IAグローバル検索 |
...s A and B output must be set higher only by a value equivalent to the drop in forward voltages (VF) of diodes D1 and D2. • Power loss occurs equivalent to the Power Supply output current (IOU...
https://www.omron-ap.com.my/data_pdf/cat/s8fs-c_t062-e1_4_1_csm1045833.pdf
...hould be set higher only by a value equivalent to the drop in diode D1 and D2 forward voltages (VF). In addition, since power loss occurs resulting from power supply output current (IOUT) × d...
https://www.omron-ap.com.my/data_pdf/cat/s8jx_t041-e1_20_5_csm2005.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com.my/data_pdf/cat/s8vk-t_t061-e1_10_5_csm1021435.pdf
...output voltage setting of Power Supply A and Power Supply B by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com.my/data_pdf/cat/s8vs_t026-e1_8_1_csm2022.pdf
...later or later or later 0.slr Visual Feedback Alignment Library SYSMAC -XR018 Ver.1.0 OmronLib _VF_Align Ver.1.10 ment_V1_ or later 0.slr RFID Communications Library SYSMAC -XR019 Ver.1.0 Omr...
https://www.omron-ap.com.my/data_pdf/cat/sysmac-xr____p102-e1_8_8_csm1047496.pdf
...Standard Flexible Encoder cable R88AStandard Flexible CR1AC CR1ACF CR1BN CR1BNF CR1BV CR1BVF CR1BN CR1BNF CR1BV CR1BVF CR1BN CR1BNF CR1BV CR1BVF CR1BN CR1BNF...
https://www.omron-ap.com.my/data_pdf/mnu/i868-e1-02_r88m-1__r88d-1sn__r88m-k__r88d-kn_-ect.pdf
... Re-confirmation is required for setting. A044 0: Constant torque characteristics (VC) AA121 0: VF control (Constant torque) If to set the "0: Constant torque characteristics (VC)" and set th...
https://www.omron-ap.com.my/data_pdf/mnu/i922-e1-03_3g3rx2_3g3rx.pdf
...urrent of Unit with transistor inputs ION is obtained from the following formula. ION = (VCC–VR–VF) / RIN VF: Residual voltage of Transistor Input (Refer to page 351 for specificatio...
https://www.omron-ap.com.my/data_pdf/mnu/w266-e1-09_c200hw_cj1w_cqm1_srt1_srt2.pdf
... IOUT (max.) IOUT: Sensor control output (load current) ION: Slave ON current ION = (VCC – VR – VF)/RIN VF: RIN: Internal residual voltage of Slave Input impedance of Slave When ION ...
https://www.omron-ap.com.my/data_pdf/mnu/w347-e1-06_c200hw_cqm1-drt_drt1.pdf
...al • Overload Limit • Lock • Non-Stop Function at Momentary Power Interruption • Torque Limit • Vf Free Setting • Multi-Function Input Terminals • Multi-Function Output Setting • Analog Monit...
https://www.omron-ap.com.my/data_pdf/mnu/w453-e1-13_ws02-drvc1.pdf
...al • Overload Limit • Lock • Non-Stop Function at Momentary Power Interruption • Torque Limit • Vf Free Setting • Multi-Function Input Terminals • Multi-Function Output Setting • Analog Monit...
https://www.omron-ap.com.my/data_pdf/mnu/w453-e1-23_cx-drive.pdf
...OUT: Sensor control output (load current) ION: Communications Unit ON current ION = (VCC − VR − VF)/RIN VF: Internal residual voltage of a Communications Unit with DC Inputs RIN: Inp...
https://www.omron-ap.com.my/data_pdf/mnu/w455-e1-08_grt1.pdf
... := TRUE V0=Vconveyor Deceleration distance: Synchronization DDecel= (V0 * T5) / 2 Deceleration Vf=0 T5 Acceleration in X T Maximum Deceleration rate: DecMax= 2* (V0 / T5) T Jerk is automatic...
https://www.omron-ap.com.my/data_pdf/mnu/w539-e1-08_nj501-4500_4400_4320_4310_4300.pdf
... follows. XYθ Position (sPOSITION) Stores the XYθ coordinates. Variable name Data type OmronLib\VF_Alignment\sPOSITION *1. Description Valid range Unit STRUCT — — — X LREAL X coordinate Depen...
https://www.omron-ap.com.my/data_pdf/mnu/w608-e1-02_sysmac-xr018.pdf
...400 V: 3000-r/min Servomotors of 4 kW or more 1500-r/min Servomotors Flexible Cable R88A-CR1B VF The empty boxes in the model number are for the cable length. (6.0 mm dia.) Servo Drive side...
https://www.omron-ap.com.ph/data_pdf/cat/1s-51_i928-e1_2_1_csm1129313.pdf
...400 V: 3000-r/min Servomotors of 4 kW or more 1500-r/min Servomotors Flexible Cable R88A-CR1BVF The empty boxes in the model number are for the cable length. (6.0 mm dia.) Servo Drive side...
https://www.omron-ap.com.ph/data_pdf/cat/1s_series_i821-e1_10_11_csm1052864.pdf
...s A and B output must be set higher only by a value equivalent to the drop in forward voltages (VF) of diodes D1 and D2. • Power loss occurs equivalent to the Power Supply output current (IOU...
https://www.omron-ap.com.ph/data_pdf/cat/s8fs-c_t062-e1_4_1_csm1045833.pdf
...hould be set higher only by a value equivalent to the drop in diode D1 and D2 forward voltages (VF). In addition, since power loss occurs resulting from power supply output current (IOUT) × d...
https://www.omron-ap.com.ph/data_pdf/cat/s8jx_t041-e1_20_5_csm2005.pdf
...• Increase the output voltage setting of the Power Supplies by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...
https://www.omron-ap.com.ph/data_pdf/cat/s8vk-t_t061-e1_10_5_csm1021435.pdf
...output voltage setting of Power Supply A and Power Supply B by the drop in the forward voltage (VF) of diodes D1 and D2. Also, the diodes will cause a power loss equivalent to the Power Suppl...