX405-W2A 2M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 80 mA max. Residual voltage at 80 mA load current: 1.0 V max. at 10 mA load current: 0.4 V max. Response frequency elements 500 Hz min. Illum...

https://www.ia.omron.com/product/item/2183/

EJ1N-TC2A-CNB | OMRON Industrial Automation

...point Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. No-contact input: ON: Residual voltage 1.5 V max., OFF: Leakage current 0.1 mA max. Short-circuit current: Approx. 4 mA per point Sampling...

https://www.ia.omron.com/product/item/22166/

EJ1N-TC2A-QNHB | OMRON Industrial Automation

...point Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. No-contact input: ON: Residual voltage 1.5 V max., OFF: Leakage current 0.1 mA max. Short-circuit current: Approx. 4 mA per point Sampling...

https://www.ia.omron.com/product/item/22167/

EJ1N-TC2B-CNB | OMRON Industrial Automation

...point Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. No-contact input: ON: Residual voltage 1.5 V max., OFF: Leakage current 0.1 mA max. Short-circuit current: Approx. 4 mA per point Sampling...

https://www.ia.omron.com/product/item/22168/

EJ1N-TC2B-QNHB | OMRON Industrial Automation

...point Contact input: ON: 1 kΩ max., OFF: 100 kΩ min. No-contact input: ON: Residual voltage 1.5 V max., OFF: Leakage current 0.1 mA max. Short-circuit current: Approx. 4 mA per point Sampling...

https://www.ia.omron.com/product/item/22169/

EE-SX953P-R 1M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 0.7 V max. at 5 mA load current: 0.4 V max. Protection circuits Output short-cut protectio...

https://www.ia.omron.com/product/item/2280/

EE-SX953P-W 1M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 0.7 V max. at 5 mA load current: 0.4 V max. Protection circuits Output short-cut protectio...

https://www.ia.omron.com/product/item/2281/

EE-SX954P-W 1M | OMRON Industrial Automation

...r supply voltage 5 to 24 VDC Load curren 50 mA max. Residual voltage at 50 mA load current: 0.7 V max. at 5 mA load current: 0.4 V max. Protection circuits Output short-cut protectio...

https://www.ia.omron.com/product/item/2285/