PDFCSM_CJ1W-CRM21_DS_C_11_12 1 400-820-4535 www.fa.om...

...异常履历(取决于异常种类:以导致通信停止的严重异常为主) 抗干扰性能符合IEC61000-4-4标准2kV(施加至电源) 耐振动 10~61.2Hz单振幅0.1mm、61.2~150Hz加速度14.7m/s2 X、Y、Z各方向80分钟(...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-crm21_ds_c_11_12.pdf

PDFCSM_CJ1W-CRM21_DS_E_11_10 1 CJ-series CompoNet Mas...

...e immunity Conforms to IEC 61000-4-4 2 kV (applied to power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s 2 in X, Y, and Z ...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-crm21_ds_e_11_10_csm1634.pdf

PDFCSM_CJ1W-ID_IA_DS_E_11_13 1 CJ-series Input Units ...

...with wire gauges of AWG 28 to 24 (0.08 to 0.2 mm2). Use cable with external wire diameters of 1.61 mm max. Crimping Tools The following models are recommended for crimping tools and pressure-...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-id_ia_ds_e_11_13_csm1616.pdf

PDFCSM_CJ1W-MD_DS_E_9_13 1 CJ-series Mixed I/O Units ...

...with wire gauges of AWG 28 to 24 (0.08 to 0.2 mm2). Use cable with external wire diameters of 1.61 mm max. Crimping Tools The following models are recommended for crimping tools and pressure-...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-md_ds_e_9_13_csm1618.pdf

PDFCSM_CJ1W-OUTPUT_DS_E_8_14 1 CJ-series Output Units...

...with wire gauges of AWG 28 to 24 (0.08 to 0.2 mm2). Use cable with external wire diameters of 1.61 mm max. Crimping Tools The following models are recommended for crimping tools and pressure-...

https://www.fa.omron.com.cn/data_pdf/cat/cj1w-oc_oa_od_ds_e_8_14_csm1617.pdf

PDFCSM_CJ2M-CPU3__-CPU1_-MD21__DS_E_12_7

...ith wires sized between 28 and 24 AWG (0.2 to 0.08 mm2). Use a wire with an outer diameter of 1.61 mm max. Compatible Terminal Blocks Name OMRON model number Socket XG4M-4030 Stain Relief XG4...

https://www.fa.omron.com.cn/data_pdf/cat/cj2m-cpu3__-cpu1_-md21__ds_e_12_7_csm2201.pdf

PDF400-820-4535 www.fa.omron.com.cn免费

...M3或φ3.2孔推荐安装螺钉 =M3×16mm以上 9.5 30±0.1 注.也可进行导轨安装。 (顶视图) φ3.5孔 5-M3×8 78.5以下 61以下 35.5 39.5 48以下2 31以下 16以下 17.2 4 6 P2RFZ-05-E(1极) (指触保护结构) 5 1 4...

https://www.fa.omron.com.cn/data_pdf/cat/common_sockets_ds_c_5_12.pdf

PDFCSM_common_sockets_DS_E_6_10 1 Common Sockets

...-E *1 Approx. 46 g PT08 Approx. 11 g PT08QN Approx. 10.4 g PT08-0 *2 Approx. 8 g PTF11A Approx. 61 g PT11 Approx. 13 g PT11QN PT11-0 *2 Approx. 12.2 g PTF14A Approx. 77 g PTFZ-14-E *1 Approx....

https://www.fa.omron.com.cn/data_pdf/cat/common_sockets_ds_e_6_10_csm1819.pdf

PDFCompoNet Catalog

...e immunity Conforms to IEC 61000-4-4 2 kV (applied to power supply). Vibration resistance 10 to 61.2 Hz with single-amplitude of 0.1 mm, 61.2 to 150 Hz and 14.7 m/s2 in X, Y, and Z d...

https://www.fa.omron.com.cn/data_pdf/cat/crt1_crt1b_componet_p056-e1_17_10_csm2176.pdf

PDFProgrammable Controller CS1D Duplex System

...0BASE-TX, Auto-Negotiation 5 Power supply connector 0.07 W4S1-05D Programmable Controllers CS1D 61 „Controller Link Units Controller Link Units *1.Use the following special cable for shielded...

https://www.fa.omron.com.cn/data_pdf/cat/cs1d-cpu__s_bc082s_etn21d_r103-e1_9_23_csm1004122.pdf

PDF1 CSM_CS1W-EIP21_EIP21S_DS_E_7_9

...therNet/IP Unit. Network Configurator version 3.74a or higher is included with CX-One version 4.61 or higher. The Network Configurator provides the following functions for building, setting, ...

https://www.fa.omron.com.cn/data_pdf/cat/cs1w-eip21_eip21s_ds_e_7_9_csm1782.pdf

PDFCSM_CX-Designer_DS_E_5_11 1 FA Integrated Tool Pac...

