IAグローバル検索 |
...Setting number of unused axes Not supported Not supported Supported Supported Supported Setting CW/CCW pulse output direction Not supported Not supported Not supported Supported Supported Set...
https://www.fa.omron.com.cn/data_pdf/mnu/w376-e1-08_cs1w_nc.pdf
... for (3) will be the same as for (1). Origin Search Method Setting Description Search direction CW Origin search is executed in the CW direction. Detection method Methd 0 Reads the f...
https://www.fa.omron.com.cn/data_pdf/mnu/w461-e1-06_cp1l_cp1e.pdf
...I/O模块型号。 ) 普通输出---最多12点(每个脉冲I/O模块6点) 脉冲输出最多4点(每个脉冲I/O模块2点) 输出方式:CW/CCW或脉冲+方向(输出方式取决于I/O配线和梯形图中使用的指令。 ) 输出频率:1pps~100kpps(...
...- 12 max. (6 per Pulse I/O Module) Pulse outputs 4 max. (2 per Pulse I/O Module) Output method: CW/CCW or pulse + direction (The method is determined by the I/O wiring and the instructions us...
https://www.fa.omron.com.cn/data_pdf/mnu/w472-e1-16_cj2h-cpu6_eip_cj2m-cpu.pdf
...77 ---脉冲输出0的当前值(PV) 包含对应脉冲输出端口的脉冲输出数。 8000 0000~7FFF FFFF Hex(-2,147,483,648~2,147,483,647) 当脉冲在CW方向输出时,每个脉冲的当前值(PV)递增1。 当脉冲在CCW方向输出时...
...Target frequency: 500 Hz Pulse output 0 Stop pulse output (Not used.) Pulse + Direction output, CW, Continuous Mode 2 Instructions 2-330 CP1E/CP2E CPU Unit Instructions Reference Manual(W483)...
https://www.fa.omron.com.cn/data_pdf/mnu/w483-e1-08_cp1e_cp2e.pdf
...ultiplication x4 Phase A Phase B 123456789101112 11109876543210 123 123456 543210 210 Count up (CW) Count down (CCW) 3-15 3 Operation and Configuration CJ-series High-speed Counter Units Oper...
https://www.fa.omron.com.cn/data_pdf/mnu/w492-e1-04_cj1w-ct021.pdf
... 8-6-1 NX-PG0112 Terminal Block Arrangement Terminal No. Symbol I/O Name A1 A O Pulse output A (CW/PLS) A2 IOV O Pulse output, 24 V A3 O0 O External output 0 A4 IOV O External output, 24 V A5...
https://www.fa.omron.com.cn/data_pdf/mnu/w524-e1-10_nx-ec0_ecs_pg.pdf
...to the end effector . Axis Coordinate System for Axis A3: Rotation direction --- You can select CW or CCW. Axis Coordinate System for Axis A0: Initial angle LREAL The angle of arm 1 in its in...
https://www.fa.omron.com.cn/data_pdf/mnu/w539-e1-08_nj501-4500_4400_4320_4310_4300.pdf
...ions 9-56 NY-series Industrial Panel PC / Industrial Box PC Motion Control User's Manual (W559) CW CCW CW : Clockwise rotation CCW : Counterclockwise rotation Y coordinate X coordina...
https://www.fa.omron.com.cn/data_pdf/mnu/w559-e1-07_ny532_ny512.pdf
...ast Decode Modulation Decodability Defects The 6 other parameters reported are: Total CW Data CW Erasures Corrections Row Height Structure Stacked Scan Reflectanc...
https://www.omron-ap.co.in/data_pdf/mnu/84-9310001-02-g_lvs-95.pdf
...ntrast 1.6 41% Corrections 0 CTR (Clock Track Regularity) 4.0 CTD (Clock Track Damage) 4.0 Data CW 12 Date and Time 01-Jun-2007 11:28 local; 01-Jun-2007 15:28 GMT Decodability 0.0 0% Decode F...
https://www.omron-ap.co.in/data_pdf/mnu/84-9310006-02-f_lvs-95.pdf
...ls. 1 Select the motor's rotation direction for positive commands in the Motor Rotation area. • CW (Clockwise) • CCW (Counterclockwise) 2 When you transfer the selected settings to the Drive,...
https://www.omron-ap.co.in/data_pdf/mnu/i589-e1-12_sysmac-se2___.pdf
...3[0].Chan[x].EncCtrl Set the decoding method of the encoder. In this manual, quadruple AB-phase CW decoding is set. *32 Motor[x].PosSf, Motor[x].Pos2Sf Specify the conversion factor between t...
https://www.omron-ap.co.in/data_pdf/mnu/o052-e1-02_ck_m_ck3w.pdf
...ents. Counter Input A A Incremental encoder Input B B Input Z Z (Reset input) Forward rotation (CW) Reverse rotation (CCW) Phase A Phase B 1 2 3 2 1 0 Multiplication x1 1 2 3 4 5 6 5 4 9 10 1...
https://www.omron-ap.co.in/data_pdf/mnu/w401-e1-05_cj1w-ct021.pdf
...NC IOV NC I1 IOV IOG I/O O O O O --I O O I/O O O --O --I O O Name Pulse output A (CW/PLS) Pulse output, 24 V External output 0 External output, 24 V Not used. External input 0 Sensor power su...
https://www.omron-ap.co.in/data_pdf/mnu/w524-e1-10_nx-ec0_ecs_pg.pdf
...ast Decode Modulation Decodability Defects The 6 other parameters reported are: Total CW Data CW Erasures Corrections Row Height Structure Stacked Scan Reflectanc...
https://www.omron-ap.co.nz/data_pdf/mnu/84-9310001-02-g_lvs-95.pdf
...ntrast 1.6 41% Corrections 0 CTR (Clock Track Regularity) 4.0 CTD (Clock Track Damage) 4.0 Data CW 12 Date and Time 01-Jun-2007 11:28 local; 01-Jun-2007 15:28 GMT Decodability 0.0 0% Decode F...
https://www.omron-ap.co.nz/data_pdf/mnu/84-9310006-02-f_lvs-95.pdf
...ls. 1 Select the motor's rotation direction for positive commands in the Motor Rotation area. • CW (Clockwise) • CCW (Counterclockwise) 2 When you transfer the selected settings to the Drive,...
https://www.omron-ap.co.nz/data_pdf/mnu/i589-e1-12_sysmac-se2___.pdf
...ents. Counter Input A A Incremental encoder Input B B Input Z Z (Reset input) Forward rotation (CW) Reverse rotation (CCW) Phase A Phase B 1 2 3 2 1 0 Multiplication x1 1 2 3 4 5 6 5 4 9 10 1...
https://www.omron-ap.co.nz/data_pdf/mnu/w401-e1-05_cj1w-ct021.pdf