...gner version 3.3 or higher is also required. To connect the NJ3 Controller, NS system version 8.61 or higher is required. CX-Designer version 3.4 or higher is also required. *1. Multi license...

https://www.fa.omron.com.cn/data_pdf/cat/cx-designer_ds_e_5_11_csm1000602.pdf

PDFCSM_CX-Programmer_DS_E_11_10 1 FA Integrated Tool ...

...M2C-S100C/110C CPM2C-S110C-DRT CQM1 CQM1-CPU11/21/41/42/43/44/45 CQM1H-series CQM1H-CPU11/21/51/61 CVM1/CV-series CV1000 CV1000-CPU01 (-V1) CV2000 CV2000-CPU01 (-V1) CV500 CV500-CPU01 (-V1) C...

https://www.fa.omron.com.cn/data_pdf/cat/cx-programmer_ds_e_11_10_csm2060.pdf

PDFCSM_CX-Protocol_DS_E_7_9 1 FA Integrated Tool Pack...

...Z/CPU85-Z C200HG-CPU33-Z/CPU43-Z/CPU53-Z/CPU63-Z C200HE-CPU32-Z/CPU42-Z CQM1H CQM1H-CPU11/21/51/61 Series Serial Communication I/O Unit CS CS1W-SCU21(-V1)/SCU31-V1/SCB21(-V1)/SCB41(-V1) CJ CJ...

https://www.fa.omron.com.cn/data_pdf/cat/cx-protocol_ds_e_7_9_csm2078.pdf

PDF接近传感器 E2B系列 All 372 Models 全机种·高品质·低价格

... 39 59 4 24 φ16.4 2Ѡ㍝ര㷰∃ ࣞ֒᤽⽰⚥ (哺㢨LEDθ4×90°) E2B-M18KN10-M1-□□/E2B-M18KN16-M1-□□ 24 M12×1 M18×1 61 81 4 2Ѡ㍝ര㷰∃ ࣞ֒᤽⽰⚥ (哺㢨LEDθ4×90°) E2B-M18LS05-M1-□□/E2B-M18LS08-M1-□□ 24 M12×1 M18×1...

https://www.fa.omron.com.cn/data_pdf/cat/d117-cn5-01c.pdf

PDFCSM_D4A-_N_DS_C_4_9 1 400-820-4535 www.fa.omron.co...

...A-3@06N D4A-3@07-HN D4A-3@07-VN D4A-3@08N D4A-4@06N D4A-4@07-HN D4A-4@07-VN D4A-4@08N 动作力OF最大19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N ...

https://www.fa.omron.com.cn/data_pdf/cat/d4a-_n_ds_c_4_9.pdf

PDFCSM_D4A-_N_DS_E_4_6 1 General-purpose Limit Switch...

...HN D4A-3@07-VN D4A-3@08N D4A-4@06N D4A-4@07-HN D4A-4@07-VN D4A-4@08N Operating force OF max. 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N 19.61 N ...

https://www.fa.omron.com.cn/data_pdf/cat/d4a-_n_ds_e_4_6_csm584.pdf

PDFCSM_D4BL_DS_E_10_7 1 Guard Lock Safety-door Switch...

... speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Holding force (Fzh) 7...

https://www.fa.omron.com.cn/data_pdf/cat/d4bl_ds_e_10_7_csm1241.pdf

PDFCSM_D4BS_DS_E_8_7 1 Safety-door Switch D4BS

...eed 0.1 m/s to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force *3 19.61 N min. (EN60947-5-1) Direct opening travel *3 20 mm min. (EN60947-5-1) Contact resistance 25...

https://www.fa.omron.com.cn/data_pdf/cat/d4bs_ds_e_8_7_csm1237.pdf

PDFCSM_D4JL_D4JL-SK40_DS_C_9_12 1 400-820-4535 www.fa...

...)能用作异名极。 D4JL-@PF@-@ 2NC/1NO+3NC 仅NC接点(11-12、21-22) 拥有经认证的强制断开构造()。 端子(41-12)和(51-22)、 (33-34)、(61-62)能用作异名极。 D4JL-@QF@-@ 3NC+2NC/1NO NC接点(11-12、21-22、...

https://www.fa.omron.com.cn/data_pdf/cat/d4jl_d4jl-sk40_ds_c_9_12.pdf